Log settings and save
6-1.
Log operation settings
You can configure the following settings by clicking "Options" from the "Log" menu.
・
Selection of USB port to connect the analyzer
・
Detailed settings for log operation
・
Specifying a temporary folder and setting regarding how to check the free space
<
Operation method
>
1.
Connection port setting
Select either the serial number (LE-650H2) or the serial number (LE-650H2-A) from the drop-down list.
2.
Log operation setup
Item
Meaning
・
Function
When the hardware
buffer becomes full
Stop log operation at once
The log operation stops when the buffer memory is full (default setting).
Continue log opperation as much as possible
When the buffer memory is full packets are discarded. When the buffer memory have
space again subsequent recording is resumed, but since the packets were discarded
when the buffer memory was full, the transaction structure may not be correct.
Data logging place
of log operation
start
Add to the log window opened now
Add new log data to the end of the current log and record it.
Open and record in a new log window
Open a new log window and log to it.
Clear the present log window and record newly
Erases all data recorded in the current log window and records a new log.
Limitation of log
data size
Log file size
When the specified log size is reached while logging, the logging operation is
automatically stopped or writing to the next file is started.
Files in Repeat mode
Specify the number of files to open when acquiring logs in repeat mode.
Record VBus
voltage/ current
with USB log
(*)
VBus voltage / current recording
(*)
When checked, the VBus voltage and current are recorded at the selected cycle
with the USB communication packet at the same time.
* This is a function after v1.3.0.0. It will not work on the analyzer whose license has expired.