LTC4000
4
4000fb
For more information
elecTrical characTerisTics
The
l
denotes the specifications which apply over the full operating
junction temperature range, otherwise specifications are at T
A
= 25°C. V
IN
= V
CLN
= 3V to 60V unless otherwise noted (Notes 2, 3).
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Charge Termination
CX Pin Pull-Up Current
V
CX
= 0.1V
l
–5.5
–5.0
–4.5
µA
V
CX,IBMON(OS)
CX Comparator Offset Voltage, IBMON Falling
V
CX
= 0.1V
l
0.5
10
25
mV
V
CX,IBMON(HYS)
CX Comparator Hysteresis Voltage
5
mV
TMR Pull-Up Current
V
TMR
= 0V
–5.0
μA
TMR Pull-Down Current
V
TMR
= 2V
5.0
μA
TMR Pin Frequency
C
TMR
= 0.01μF
400
500
600
Hz
TMR Threshold for CX Termination
l
2.1
2.5
V
t
T
Charge Termination Time
C
TMR
= 0.1μF
l
2.3
2.9
3.5
h
t
T
/t
BB
Ratio of Charge Terminate Time to Bad Battery
Indicator Time
C
TMR
= 0.1μF
l
3.95
4
4.05
h/h
V
NTC(COLD)
NTC Cold Threshold
V
NTC
Rising, % of V
BIAS
l
73
75
77
%
V
NTC(HOT)
NTC Hot Threshold
V
NTC
Falling, % of V
BIAS
l
33
35
37
%
V
NTC(HYS)
NTC Thresholds Hysteresis
% of V
BIAS
5
%
V
NTC(OPEN)
NTC Open Circuit Voltage
% of V
BIAS
l
45
50
55
%
R
NTC(OPEN)
NTC Open Circuit Input Resistance
300
kΩ
Voltage Monitoring and Open Drain Status Pins
V
VM(TH)
VM Input Falling Threshold
l
1.176
1.193
1.204
V
V
VM(HYS)
VM Input Hysteresis
40
mV
VM Input Current
V
VM
= 1.2V
±0.1
µA
I
RST
,
CHRG
,
FLT
(LKG)
Open Drain Status Pins Leakage Current
V
PIN
= 60V
±1
µA
V
RST
,
CHRG
,
FLT
(VOL)
Open Drain Status Pins Voltage Output Low
I
PIN
= 1mA
l
0.4
V
Input PowerPath Control
Input PowerPath Forward Regulation Voltage
V
IID,CSP
, 3V ≤ V
CSP
≤ 60V
l
0.1
8
20
mV
Input PowerPath Fast Reverse Turn-Off
Threshold Voltage
V
IID,CSP
, 3V ≤ V
CSP
≤ 60V,
V
IGATE
= V
CSP
– 2.5V,
∆I
IGATE
/∆ V
IID,CSP
≥ 100μA/mV
l
–90
–50
–20
mV
Input PowerPath Fast Forward Turn-On
Threshold Voltage
V
IID,CSP
, 3V ≤ V
CSP
≤ 60V,
V
IGATE
= V
IID
– 1.5V,
∆I
IGATE
/∆ V
IID,CSP
≥ 100μA/mV
l
40
80
130
mV
Input Gate Turn-Off Current
V
IID
= V
CSP
, V
IGATE
= V
CSP
– 1.5V
–0.3
μA
Input Gate Turn-On Current
V
CSP
= V
IID
– 20mV,
V
IGATE
= V
IID
– 1.5V
0.3
μA
I
IGATE(FASTOFF)
Input Gate Fast Turn-Off Current
V
CSP
= V
IID
+ 0.1V,
V
IGATE
= V
CSP
– 3V
–0.5
mA
I
IGATE(FASTON)
Input Gate Fast Turn-On Current
V
CSP
= V
IID
– 0.2V,
V
IGATE
= V
IID
– 1.5V
0.7
mA
V
IGATE(ON)
Input Gate Clamp Voltage
I
IGATE
= 2µA, V
IID
= 12V to 60V,
V
CSP
= V
IID
– 0.5V, Measure
V
IID
– V
IGATE
l
13
15
V
Input Gate Off Voltage
I
IGATE
= – 2μA, V
IID
= 3V to 59.9V,
V
CSP
= V
IID
+ 0.5V, Measure
V
CSP
– V
IGATE
l
0.45
0.7
V