background image

2

dc1855af

DEMO MANUAL DC1855A

Quick start proceDure

It  is  easy  to  set  up  demonstration  circuit  DC1855A  to 

evaluate the performance of the LT3030. Refer to Figure 1  

for the proper measurement equipment setup and follow 

the procedure below:  
1. With the input supplies and loads off and turned down, 

make all connections according to Figure 1. Set the 

output voltages for channels 1 and 2 with the VOUT 

SELECT jumpers. Make sure the VOUTEN jumpers are 

in the ON positions.

2. Turn on the input supplies and increase them to the 

desired input voltages.

NOTE WHEN SETTING THE INPUT VOLTAGE:  An input 

voltage that is too close to the programmed output volt-

age (too low) may cause dropout operation and a loss 

of output voltage regulation. An input voltage that is too 

high above the output may increase power dissipation to 

an unacceptable level. Finally, a protection feature within 

the LT3030 reduces output current capability at higher 

input voltages.
3. Increase the loads to the desire output current. Verify 

that  the  output  voltages  are  as  programmed  by  the 

VOUT SELECT jumpers.

NOTE: If an output voltage is low, temporarily disconnect 

the load to make sure that it is not set too high.
4. Once the proper output voltages are established, adjust 

the input voltage and load within the operating ranges 

and observe the output voltage regulation, low quiescent 

current, shutdown and PWRGD operation and other 

parameters.