background image

2

Contents

Introduction

The Model AE-500 Telephone Entry & Access Control System is designed 
for use as a primary access control device for gated communities, 
parking garages, offi ce buildings, apartments, dormitories, hotels/motels, 
commercial buildings and recreational facilities with up to 250 residents 
or users.
Housed in a locked, rugged stainless steel faced enclosure, the AE-500 
features a side-lit 12-key telephone style keypad with bright, easy-to-
read graphics, a backlit two-line directory display with a programmable 
welcome message, a built-in microphone, and speaker.
The two relay output channels can be programmed to control electric 
door strikes, magnetic locks, door & gate operators, or barrier gates.
The system utilizes hands-free, full duplex telephone communications 
between visitors and residents for granting access.
The system can be programmed locally using the keypad, remotely with 
a touch tone telephone, or remotely using a computer equipped with a 
modem and a web browser.
Before starting the installation, read and understand these instructions. 
Become familiar with the illustrations and wiring diagrams. They will be a 
guide to installing the system in an effi cient and professional manner.

Operation

In a typical installation, the unit’s memory would be programmed with 
each resident’s name and directory code number. Arriving visitors would 
use the keypad on the AE-500 to view the directory names and directory 
number for the desired resident. Upon entering the directory number, 
the AE-500 will automatically dial the resident’s telephone number and 
establish two-way voice communication between the visitor and the 
resident. The resident will then have the option to grant or deny access to 
the visitor by pressing a digit on their telephone.
In addition to the telephone entry, the AE-500 can grant access using 
entry codes (up to 500 entry codes) at the local or remote keypad. Interior 
and exterior remote keypads are available.
Block coded and single enrolled MegaCode® transmitters (up to a total 
of 1000 transmitters) can be used to gain access through the AE-500’s 
built-in radio receiver. Each transmitter can be individually deactivated or 
reactivated. In addition, a single enrolled transmitter can be deleted.

Hardware Features

  BUILT-IN RADIO RECEIVER

Variable gain, high-sensitivity receiver for wireless access media

  TWO FORM “C” (N.O. & N.C) RELAYS

Each relay has 3-amp @ 30-volt rating

 REQUEST-TO-EXIT INPUTS

Activates the access device for exiting using a hardwired switch

  POSTAL SWITCH OPTION

Cabinet supports mounting a standard U.S.P.S. postal switch for mail carrier access

✓ 

COLOR CAMERA OPTION

Cabinet supports mounting of a Linear color camera.

 SENSING INPUT

For sensing door position to control door-ajar and alarm features, or for access inhibit timer

 BUILT-IN ANNUNCIATOR

Programmable for beeps during output activations and chirps during keystrokes

 BUILT-IN MODEM

No add-on modem required for telephone communications with system

  MULTIPLE UNIT SUPPORT

Up to seven AE-500 units can be connected on the same telephone line

  REMOTE KEYPAD SUPPORT

The system supports one Linear remote interior or exterior keypad

Software Highlights

 LOCALLY PROGRAMMABLE

All programming can be performed from the local keypad

  REMOTE TELEPHONE PROGRAMMING

All programming can be performed with a TouchTone™ telephone over the phone line

  REMOTE COMPUTER PROGRAMMING

No dedicated programmer required, web-style programming with a computer and a modem

  500 ENTRY CODES

Up to 500 entry codes can be used for gaining access

  2-6 DIGIT ENTRY CODE LENGTH

Entry code lengths can be customized for small or large installations

  250 RESIDENT DIRECTORY CAPACITY

Up to 250 residents can have directory numbers for telephone entry

  2-4 DIGIT DIRECTORY NUMBER LENGTH

Directory Number lengths can be customized for small or large installations

  500 TRANSMITTER CAPACITY

Up to 500 block coded Linear transmitters can be used for gaining access

  TRANSMITTER FACILITY CODE SUPPORT

Identifi es wireless access media by installation

  TWO INDEPENDENT RELAY CHANNELS

Each output’s action is programmable

  OBSTACLE TRANSMITTER SUPPORT

Compatible with Linear’s Model MGT transmitter

Remote Keypads

Two remote keypads are available to connect to the AE-500. One keypad 
can be used with each AE-500 unit. A remote keypad will activate Relay 
Channel “B”only. Relay Channel “A” can only be controlled by the AE-500 
Keypad.

AM-KP Exterior Keypad

The Model AM-KP is housed in a rugged cast 
aluminum enclosure designed for exterior 
installations. The keypad can be mounted to a 
pedestal or directly to a wall. A keylock secures the 
keypad to the mounting backplate.

AM-KPI Interior Keypad

The Model AM-KPI keypad is designed to be 
mounted indoors in a standard single-gang 
electrical box. Tamper resistant screws secure 
the keypad to its mounting plate. The die-cast 
keys are downlit with a white LED. The keypad 
is supplied with a satin-chrome bezel and three 
interchangeable colored bezels (white, ivory, & 
bronze) to customize the keypad appearance for 
the installation.

220793 F     IMAGE 2

Introduction ........................................ 2
Operation ............................................ 2
Hardware Features ............................. 2
Software Highlights ............................ 2
Remote Keypads ................................. 2
Feature Overview ................................ 3
Component Locations ......................... 4
Wiring Diagram ................................... 5
Important Mounting Requirements ...... 6
Entry System Mounting ....................... 7
Entry System Mounting (Continued) .... 8
Relay Output Wiring ............................ 9
Power, Battery, & Ground Wiring ........10
Optional Color CCTV Camera..............10
Telephone Wiring ............................... 11
Optional Radio Antenna ...................... 11
Optional Postal Lock ..........................12
Optional Remote Keypad ....................12
Programming with a Computer ..........13
Programming Over the Telephone ......14
Programming from the Local Keypad..14
Programming Reference .....................15
Factory Settings ................................15
Programming Notes ...........................15
Setting Up Multiple Units ...................16

Changing the Master Password ..........16
Resident Data Programming ..............17
Entry Code Programming ...................18
Wireless Transmitter Programming ....19
Wireless Transmitter Programming 
(Continued) ....................................... 20
System Options (Continued).............. 21
System Options (Continued).............. 22
System Options (Continued).............. 23
System Utilities ..................................24
System Adjustments ......................... 25
System Diagnostics .......................... 25
AE-500 Operation .............................. 26
Specifi cations ................................... 27
Dimension Drawing ........................... 27
Troubleshooting ................................ 27
Linear Limited Warranty .................... 28
FCC Notice ........................................ 28

*

5

6

7

8

9

0

#

1

2

3

4

AM-KP

AM-KPI

Содержание AE-500

Страница 1: ...760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com AE 500 Telephone Entry Access Control System Installation Instructions...

Страница 2: ...TIPLE UNIT SUPPORT Up to seven AE 500 units can be connected on the same telephone line REMOTE KEYPAD SUPPORT The system supports one Linear remote interior or exterior keypad Software Highlights LOCA...

Страница 3: ...ith any Internet browser on site using a separate phone line or off site The intuitive graphic display of each of the programming step is the preferred method to program the AE 500 Local Programming A...

Страница 4: ...OR POWER INDICATOR MAIN POWER SWITCH RECEIVER RANGE KNOB ANTENNA CONNECTOR MICROPHONE DISPLAY POSTAL LOCK MOUNTING PLATE SPEAKER KEYPAD LIGHTING CONNECTOR MICROPHONE CONNECTOR SPEAKER CONNECTOR JTAG U...

Страница 5: ...P EARTH GROUND RING ELECTRIC DOOR STRIKE RELAY RATING 3 AMPS 30 VOLTS AC DC MAXIMUM TELEPHONE JACK DOOR STRIKE POWER SUPPLY DOOR SENSE CONTACT CASE GROUND STUD NOTE OPTIONAL BACKUP BATTERY WILL REQUIR...

Страница 6: ...ted from the AE 500 NEVER MOUNT THE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE 500 is used to control a gate operator connected to a vehicular gate the unit MUST be mounted AT...

Страница 7: ...it board screws Note how the green ground wire lugs are connected with the upper left screw 3 Carefully remove the circuit board Hold it by the edges Set it aside in a safe place Reverse these steps t...

Страница 8: ...supplied 8 Replace the circuit board and plug in each wiring connector Be sure to replace the green ground wires Pedestal Mounting The cabinet can be mounted on a standard goose neck pedestal When mou...

Страница 9: ...ay Channel A connect the wires to the RTE A and GND terminals 4B To activate Relay Channel B connect the wires to the RTE B and GND terminals Sensing Input The sensing input connects to a door switch...

Страница 10: ...Company Alternately connect to a cold water pipe for the earth ground 1 Connect the wire from the earth ground to the AE 500 s CASE GROUND STUD NOTE The EARTH GROUND terminal is internally connected...

Страница 11: ...500 The kit contains a whip antenna connector and a 36 length of coax cable The antenna connector should be mounted on a metal surface using a 3 8 hole Two other models of antennas are compatible wit...

Страница 12: ...Exterior Keypad The Model AM KP is housed in a rugged cast aluminum enclosure designed for exterior installations The keypad can be mounted to a pedestal or directly to a wall A keylock secures the k...

Страница 13: ...ough the AE 500 s programming pages is similar to browsing through your favorite web site s pages Anyone familiar with the Internet will find programming the AE 500 with a computer very easy The AE 50...

Страница 14: ...m the telephone s keypad Refer to the following sections of this manual for programming step details When programming over the telephone each programming step consists of entering programming data usi...

Страница 15: ...Y LANGUAGE ENGLISH PPN 31 ENTRY CODE RELAY SELECTION RELAY CHANNELS A B PPN 31 ENTRY CODE USAGE LIMIT UNLIMITED PPN 44 TRANSMITTER BUTTON SETUP SINGLE BUTTON LEFT OR TOP LEFT BUTTON ACTIVATES RELAY CH...

Страница 16: ...2 3 When the New Connection Wizard asks for the Phone Number to Dial Step 7 in the Page 13 figure enter the common telephone number for the multi unit installation followed by four commas the unit num...

Страница 17: ...ying a Resident Once resident data has been set it can be modified to change a resident s name or telephone number 1 If not already in Programming Mode use the local keypad to enter the master passwor...

Страница 18: ...1 250 12 Press 13 Exit Programming Mode if all programming is complete Modifying an Entry Code Once entry codes have been set they can be modified to change the relay s to activate or the number of us...

Страница 19: ...nsmitter is assigned it will become active and ready to use 1 If not already in Programming Mode connect by telephone or use the local keypad Enter the master password and access programming 2 Press 3...

Страница 20: ...nately Relay Channel B can be used for alarm contact shunting obstacle sensing output or triggering audible alarms 1 Press 2 Enter a number for the Relay Channel B function Enter 0 for normal access c...

Страница 21: ...lephone or use the local keypad Enter the master password and access programming 2 Press 3 Select the status for the MGT transmitter Enter 1 to activate the transmitter Enter 0 to deactivate the trans...

Страница 22: ...ming is complete Speaker Chirp on Keystrokes The factory setting will cause the speaker to chirp when each key on the local keypad is pressed The speaker chirp can be turned off 1 If not already in Pr...

Страница 23: ...on 4 button transmitters activate Relay Channel B Top button on 2 or 4 button transmitters is disabled Lower left on 4 button transmitters is disabled Lower right on 4 button transmitters is disabled...

Страница 24: ...tch Relay Channel B Press to release Relay Channel A Press to release Relay Channel B 3 The display will show the unit number for three seconds 4 Exit Programming Mode if all programming is complete D...

Страница 25: ...ion When calling for technical assistance Linear s Technical Services Department may ask the installer to use these components to diagnose the system On board Indicators Eleven LED indicators are on t...

Страница 26: ...facilitate a faster search the directory search will begin in the middle The visitor can search forward or backward from there When the visitor finds the resident s directory number they enter it on...

Страница 27: ...n incoming call 1 Automatic telephone answer disabled 2 AE 500 telephone line trouble Entry code will not activate relay 1 Entry code not set up for proper relay Remote keypad does not work 1 Remote k...

Страница 28: ...tion Number RPA Contact Linear Technical Services at 1 800 421 1587 for an RPA and other important details FCC Notice Changes or modifications not expressly described in this manual or approved by the...

Отзывы: