background image

17

220793 F   IMAGE 17

Resident Data Programming

Up to 250 resident names and telephone numbers can be set. Each resident 
entry is assigned a directory number. The directory numbers are the numbers 
visitors enter to have the system call the residents.

 

NOTE:

 When entering resident names, programming the AE-500 from a 

computer is the preferred method. Refer to the “Programming from the 
Local Keypad” section of these instructions for details on alphanumeric 
entry from the keypad.

Changing the Directory Number Length

The factory setting for the directory number length is 3 digits. It can be set to 2, 
3, or 4 digits.

1.  If not already in Programming Mode, connect by telephone or use the 

local keypad. Enter the master password and access programming.

2. Press

 

 

 

3.  Enter the directory number length (2, 3, or 4).
4. Press 
5.  Exit Programming Mode if all programming is complete.

Adding a Resident

1.  If not already in Programming Mode use the local keypad to enter the 

master password and access programming.

2. Press

 

 

 

3.  Enter the directory number that will be displayed for the resident.
4. Press 

 

NOTE:

 To add the name using all capital letters, press 

 before entering 

the name.

5.  Enter the name of the resident to be displayed (up to 16 characters).
6. Press 
7.  Enter the resident’s telephone number (up to 12 digits).
8. Press 
9.  Exit Programming Mode if all programming is complete.

Modifying a Resident

Once resident data has been set, it can be modifi ed to change a resident’s name 
or telephone number.

1.  If not already in Programming Mode, use the local keypad to enter the 

master password and access programming.

2. Press

 

 

 

3.  Enter the resident’s directory number.
4. Press 

 

NOTE:

 To modify the name using all capital letters, press 

 before 

entering the name.

5.  Modify the name of the resident to be displayed (up to 16 characters), or 

to keep the name press 

 and skip to Step 6.

6. Press 
7.  Modify the resident’s telephone number (up to 12 digits) or skip to Step 8.
8. Press 
9.  Exit Programming Mode if all programming is complete.

Deleting a Resident

Residents can be deleted individually.

1.  If not already in Programming Mode, connect by telephone or use the 

local keypad. Enter the master password and access programming.

2. Press

 

 

 

3.  Enter the resident’s directory number.
4. Press 
5.  Enter the resident’s directory number again.
6. Press 
7.  Exit Programming Mode if all programming is complete.

PPN 02

02#LENGTH#

LENGTH = NUMBER (2-4) OF DIRECTORY NUMBER DIGITS

DIRECTORY NUMBER LENGTH

FACTORY SETTING: 3 DIGITS

PPN 21

DIR = DIRECTORY NUMBER FOR THE RESIDENT
NAME = THE RESIDENT'S NAME (UP TO 16 CHARACTERS)
PHONE = THE RESIDENT'S TELEPHONE NUMBER (UP TO 12 DIGITS)

ADDING A RESIDENT

21#DIR#NAME#PHONE#

PPN 22

DIR = DIRECTORY NUMBER FOR THE RESIDENT
NAME = THE RESIDENT'S NAME (UP TO 16 CHARACTERS)
PHONE = THE RESIDENT'S TELEPHONE NUMBER (UP TO 12 DIGITS)

MODIFYING A RESIDENT

22#DIR#NAME#PHONE#

PPN 23

23#DIR#DIR#

DIR = DIRECTORY NUMBER FOR THE RESIDENT

DELETING A RESIDENT

Содержание AE-500

Страница 1: ...760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com AE 500 Telephone Entry Access Control System Installation Instructions...

Страница 2: ...TIPLE UNIT SUPPORT Up to seven AE 500 units can be connected on the same telephone line REMOTE KEYPAD SUPPORT The system supports one Linear remote interior or exterior keypad Software Highlights LOCA...

Страница 3: ...ith any Internet browser on site using a separate phone line or off site The intuitive graphic display of each of the programming step is the preferred method to program the AE 500 Local Programming A...

Страница 4: ...OR POWER INDICATOR MAIN POWER SWITCH RECEIVER RANGE KNOB ANTENNA CONNECTOR MICROPHONE DISPLAY POSTAL LOCK MOUNTING PLATE SPEAKER KEYPAD LIGHTING CONNECTOR MICROPHONE CONNECTOR SPEAKER CONNECTOR JTAG U...

Страница 5: ...P EARTH GROUND RING ELECTRIC DOOR STRIKE RELAY RATING 3 AMPS 30 VOLTS AC DC MAXIMUM TELEPHONE JACK DOOR STRIKE POWER SUPPLY DOOR SENSE CONTACT CASE GROUND STUD NOTE OPTIONAL BACKUP BATTERY WILL REQUIR...

Страница 6: ...ted from the AE 500 NEVER MOUNT THE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE 500 is used to control a gate operator connected to a vehicular gate the unit MUST be mounted AT...

Страница 7: ...it board screws Note how the green ground wire lugs are connected with the upper left screw 3 Carefully remove the circuit board Hold it by the edges Set it aside in a safe place Reverse these steps t...

Страница 8: ...supplied 8 Replace the circuit board and plug in each wiring connector Be sure to replace the green ground wires Pedestal Mounting The cabinet can be mounted on a standard goose neck pedestal When mou...

Страница 9: ...ay Channel A connect the wires to the RTE A and GND terminals 4B To activate Relay Channel B connect the wires to the RTE B and GND terminals Sensing Input The sensing input connects to a door switch...

Страница 10: ...Company Alternately connect to a cold water pipe for the earth ground 1 Connect the wire from the earth ground to the AE 500 s CASE GROUND STUD NOTE The EARTH GROUND terminal is internally connected...

Страница 11: ...500 The kit contains a whip antenna connector and a 36 length of coax cable The antenna connector should be mounted on a metal surface using a 3 8 hole Two other models of antennas are compatible wit...

Страница 12: ...Exterior Keypad The Model AM KP is housed in a rugged cast aluminum enclosure designed for exterior installations The keypad can be mounted to a pedestal or directly to a wall A keylock secures the k...

Страница 13: ...ough the AE 500 s programming pages is similar to browsing through your favorite web site s pages Anyone familiar with the Internet will find programming the AE 500 with a computer very easy The AE 50...

Страница 14: ...m the telephone s keypad Refer to the following sections of this manual for programming step details When programming over the telephone each programming step consists of entering programming data usi...

Страница 15: ...Y LANGUAGE ENGLISH PPN 31 ENTRY CODE RELAY SELECTION RELAY CHANNELS A B PPN 31 ENTRY CODE USAGE LIMIT UNLIMITED PPN 44 TRANSMITTER BUTTON SETUP SINGLE BUTTON LEFT OR TOP LEFT BUTTON ACTIVATES RELAY CH...

Страница 16: ...2 3 When the New Connection Wizard asks for the Phone Number to Dial Step 7 in the Page 13 figure enter the common telephone number for the multi unit installation followed by four commas the unit num...

Страница 17: ...ying a Resident Once resident data has been set it can be modified to change a resident s name or telephone number 1 If not already in Programming Mode use the local keypad to enter the master passwor...

Страница 18: ...1 250 12 Press 13 Exit Programming Mode if all programming is complete Modifying an Entry Code Once entry codes have been set they can be modified to change the relay s to activate or the number of us...

Страница 19: ...nsmitter is assigned it will become active and ready to use 1 If not already in Programming Mode connect by telephone or use the local keypad Enter the master password and access programming 2 Press 3...

Страница 20: ...nately Relay Channel B can be used for alarm contact shunting obstacle sensing output or triggering audible alarms 1 Press 2 Enter a number for the Relay Channel B function Enter 0 for normal access c...

Страница 21: ...lephone or use the local keypad Enter the master password and access programming 2 Press 3 Select the status for the MGT transmitter Enter 1 to activate the transmitter Enter 0 to deactivate the trans...

Страница 22: ...ming is complete Speaker Chirp on Keystrokes The factory setting will cause the speaker to chirp when each key on the local keypad is pressed The speaker chirp can be turned off 1 If not already in Pr...

Страница 23: ...on 4 button transmitters activate Relay Channel B Top button on 2 or 4 button transmitters is disabled Lower left on 4 button transmitters is disabled Lower right on 4 button transmitters is disabled...

Страница 24: ...tch Relay Channel B Press to release Relay Channel A Press to release Relay Channel B 3 The display will show the unit number for three seconds 4 Exit Programming Mode if all programming is complete D...

Страница 25: ...ion When calling for technical assistance Linear s Technical Services Department may ask the installer to use these components to diagnose the system On board Indicators Eleven LED indicators are on t...

Страница 26: ...facilitate a faster search the directory search will begin in the middle The visitor can search forward or backward from there When the visitor finds the resident s directory number they enter it on...

Страница 27: ...n incoming call 1 Automatic telephone answer disabled 2 AE 500 telephone line trouble Entry code will not activate relay 1 Entry code not set up for proper relay Remote keypad does not work 1 Remote k...

Страница 28: ...tion Number RPA Contact Linear Technical Services at 1 800 421 1587 for an RPA and other important details FCC Notice Changes or modifications not expressly described in this manual or approved by the...

Отзывы: