Linear AccessKey Скачать руководство пользователя страница 10

Black

0010

Black

0010

ACCESSKEY OPERATION

Users of the AccessKey have up to 40 seconds to
key in their entry code.

Up to eight seconds are allowed between each
keystroke.

All digits of the entry code must be entered.
Example: If the code is 0042, the user must enter
“0 0 4 2”.

If the wrong key is pressed, pressing the 

*

 

key

will reset the keypad. The correct code can then be
re-entered.

After a correct code is entered, the red LED will
turn green and the programmed relay will activate
for the programmed time.

If the number of incorrect codes entered exceeds
the keypad lockout count, the yellow LED will light,
indicating that the keypad is locked out. The
lockout will remain for one minute.

After a valid code has been entered, it will be
unusable until the anti-passback time expires.

USERS HAVE UP TO
40 SECONDS TO ENTER
THEIR COMPLETE CODE

PRESS STAR KEY TO
RESET KEYPAD IF THE
WRONG KEY IS PRESSED

RED LED TURNS
GREEN WHEN
ACCESS IS GRANTED

YELLOW LED WILL LIGHT 
DURING KEYPAD LOCKOUT IF 
TOO MANY INCORRECT CODES 
ARE ENTERED

Figure 10. Operating AccessKey

10

Содержание AccessKey

Страница 1: ...ck 0001 Black 0001 Digital Keyless Entry System Installation and Programming Instructions 760 438 7000 FAX 760 438 7043 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp c...

Страница 2: ...This output can be wired to shunt alarm contacts on the access door gate to prevent triggering of an alarm when authorized access occurs Two solid state outputs capable of switching 100 mA to common...

Страница 3: ...ST TO ENTER EARTH GROUND N O COMMON N C OUTPUT 3 OUTPUT 4 N O COMMON N C COMMON GROUND ACCESSKEY GATE OPERATOR INHIBIT TIMER AUXILIARY POWER OPEN J4 1 2 3 4 5 6 J3 1 2 3 4 5 6 7 8 9 DOOR SENSE COMMON...

Страница 4: ...h from the gate so the user cannot touch the gate from the keypad WARNING TO AVOID SERIOUS INJURY OR DEATH MAKE SURE THAT THE UNIT IS FAR ENOUGH FROM THE GATE SO THAT THE USER CANNOT TOUCH THE GATE WH...

Страница 5: ...t terminals observe wiring polarity Route two wires between the door strike and the keypad Connect one of the door strike wires to the keypad s Relay 1 N O terminal Connect the other door strike wire...

Страница 6: ...g an incorrect entry or a wrong key is pressed during programming to clear the keypad and re enter the command Press 9 Setting Entry Code Length Default 4 digits Press 0 3 Length Length 1 6 for entry...

Страница 7: ...ondition on the input occurs before access is granted with an entry code or with the request to enter input a FORCED ENTRY output will occur If an open condition remains 60 seconds after a relay activ...

Страница 8: ...vation Press 4 2 Sound Sound 1 for Yes 0 for No Beep Sounds During Output 3 Default No Selects whether or not the keypad beeps during Output 3 activation Press 4 3 Sound Sound 1 for Yes 0 for No Beep...

Страница 9: ...ock the keypad using the keylock see Figure 9 REMOVE JUMPER JP1 TO REDUCE THE SOUND LEVEL OF THE BEEPER Figure 8 Removing Beeper Jumper HOOK KEYPAD ONTO BACKPLATE USE KEY TO LOCK KEYPAD Figure 9 Locki...

Страница 10: ...l turn green and the programmed relay will activate for the programmed time If the number of incorrect codes entered exceeds the keypad lockout count the yellow LED will light indicating that the keyp...

Страница 11: ...ANAGER S ENTRY CODE LOG NAME ADDRESS OR APARTMENT NUMBER ENTRY CODE RELAY NUMBER 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2...

Страница 12: ...t Linear Technical Services at 1 800 421 1587 for an RPA and other important details FCC NOTICE Changes or modifications not expressly described in this manual or approved by the manufacturer could vo...

Отзывы: