PRODUCT DESCRIPTION

The PERS-3600 Console is a supervised wireless emergency reporting product designed for 
medical alert applications. The table-top Console provides “pushbutton” emergency assistance to 
anyone who desires additional security and peace of mind. For the visually impaired, each button 
on the Console is molded with braille characters to identify the button’s function.

 

The  Console  can  receive  signals  from  up  to  16  Linear  wireless  transmitters.  Activating  a 
transmitter causes the Console’s digital communicator to send the appropriate alarm report to the 
central monitoring station via the standard telephone network. In addition to the central station 
report, audible and visual indications occur and the alarm relay energizes during an emergency 
activation.
The emergency alarm can be triggered by the large HELP button on the top of the Console or with 
a wireless transmitter. The fire alarm can be triggered by a wireless smoke alarm.

ACTIVITY TIMER

The optional 

activity timer

 can be set for 8, 12 or 24 hour operation or disabled. The emergency 

alarm will trigger automatically if the time set elapses before an activity transmitter is triggered or 
the Console’s HOME button is pressed.

VOICE PROMPTS

To  simplify  operation,  the  Console  can  “speak”  to  the  subscriber  with  its  built-in  digitally 
synthesized voice. The Console will say “emergency”, “fire”, “timer done soon”, and other system 
operation, setup, and supervisory prompts from a 49 word vocabulary. If necessary, the voice 
option can be disabled.

AUDIO COMMUNICATIONS

The Console can perform 2-way voice activated (duplex), 2-way manual, and 1-way listen-only 
audio communications through the Console’s built-in high-sensitivity microphone and speaker. 
Communications with central station monitoring personnel starts after an alarm. Communications 
can also be started without any subscriber action by calling the Console twice from any telephone 
and keying in a four digit password.

REMINDER MESSAGES

As a special feature, the PERS-3600 Console can record and play up to approximately eight 15-
second audio reminder messages. The reminder messages can be used to help the subscriber 
remember to take medications, call someone, get ready for an appointment, etc. Each message 
is  controlled  by  a  real  time  clock  and  can  be  programmed  via  the  RA-2400  software  to  play 
daily, every other day, weekly, or monthly. Reminder messages are played and repeated in three-
minute intervals for either 15 or 30 minutes (programmable) until canceled. Messages can also 
be programmed for single-play.

BUILT-IN SPEAKERPHONE

The  Console  can  be  programmed  to  act  as  a  remote  controlled  “speakerphone”.  With  the 
speakerphone  mode  enabled,  the  Console  will  monitor  the  telephone  line  for  an  incoming 
call. Activating any emergency transmitter (or the Console’s HELP button) while the telephone 
is  ringing  will  cause  the  Console  to  seize  the  line  and  begin  speakerphone  communications. 
Activating any emergency transmitter (or HELP button) during the call will disconnect the line. The 
Console will auto-disconnect after 15, 30, or 60 minutes (programmable).

TRANSMITTER SUPERVISION

Supervised transmitters regularly send status reports to the Console and low battery reports when 
their batteries are low. When the Console receives a low battery report, the STATUS indicator 
blinks. If the Console fails to receive a status report from a transmitter for a period of 24 hours, 
the STATUS indicator will light. All supervisory conditions can sound a local annunciation and be 
reported to the central station (optional through programming).

DIGITAL COMMUNICATOR

The  Console’s  digital  communicator  can  route  calls  to  three  telephone  numbers:  primary, 
secondary, and supervisory. General reporting codes and individual sensor reporting codes are 
programmable for the 4x2 format. Alternately, Ademco Contact ID format can be selected. The 
telephone line is constantly monitored, line failure and restoral will be locally announced by the 
Console (optional through programming).

POWER SUPPLY

Powered by a low voltage plug-in transformer, the Console has provisions for a rechargeable 
backup battery for operation during AC power outages. A power switch allows for out-of-service 
storage of the Console without discharge of the battery. The battery is recharged by the Console, 
even if the POWER switch is off (as long as the transformer is plugged in). If the backup battery 
becomes  low,  the  POWER  light  will  flash  and  the  condition  can  be  reported  to  the  central 
station.

PROGRAMMING

The Console is programmed using the RA-2400 remote access software (available on CD and 
at Linear’s website: www.linearcorp.com). Refer to the software’s detailed instruction manual and 
built-in help file for programming details.

OPERATION SUMMARY

A variety of Linear’s supervised DXS and non-supervised DX format transmitters can be 
used with the Console. Transmitters can be assigned to the following three functions:

EMERGENCY

Portable,  supervised  and  non-supervised,  pendant,  belt-clip,  or  wristband  type  transmitters 
(Models  DXT-41,  DXT-42,  DXT-61A,  DXS-21,  DXS-23,  DXS-62,  DXS-63)  and  stationary, 
supervised Model DXS-31 transmitters are used for medical alert applications. When a medical 
alert transmitter is triggered, the Console announces the emergency alarm and an emergency 
report is sent to the central station. The emergency alarm can also be triggered by pressing the 
Console’s HELP button.

FIRE

Supervised Model DXS-72 wireless photoelectric smoke alarm triggers the fire alarm. When the 
fire  alarm  is  activated,  the  Console  announces  the  fire  alarm  and  a  fire  report  is  sent  to  the 
central station.

ACTIVITY

Supervised, switch or motion triggered transmitters (Models DXS-31/DXS-32 and DXS-54) can be 
used for ensuring human activity. The DXS-54 motion detector will monitor room activity. The DXS-
31 and DXS-32 transmitters can be wired to a pushbutton or switch for manual activity monitoring. 
As long as a signal is received at least once every 8, 12, or 24 hours (programmable) an alarm 
will 

not

 

be triggered. 15 minutes before the programmed time expires, the HOME indicator will 

start blinking and the Console will announce every ten seconds that the timer will run out soon. 
The activity timer can be reset with a signal from one of the activity transmitters or by pressing 
the HOME button on the Console. Failure to reset the activity timer within the programmed time 
period will trigger the Console’s emergency alarm and send an inactivity report to the central 
station. The activity timer can be turned on or off at the Console or through programming.

AUTOMATIC FULL SYSTEM TEST

The Console can be programmed to perform a full system test daily, weekly, or monthly. The 
automatic full system test can also be disabled. As long as all system components are operational, 
the system test report will be sent at the programmed interval. The full system test report will NOT 
be sent if any system component (transmitter, Console, phone line) is not fully functional.

EMERGENCY

DXT-61A

DXS-21

DXS-23

DXT-41

DXT-42

FIRE

ACTIVITY

DXS-31

DXS-72

DXS-31/32

DXS-54

DXS-62

DXS-63

UP TO 16 TRANSMITTERS

TOTAL CAN BE USED WITH

EACH CONSOLE

NOTE: NOT A UL LISTED DEVICE

NOTE: COMPATIBILITY WITH THE PERS-3600 HAS NOT BEEN VERIFIED BY UL

CONTROL AREA FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
REAR SIDE AND BOTTOM FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
TELEPHONE CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
BACKUP BATTERY INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
TRANSFORMER INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
APPLY POWER - SELECT DIALING METHOD  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
TRANSMITTER INSTALLATION OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLING SINGLE TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLING MULTIPLE TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
TESTING TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ERASING TRANSMITTERS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
RECORDING REMINDER MESSAGES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
LOCAL PROGRAMMING WITH RA-2400  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ACTIVITY TIMER OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
AUDIO OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SPEAKERPHONE OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SUPERVISORY CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
OPTIONAL OUTPUT CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
NON-VOICE PROMPT BEEP LEGEND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
WIRELESS INSTALLATION TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
LINEAR LIMITED WARRANTY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

222626 A 

IMAGE 2

Содержание PERS-3600

Страница 1: ...392 0123 Toll Free FAX 800 468 1340 www linearcorp com INSTALLATION OPERATION INSTRUCTIONS BY BY PRINTER S INSTRUCTIONS INSTR INSTL PERS 3600 LINEAR P N 222626 A INK BLACK MATERIAL 20 LB MEAD BOND SI...

Страница 2: ...d The telephone line is constantly monitored line failure and restoral will be locally announced by the Console optional through programming POWER SUPPLY Powered by a low voltage plug in transformer t...

Страница 3: ...TIVITY TIMER IS OFF PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER ON USED IN TEST MODE TO RECORD AND PLAYBACK REMINDER MESSAGES HOME BUTTON COVER HIDES THE HOME BUTTON IF THE ACTIVITY TIMER IS NOT USED R...

Страница 4: ...RS BOTH BUTTONS MUST ALWAYS BE PRESSED TO ACTIVATE A DXS 63 TRANSMITTER ADDS ONE TRANSMITTER AT A TIME PRESS CANCEL BUTTON FOR 5 SECONDS CONSOLE ANNOUNCES THAT IT IS READY TO LEARN TRANSMITTERS 1 2 AC...

Страница 5: ...RESET ALL TRANSMITTERS ERASED 1 CAUTION ALL TRANSMITTERS WILL BE ERASED PRESS CANCEL TO RETURN TO STANDBY MODE THE CONSOLE WILL ANNOUNCE ITS STATUS THE CONSOLE WILL RETURN TO STANDBY MODE AUTOMATICALL...

Страница 6: ...DICATOR WILL LIGHT SHOWING THAT THE ACTIVITY TIMER IS ENABLED ACTIVITY TIMER RUNNING NOTE TO TURN THE ACTIVITY TIMER OFF PRESS THE HOME BUTTON FOR FIVE SECONDS THE SUBSCRIBER NEEDS TO PRESS THE HOME B...

Страница 7: ...LIDE INTO THE TERMINAL HOLE NOTE THE CONSOLE IS SHIPPED WITH REMOVABLE LABELS COVERING SOME OF THE REAR CONNECTIONS TERMINALS 4 5 HAVE A FACTORY INSTALLED JUMPER DO NOT REMOVE UNLESS USING A UL LISTED...

Страница 8: ...CURRENT 190 mA BACKUP OPERATION DURATION 30 HOURS MINIMUM BATTERY LIFE EXPECTED 3 YEARS BACKUP SUPPLY OPERATING CURRENT 40 mA BATTERY FUSE 1 AMP TYPE 2AG RF CHARACTERISTICS RECEIVER TYPE DUAL DIVERSI...