background image

2

dc1836af

DEMO MANUAL DC1836A

harDware setup

JumPEr SETTingS
Tmr PEriOD
: Sets the amount of time the user has to 

hold down the pushbutton in order to cause a shutdown 

event. It can either be set to 32ms or 3 seconds.
On FunCTiOn: Connect to ON BLOCKED to block the ON 

pin falling edge from activating system turn-off. Connect 

to ON ACTIVE to allow both the ON pin rising and falling 

edges to activate system turn-on and turn-off, respectively.
Vin/On: Connects or disconnects VIN from ON. Unless 

external circuitry has been connected to ON, for ON to 

function correctly, this should be set to ON. 
KiLL: Ties or separates 

INT

 from 

KILL

. Set to TIE for au-

tomatic shutdown when a long press on the pushbutton 

is detected.
LDO_in: Chooses the input to the onboard LT3060 regula-

tor. The user can either set it to VIN to have it connected 

to the VIN pin or EXTERNAL in order to have it driven by 

the LDO_IN turret. See the Operating Principles section. 

Only for LED/monitor circuitry. 

EXTErnAL COnnECTiOnS
Signal connections are made via the row of turret posts 

along the edges of the board. 
gnD: (3 turrets) These turrets are connected directly to 

the ground planes.
Vin: Connect a 1.6V to 36V power supply to this turret. 
On: Can be linked to VIN through the VIN/ON jumper, however,  

can also be externally connected to a power source. Is con- 

nected directly to the ON pin of the LTC2955. If the ON 

function jumper is set to active, this pin can be used to turn 

on the EN pin, or turn off the 

EN

 pin, depending on if the 

demo board is populated with an LTC2955-1 or LTC2955-2. 

PB

: This pin is already driven by the pushbutton, however, 

if needed it can be driven by an external signal to simulate 

a pushbutton press. 
LDO_in: Can be used to provide the LT3060 with power 

when the LDO_IN jumper is set to external. 
LDO_OuT: Output from the LT3060. The state of this can 

also be monitored at D1. 

DigiTAL COnnECTiOnS
En/

EN

: Active high (LTC2955-1), or active low (LTC2955-

2) signal. Should go active either on a valid ON signal or 

with a debounced PB press. 

INT

: Goes low on a pushbutton press when EN/

EN

 is  

active. Can be tied to KILL to turn off the part. 

KILL

: A low signal at this input will disable EN/

EN

. The 

TMR period jumper sets how long the input signal must 

be held low. 
PgD: Power good output from the LTC2955. This pin 

indicates the status of the ON pin in order to let the sys-

tem differentiate between pushbutton turn-on and supply 

button turn-on events. 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Отзывы: