Copyright © 2014 Linear LLC.
1
2GIG-TAKE-KIT1
HARDWIRE CONVERSION KIT
INSTALL INSTRUCTIONS
The
2GIG
Hardwire
Conversion
Kit
(2GIG
‐
TAKE
‐
KIT1)
provides
installers
with
an
easy
method
for
taking
over
a
pre
‐
wired
security
alarm
system
and
converting
the
existing
hardwired
zones
to
wireless
zones.
To
ensure
optimal
performance
with
the
2GIG
Control
Panel,
the
kit
provides
an
ABS
Plastic
enclosure
(UL
94:
V
‐
0)
to
protect
the
kit’s
components.
The
enclosure
houses
up
to
three
(3)
Super
Switch
Takeover
Modules
(2GIG
‐
TAKE
‐
345)
and
the
Power
Supply
Board
with
backup
battery
charging
circuit.
It
also
includes
a
space
for
placing
a
suitable
backup
battery.
The
kit
includes
one
(1)
Super
Switch
Takeover
Module
(
Wireless
Takeover
of
an
Alarm
System.
US
Patent
No.
8,638,218
).
You
can
also
install
two
(2)
additional
modules,
which
permits
you
to
convert
up
to
24
pre
‐
wired
security
zones
to
wireless
zones
(each
module
converts
eight
(8)
zones).
IMPORTANT:
The
Super
Switch
cannot
be
used
to
monitor
Carbon
Monoxide
(CO)
or
Fire
detection
zones
and
the
Hardwire
Conversion
Kit
is
intended
for
indoor
use
only.
Figure 1
Hardwire Conversion Kit
Box Contents
Verify
that
the
package
includes:
•
1—Super
Switch
Takeover
Module
(2GIG
‐
TAKE
‐
345)
•
1—Plastic
Bracket
•
2—Phillips
Head
Screws
for
Plastic
Bracket
•
1—12/24
VDC
Power
Supply
Board
•
1—16.5VAC
50
VA
Grounded
Plug
‐
in
Transformer
•
1—ABS
Plastic
Wall
‐
Mount
Enclosure
•
1—Removable
Enclosure
Door
•
4—Drywall
Anchors
and
Phillips
Head
Screws
for
mounting
the
enclosure.
•
1—Double
‐
sided
Adhesive
Tape
for
Super
Switch
Plastic
Bracket
•
3—2.5
inch
(6.35
cm)
Double
‐
Stick
Foam
Strips
for
Power
Supply
Board
•
1—2.5
inch
(6.35
cm)
Double
‐
Stick
Foam
Strips
for
Plug
‐
in
Transformer
Additional Equipment
Additional
equipment
can
be
purchased
to
enhance
the
Hardwire
Conversion
Kit:
•
Backup
Battery
(Required)
.
You
must
install
a
12
V,
1.4
AH
Rechargeable
Sealed
Lead
Acid
Battery
(or
better).
•
Linear
H208
(Optional)
.
This
kit
is
recommended
for
locking
the
plastic
wall
‐
mount
enclosure
with
a
key
for
additional
security.
For
details,
visit:
product_detail.php?productId=317
Mounting the Enclosure to the Wall
When
completing
the
steps
below,
refer
to
To
mount
the
enclosure
to
the
wall:
1
Choose
a
location
within
RF
range
of
the
Control
Panel.
Before
you
begin,
ensure
the
mounting
location
is
free
of
electrical
wires
and
plumbing
systems
before
drilling
into
the
wall.
2
Temporarily
remove
the
enclosure
door
by
lifting
the
cover
up
and
pushing
it
back
until
the
door’s
hinge
pins
disengage.
3
Using
the
four
(4)
keyhole
slots
as
a
template,
mark
the
location
of
the
four
(4)
mounting
holes
at
the
top
of
the
keyhole
slots.
Ensure
that
the
enclosure
will
be
level.
4
Remove
the
enclosure
from
the
wall
and
drill
3/16”
starter
holes
for
the
screws
at
the
four
(4)
marked
locations.
5
Push
each
of
the
wall
anchors
into
the
drilled
holes,
ensuring
the
wall
anchor
heads
are
flush
with
the
wall.
6
Screw
two
(2)
of
the
Phillips
head
screws
into
the
bottom
wall
anchors,
leaving
the
heads
exposed.
Do
not
screw
these
in
all
the
way.
7
Pull
the
cord
for
the
Grounded
Plug
‐
in
Transformer
through
one
of
the
access
holes
or
knockout
in
the
back
of
the
enclosure.
8
Pull
the
wires
for
all
of
the
wired
sensors
through
the
enclosure’s
access
holes
and/or
knockout
as
needed
.
9
With
the
enclosure
in
place,
insert
the
two
(2)
screw
heads
into
the
top
wall
anchors.
Ensure
the
screw
heads
are
at
the
upper
end
of
the
keyhole
slots.
Then
tighten
both
screws.
10
Lift
the
enclosure
and
insert
the
screw
heads
into
the
lower
keyhole
slots.
11
Slide
the
enclosure
downwards
so
the
screw
heads
are
at
the
upper
end
of
the
keyhole
slots.
12
Ensure
that
the
enclosure
is
level.
13
Tighten
the
screws.
14
Continue
with