CONTENTS

INTRODUCTION

Linear’s AccessKey is a digital keyless entry system
designed for access control applications. The keypad is
housed in a rugged cast aluminum enclosure that can be
mounted to a pedestal or bolted directly to a wall. The
die-cast keys have bright, easy-to-read yellow graphics.

Up to 480 entry codes, from 1 to 6 digits in length, can be
programmed. They can activate either, or both, of the relay
outputs. Relay #1 has a 5 Amp capacity. Relay #2 has a
1 Amp capacity.

Two LED indicators show the status of the entry system.
The left LED lights red to indicate power, then turns green
when access is granted. The right LED lights yellow when
the keypad is in “lockout” condition (from too many
incorrect code entries). The keypad’s courtesy light
illuminates the keys for two minutes after any key is pressed.
An internal sounder beeps when each key is pressed.

The DOOR SENSE/INHIBIT input can be used two ways.
If programmed for “door sense”, a switch on the door
detects forced entry or door ajar situations. If programmed
for “inhibit”, the input can be wired to a “service” switch or
automatic timer that will disable the Relay #1 when
required.

The REQUEST-TO-ENTER input can be wired to a
pushbutton or fire access keyswitch to provide codeless
entry for authorized personnel. The “anti-passback”
feature prevents using the same code twice before the
programmed time elapses.

The ALARM SHUNT output activates when access is
granted. This output can be wired to shunt alarm contacts
on the access door/gate to prevent triggering of an alarm
when authorized access occurs.

Two solid state outputs, capable of switching 100 mA to
common, are programmable to signal forced entry, door
ajar, lockout, alarm circuit shunting, request-to-enter, and
keypad active conditions. 

The AccessKey is powered from a 12-24 Volt AC or DC
source. Power can be obtained from the access device or
a separate power supply. The EEPROM memory retains
all entry codes and programming, even without power.

SPECIFICATIONS

MECHANICAL

Case dimensions: 4.00" W x 5.50" H x 3.00" D

ELECTRICAL

Voltage: 12-24 Volts AC or DC

 Current: 10 mA typical, 150 mA maximum

Outputs: Relay #1

Form “C” 5 Amps @ 24 Volts maximum

Relay #2
Form “C” 1 Amp @ 24 Volts maximum

Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA 
@ 24 VDC maximum

ENVIRONMENTAL

Temperature: -22°F to 149°F (-30°C to 65°C)

Humidity: 5% to 95% non-condensing

FEATURES

KEYPAD PROGRAMMABLE

480 ENTRY CODE CAPACITY

1-6 DIGIT ENTRY CODE LENGTH

4 INDEPENDENT OUTPUTS (TIMED/TOGGLED)

4 INDEPENDENT TIMERS

EACH ENTRY CODE CAN BE PROGRAMMED TO ACTIVATE EITHER OR
BOTH RELAYS

RELAY CONTACTS ARE FORM “C” (N.O. & N.C)

SOLID STATE OUTPUTS ARE OPEN COLLECTOR (SWITCH-TO-COMMON)

TWO LED INDICATORS

COURTESY LAMP

PIEZO SOUNDER

TIMED ANTI-PASSBACK (LAST 3 VALID ENTRIES)

KEYPAD LOCKOUT

TACTILE KEY FEEL

DOOR SENSE INPUT

INHIBIT INPUT

REQUEST-TO-ENTER INPUT

INTRODUCTION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
SPECIFICATIONS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
FEATURES  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
COMPONENT LOCATIONS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
WIRING DIAGRAM  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
INSTALLATION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
FACTORY DEFAULTS .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
BASIC PROGRAMMING  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
PROGRAMMING OPTIONS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
ACCESSKEY OPERATION .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  10
MANAGER’S ENTRY CODE LOG  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  11
LINEAR LIMITED WARRANTY  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  12
FCC NOTICE  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  12

2

Содержание AccessKey

Страница 1: ...ck 0001 Black 0001 Digital Keyless Entry System Installation and Programming Instructions 760 438 7000 FAX 760 438 7043 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp c...

Страница 2: ...This output can be wired to shunt alarm contacts on the access door gate to prevent triggering of an alarm when authorized access occurs Two solid state outputs capable of switching 100 mA to common...

Страница 3: ...ST TO ENTER EARTH GROUND N O COMMON N C OUTPUT 3 OUTPUT 4 N O COMMON N C COMMON GROUND ACCESSKEY GATE OPERATOR INHIBIT TIMER AUXILIARY POWER OPEN J4 1 2 3 4 5 6 J3 1 2 3 4 5 6 7 8 9 DOOR SENSE COMMON...

Страница 4: ...h from the gate so the user cannot touch the gate from the keypad WARNING TO AVOID SERIOUS INJURY OR DEATH MAKE SURE THAT THE UNIT IS FAR ENOUGH FROM THE GATE SO THAT THE USER CANNOT TOUCH THE GATE WH...

Страница 5: ...t terminals observe wiring polarity Route two wires between the door strike and the keypad Connect one of the door strike wires to the keypad s Relay 1 N O terminal Connect the other door strike wire...

Страница 6: ...g an incorrect entry or a wrong key is pressed during programming to clear the keypad and re enter the command Press 9 Setting Entry Code Length Default 4 digits Press 0 3 Length Length 1 6 for entry...

Страница 7: ...ondition on the input occurs before access is granted with an entry code or with the request to enter input a FORCED ENTRY output will occur If an open condition remains 60 seconds after a relay activ...

Страница 8: ...vation Press 4 2 Sound Sound 1 for Yes 0 for No Beep Sounds During Output 3 Default No Selects whether or not the keypad beeps during Output 3 activation Press 4 3 Sound Sound 1 for Yes 0 for No Beep...

Страница 9: ...ock the keypad using the keylock see Figure 9 REMOVE JUMPER JP1 TO REDUCE THE SOUND LEVEL OF THE BEEPER Figure 8 Removing Beeper Jumper HOOK KEYPAD ONTO BACKPLATE USE KEY TO LOCK KEYPAD Figure 9 Locki...

Страница 10: ...l turn green and the programmed relay will activate for the programmed time If the number of incorrect codes entered exceeds the keypad lockout count the yellow LED will light indicating that the keyp...

Страница 11: ...ANAGER S ENTRY CODE LOG NAME ADDRESS OR APARTMENT NUMBER ENTRY CODE RELAY NUMBER 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2...

Страница 12: ...t Linear Technical Services at 1 800 421 1587 for an RPA and other important details FCC NOTICE Changes or modifications not expressly described in this manual or approved by the manufacturer could vo...

Отзывы: