10
c. Soft mode setting
SF.OF : Close soft mode
SF.01 : Slow mode, fade in within 1.2s
SF.02 : Fast mode, fade in within 0.6s
SF.03 : Fade in at 0.6s, fade out at 1.2s
S O F T
S F 0 F
S F 0 1
S F 0 2
S F 0 3
d. White balance fine adjustment instruction
R 2 5 5
G 2 5 5
b 2 5 5
W 2 5 5
S A V E
UP
And
DOWN
Power ON
X 2 5 5
X 0 0 0
Save & exit
4. TROUBLESHOOTING LIST
Phenomenon
Solution
The fixture does not work
No light out
No display
Check main power fuse & power cable connection
Measure main voltage on the main connector
Check connection of display PCB
Replace a new display
No responding to DMX controller Check a working mode setting on display is DMX mode
or not
Check whether the unit be set as slave
Check DMX address settings
Check DMX cable and it’s connection
Try to use another DMX console
Signal error while use DMX
Check whether DMX cables be connected well or not
Check whether the DMX cable has terminated with a
terminator to reduce signal errors. If not, please solder
a 120 ohm 1/4W resistor between pin 2 (DMX -) and pin
3 (DMX +) into a DMX output of the last fixture