-29-
2.8 Connect to the Target Devices
If the connector of either target device is Dsub
25 pin, use attached DSUB 25 pin monitor cable
(LE-25M1) to connect to the analyzer.
[ Connection of LE-25M1 ] ( )is the pin number .
Dsub25pin male Dsub25pin male Dsub25pin female
( 1 ) --------- ( 1 ) -------- ( 1 )
( 2 ) --------- ( 2 ) -------- ( 2 )
( 3 ) --------- ( 3 ) -------- ( 3 )
( 4 ) --------- ( 4 ) -------- ( 4 )
・
・
(connected to the same numerical pin )
・
( 24 ) --------- ( 24 ) ------- ( 24 )
( 25 ) --------- ( 25 ) ------- ( 25 )
If the connectors of both target devices are Dsub
9 pin, use attached DSUB 9 pin branch cable (LE-
009M2) and DSUB 25-9 conversion adapter to con-
nect to the analyzer.
[ Connection of LE-009M2 and DSUB25-9 adapter ]
( ) is the pin number.
DSUB25-9 adapter LE-009M2
Dsub25pin Dsub9pin Dsub9pin Dsub9pin
male male female female male
( 8 ) ------------- ( 1 ) ----------- ( 1 ) --------- ( 1 )
( 3 ) ------------- ( 2 ) ----------- ( 2 ) --------- ( 2 )
( 2 ) ------------- ( 3 ) ----------- ( 3 ) --------- ( 3 )
( 20 ) ------------- ( 4 ) ----------- ( 4 ) --------- ( 4 )
( 7 ) ------------- ( 5 ) ----------- ( 5 ) --------- ( 5 )
( 6 ) ------------- ( 6 ) ----------- ( 6 ) --------- ( 6 )
( 4 ) ------------- ( 7 ) ----------- ( 7 ) --------- ( 7 )
( 5 ) ------------- ( 8 ) ----------- ( 8 ) --------- ( 8 )
( 22 ) ------------- ( 9 ) ----------- ( 9 ) --------- ( 9 )
ڦ
For monitoring
Connect to RS-232
To measure RS-232C, select “RS-232C” from “
Interface
” -> “Measurement port”.
2.3 Measurement Port
ڦ
For Simulation
Connect analyzer and target device one by one. Connect as
following, concerning the specification of target device (DTE/
DCE) and RS-232C cable.
RS-232C CABLE
RS-232C Port
Dsub25
Dsub25
Either is Dsub 25
pin connector
MONITOR Cable
RS-232C Port
DSUB25-9
conversion
adapter
Both Dsub 9 pin
connector
Dsub9
MONITOR Cable
(for Dsub 9pin)
RS-232C Port
DTE device ---- Straight cable ---- Analyzer (DCE setting)
DCE device ---- Straight cable ---- Analyzer (DTE setting)
DTE device ---- Cross cable ---- Analyzer (DTE setting)
DCE device ---- Cross cable ---- Analyzer (DCE setting)