3.5.14 GPO (1-4) Alert When
Configures each of the four general purpose outputs
?
Never: GPO inactive
?
Follow GPI: Each GPO will match the state of the corresponding GPI, so that if
GPI 1 is commanded Low, GPO 1 will follow.
?
LKFS Over Thr: GPO will be active if the currently monitored input audio
exceeds the adjustable threshold (described below).
?
LKFS Under Thr: GPO will be active if the currently monitored input audio falls
below the adjustable threshold (described below).
?
Silence Detect: GPO will be active if silence (no audio) is detected at the
currently selected input.
?
Reference Loss: GPO will be active if a loss of the currently selected sync
reference is detected.
3.5.15 GPO Threshold (1-4)
Adjustable from Mute to 0db, with -40dB as the default by turning the menu knob.
3.5.16 GPO On Delay (1-4)
Adjusts how long the unit will wait before triggering the GPO. Settings between 0 and 20
seconds are selectable by turning the menu knob. The default setting is 0 seconds.
3.5.17 GPO Off Delay (1-4)
Adjusts how long to hold a GPO function once triggered.
3.6 Communication Menu
Displays and, where applicable, adjusts the IP address, subnet mask, and MAC
address. Changes can be made to the highlighted values by turning the menu knob. To
move back and forth between settable value fields, move the menu knob left or right. An
asterisk (*) indicates changes have been made to the particular parameter. To apply the
changes, move the menu knob to the right one step past the final field.
When changes
are applied, the front panel logo backlight will turn red, the unit will immediately reboot,
and there will be an interruption to program audio.
3.6.1 IP Address
Allows you to assign an IP address to the AERO.lite.
3.6.2 Net Mask
Allows you to configure the subnet mask.