1

COMPONENT LOCATIONS

WIRING DIAGRAM

222162 B     IMAGE 3

RED/GREEN
POWER/ACCE

SS

INDICATOR

YELLOW
"LOCKOUT"
INDICATOR

KEYPAD

S

OLID 

S

TATE

WHITE LED
DOWN LIGHT

MA

S

TER CODE

RE

S

ET JUMPER

(JP2)

TERMINAL
BLOCK #1
(TB1)

TERMINAL
BLOCK #2
(TB2)

BEEPER
LEVEL
JUMPER (JP1)

FACEPLATE

BEZEL

MOUNTING
PLATE

1 - AC OR DC

2 - AC OR DC

3

 - N.O.

4 - COM

5 - N.C.

6 - N.O.

7 - COM

8

 - N.C.

S

EN

S

E - 

8

COM - 7

REQUE

S

T-TO-EXIT - 6

EARTH GROUND - 5

OUTPUT #

3

 COM - 4

OUTPUT #

3

 - 

3

OUTPUT #4 - 2

OUTPUT #4 COM - 1

12-24 VOLT

AC OR DC

POWER

MAIN RELAY

5 AMP

S

 @

28 VDC MAX.

AUXILIARY

RELAY 1 AMP

@ 28 VDC MAX.

TERMINAL

BLOCK 2

TERMINAL

BLOCK 1

AK-2W TERMINALS

CAUTION

IF THE UNIT IS AC POWERED,

MAKE SURE THE SECONDARY OF THE

SYSTEM TRANSFORMER IS ISOLATED

FROM EARTH GROUND

OPTIONAL WIRING

REQUIRED WIRING

OTHER WIRING

NOTE

S

1. ALARM 

S

HUNT 

S

ET FOR AUXILIARY RELAY

2. TERMINAL BLOCK #2, TERMINAL 

8

 

S

ET FOR DOOR 

S

EN

S

E

GROUND

STAKE

N.C. DOOR

SWITCH

ALARM

CONTACT

TO ALARM

S

Y

S

TEM

POWER
SUPPLY

ELECTRIC

DOOR

STRIKE

AUXILIARY

OUTPUT

S

100 mA MAX.
TO COMMON

REQUEST

TO EXIT

BUTTON

TYPICAL DOOR INSTALLATION WIRING

Figure 1. Component Locations

Figure 2. Wiring Diagram

Содержание WEATHER RESISTANT KEYLESS ENTRY SYSTEM AK-2W

Страница 1: ...87 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 222162 B IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AK 2W LINEAR P N 222162 B INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 SCALE...

Страница 2: ...try codes and programming even without power An internal jumper is provided to reset the master code The Main Relay has a 5 Amp capacity The Auxiliary Relay has a 1 Amp capacity Two solid state output...

Страница 3: ...1 12 24 VOLT AC OR DC POWER MAIN RELAY 5 AMPS 28 VDC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 2 TERMINAL BLOCK 1 AK 2W TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF...

Страница 4: ...ower beeper sound level is required before installing the keypad remove Jumper JP1 place the jumper block on one pin to save the jumper Hook the keypad assembly onto the mounting plate tab see Figure...

Страница 5: ...ute two wires from the switch to the keypad box Connect the door switch to the keypad s SENSE terminal TB1 8 and COM terminal TB1 7 If an inhibit switch or timer is going to be used for temporarily di...

Страница 6: ...Code Code Relay Code The new entry code 1 999999 depending on code length Relay Relay output entry code will activate 1 Main Relay 2 Auxiliary Relay 3 Both Relays The yellow indicator will flash quic...

Страница 7: ...ts which output activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxili...

Страница 8: ...Volts AC or DC Current 30 mA typical 150 mA maximum Outputs Main Relay Form C 5 Amps 28 Volts maximum Auxiliary Relay Form C 1 Amp 28 Volts maximum Solid state outputs Outputs 3 4 Short to common 100...