FACTORY DEFAULTS

MASTER PROGRAMMING CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123456
ENTRY CODE LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS
REQUEST-TO-EXIT OUTPUT RELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MAIN RELAY
ALARM SHUNT OUTPUT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
FORCED ENTRY OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  OUTPUT #3
DOOR AJAR OUTPUT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  OUTPUT #4
MAIN RELAY ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
AUXILIARY RELAY ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
SOLID STATE OUTPUT #3 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
SOLID STATE OUTPUT #4 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
DOOR SENSE/INHIBIT INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR SENSE
KEYPAD LOCKOUT OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
KEYPAD ACTIVE OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
BEEPER SOUNDS WHEN KEY PRESSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES
BEEPER SOUNDS DURING RELAY #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING RELAY #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING OUTPUT #3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING OUTPUT #4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
KEYPAD LOCKOUT COUNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3 TRIES BEFORE LOCKOUT
ANTI-PASSBACK TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO ANTI-PASSBACK
AUTO-RELOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ON

BASIC PROGRAMMING

When the AK-2W is in Programming Mode, both indicators will turn 
off until programming begins. After a programming option number 
is entered the yellow indicator will blink. This shows that the 
AK-2W is ready to accept the new programming data. After the 
new data entry is complete, the yellow indicator will fl ash while 
the data is being stored. The green indicator will light if the data 
is accepted. The red indicator will light if any programming data 
is entered incorrectly, and the command will have to be fully 
re-entered.

Entering Programming Mode

The 6-digit Master Programming Code (default = 123456) is used to enter 
Programming Mode.

Press:

  

# 9 #

 

Master Code

 

Master Code

 = the current 6-digit Master Programming Code

Exiting Programming Mode

Press: 

 

*

 

*

 

#

The red indicator will light after exiting Programming Mode.

 

NOTE: 

The AK-2W will automatically exit Programming Mode after two 

minutes of inactivity.

Re-entering a Command After a Mistake

If the red indicator lights, signaling an incorrect entry, or an incorrect key is 
pressed during programming, to clear the keypad and re-enter the command:

Press: 

 

*

 

9 #

Setting Entry Code Length 

Default: 4 digits

Press:

  

0 3

 

#

 

Length

 

#

Length

 = 1 - 6 for entry code length

 

NOTE: If the Entry Code Length is going to be changed from the factory 
default of four digits, make this change fi rst, before programming any 
entry codes.

Adding a New Entry Code

Press:

  

0 1 #

 

Code

 

#

 

Code

 

#

 

Relay

 

#

Code

 = The new entry code: 1-999999, depending on code length

Relay

 = Relay output entry code will activate:

1 = Main Relay    2 = Auxiliary Relay    

3

 = Both Relays

The yellow indicator will fl ash quickly while the AK-2W searches its memory for 
available space and duplicate entries. The green indicator will light when the new 
code is stored.
If the new entry code chosen is already being used for another entry code, the 
red indicator will light. A new 

unique

 code needs to be entered.

 

NOTE:

 Leading zeros (zeros before the code number, i.e. 0001) do not need 

to be entered when programming a new entry code. The AK-2W will internally 
add any zeros to fi ll all digits determined by the entry code length setting. 
Leading zeros 

will

 have to be entered by the user when entering their code 

to gain access.

Erasing a Single Entry Code

Press:

  

0 2 #

 

Code

 

#

 

Code

 

#

Code

 = The entry code to delete.

The yellow indicator will fl ash quickly while the AK-2W searches its 
memory for the code to erase. The green indicator will light when 
the code is erased.

Erasing All Entry Codes

  WARNING: PERFORMING THIS COMMAND WILL 

REMOVE ALL ENTRY CODES FROM THE MEMORY.

Press:

  

9 7 # 0 0 0 0 0 0 # 0 0 0 0 0 0 #

 

NOTE:

 The green indicator will light while the memory is being erased. This 

may take up to 15 seconds.

Changing the 6-Digit Master Programming Code

Press:

  

9 8 #

 

Master Code

 

#

 

Master Code

 

#

Master Code

 = The new 6-digit Master Programming Code

New master code: _____________________

PROGRAMMING OPTIONS

There are several AK-2W programming options. For most 
installations, the factory set default options are suffi cient. The 
keypad must be in Programming Mode to make these changes.

PROGRAMMING AK-2W TO HOLD THE OUTPUT

Linear’s AccessKey products have a programmable “Toggle Mode” 
available for each relay and solid-state output. When an output is 
programmed for Toggle Mode, the output alternates from OFF to 
ON 

or

 from ON to OFF each time it is activated.

The rules for a toggle output are:

• If the output is OFF, it will turn ON and stay on until the next 
activation.

• If the output is ON, it will turn OFF and stay off until the next 
activation.

Typical Programming

With the unit in Program Mode

, set the Auxiliary Relay (Relay #2) 

output to Toggle Mode using the following keystrokes:

Press:

  

2 2 #

 

9 9

 

#

22 = Programming 

S

tep; 99 = Toggle Mode

222162 B     IMAGE 6

Содержание WEATHER RESISTANT KEYLESS ENTRY SYSTEM AK-2W

Страница 1: ...87 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 222162 B IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AK 2W LINEAR P N 222162 B INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 SCALE...

Страница 2: ...try codes and programming even without power An internal jumper is provided to reset the master code The Main Relay has a 5 Amp capacity The Auxiliary Relay has a 1 Amp capacity Two solid state output...

Страница 3: ...1 12 24 VOLT AC OR DC POWER MAIN RELAY 5 AMPS 28 VDC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 2 TERMINAL BLOCK 1 AK 2W TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF...

Страница 4: ...ower beeper sound level is required before installing the keypad remove Jumper JP1 place the jumper block on one pin to save the jumper Hook the keypad assembly onto the mounting plate tab see Figure...

Страница 5: ...ute two wires from the switch to the keypad box Connect the door switch to the keypad s SENSE terminal TB1 8 and COM terminal TB1 7 If an inhibit switch or timer is going to be used for temporarily di...

Страница 6: ...Code Code Relay Code The new entry code 1 999999 depending on code length Relay Relay output entry code will activate 1 Main Relay 2 Auxiliary Relay 3 Both Relays The yellow indicator will flash quic...

Страница 7: ...ts which output activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxili...

Страница 8: ...Volts AC or DC Current 30 mA typical 150 mA maximum Outputs Main Relay Form C 5 Amps 28 Volts maximum Auxiliary Relay Form C 1 Amp 28 Volts maximum Solid state outputs Outputs 3 4 Short to common 100...

Отзывы: