background image

USER AND MAINTENANCE MANUAL 

 

User manual version 11/2009 

                                                                                                                                                                              
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

User and maintenance manual 

 

 

 

 

 

 

 

 

 

 

                             HOT-AIR PELLET INSERT 

 

 

             

18545       

 

 

 

Содержание 18545

Страница 1: ...USER AND MAINTENANCE MANUAL User manual version 11 2009 1 User and maintenance manual HOT AIR PELLET INSERT 18545...

Страница 2: ...NEA VZ SRL declines all liability both civil and criminal for any accidents resulting from partial or total failure to observe the instructions contained herein LINEA VZ SRL moreover declines all liab...

Страница 3: ...45 p 5 Installation positioning the stove p 6 Connection to the power supply p 6 Connections chimney flue gas exhaust air intake p 7 9 Fuel to be used p 10 Display and menu p 11 15 Setting the clock p...

Страница 4: ...on the market The same rule applies to furniture chairs curtains etc distance of 100 cm at the front Do not insert the stove in narrow spaces that have not been specially prepared or lean it against...

Страница 5: ...DED Room temperature probe Flue gas temperature probe Weekly timer thermostat Five pellet feed settings Five fan speed settings Warm air supply fan Self cleaning glass Ash drawer Remote control Packag...

Страница 6: ...tove must be connected to the power supply using an earthed socket making sure that the socket is working correctly before plugging the stove in 2 During installation make sure that the connection cab...

Страница 7: ...E INSTALLATION Both Figures 1 and 2 apply For all the solutions illustrated there are two possible alternatives 1 Take in air directly from the outside through a pipe connected to the fitting provided...

Страница 8: ...uratura fumaria esistente Installation without masonry chimney Installation with existing chimney combustion air taken in from the outside combustion air taken in from the outside combustion air taken...

Страница 9: ...5 100 To H 1200 1 5 3 0 120 Fig 4 From H 600 0 5 1 5 100 To H 1200 1 5 3 0 120 Fig 1 From H 1200 0 5 1 5 120 To H 1800 1 5 3 0 140 Fig 2 From H 1200 0 5 1 5 80 To H 1800 1 5 3 0 100 Fig 3 From H 1200...

Страница 10: ...ust and shredded waste wood without using additives dyes or other foreign materials Pellet technical specifications Diameter 6 6 5 mm Maximum length 20 25 mm Maximum moisture content 6 Heat value appr...

Страница 11: ...rol can also be used as a room timer thermostat and installed on the wall using the bracket supplied The meanings of the status indicators on the left side of the display are described in the figure W...

Страница 12: ...and the main functions Display Sensore temperatura ambiente ON OFF Incremento Decremento Accesso al menu SET tipo alimentazione Set Temperatura ambiente Scorri menu Set Potenza Scorri menu Display Roo...

Страница 13: ...he desired item with P1 and P2 and confirm by pressing P3 01 FAN SET menu 02 CLOCK SET menu 03 TIMER SET menu 04 LANGUAGE menu 05 STANDBY menu 06 BUZZER MODE menu 07 INITIAL FEED menu 08 STOVE STATUS...

Страница 14: ...03 02 daily program This is used to enable disable and set the daily timer thermostat functions Two time bands can be programmed defined by times set in the following table where the OFF setting tell...

Страница 15: ...OFF in the time field the clock ignores the corresponding setting Warning set the programs with care in general avoid setting overlapping switch on off times on the same day in different programs PRO...

Страница 16: ...if wanting to use the weekly program Always keep the weekend program disabled if using the weekly programs 1 2 3 and 4 Enable weekend programming only after disabling weekly programming Menu 04 set la...

Страница 17: ...or a time of 110 seconds when the the stove is off and cold Start by pressing P1 and stop by pressing P3 Menu 08 stove status This is used to read the feed screw and heat output setting parameters and...

Страница 18: ...press P1 or P2 to increase or decrease by stove heat output and automatically set all of the corresponding parameters The display shows the selected heat output If the room temperature measured by the...

Страница 19: ...is switched on manually by pressing and holding P3 ON OFF for a few seconds The same button is used to switch the stove off A complete cycle usually comprises five distinct phases ignition flame stab...

Страница 20: ...nd the room temperature measured T room room temperature measured by the probe T setRoom room temperature set on the external thermostat T setTherm room temperature set for the SET ROOM TEMP parameter...

Страница 21: ...rks at the set speed and the display will show the message FINAL CLEANING When the flue gas temperature returns to the minimum operating threshold the heat exchanger fan is also switched off and after...

Страница 22: ...y thermostat SAFE FAIL ALARM Faulty flue gas fan FAN FAIL ALARM All alarm conditions cause the stove to shut down immediately Alarm status commences after the time set for Pr11 in seconds and can be r...

Страница 23: ...re higher than the activation threshold it switches off the feed screw powered in series and simultaneously via terminal AL1 on CN4 sends the controller the signal to change status The message SAFE FA...

Страница 24: ...cloth moistened with water Never use degreasing substances alcohol thinners acetone or petrol as these would irreparably damage the paint Cleaning the glass The ceramic glass on the firebox door is r...

Страница 25: ...ash accumulated inside the furnace compartment The frequency of cleaning the burn pot will depend on the type of pellets used Always check the flame if it turns red is weak or releases black smoke th...

Страница 26: ...service centre Replace the glow plug unplug the power cable before proceeding Check that there are no pellets stuck in the chute Check that the feed screw is not blocked Check the door seal Stove shu...

Страница 27: ...nd from the outside Insufficient combustion air in the furnace Flue gas pipes blocked The type of pellets used has been changed Adjust combustion air flow Check the quantity of pellets Gradually decre...

Страница 28: ...ondary heat exchanger no 2 Feed screw Main heat exchanger Glow plug Flue gas tempera ture probe Room temperature probe Supplementary thermostat ALF General safety thermostat ALC Draught pressure switc...

Страница 29: ...of example the gaskets the burn pot the firebox lining the ceramic glass the painted parts and the ceramic etc The warranty is valid for 24 months from the first ignition date marked on this certific...

Страница 30: ...recommended to always contact the dealer who sold the appliance or our nearest service centre specifying the appliance model serial number and the type of problem Also remember that original spare par...

Страница 31: ...NO YES NO YES NO User s signature Service centre signature SPECIALIST SERVICE CENTRE SERVICE PERFORMED ON Materials used Warranty YES NO YES NO YES NO YES NO User s signature Service centre signature...

Страница 32: ...aletecnicospecializzato Si declinaogni responsabilit incasodi danni apersoneeacosederivanti LINEA VZ Srl Headquarters Via Abbate Tommaso 90 30020 Z I Quarto D Altino Venice ITALY tel 39 0422 780750 fa...