CE/FCC Statement 

 

 

 

CE Certification 

This equipment complies with the requirements relating to Electromagnetic Compatibility Standards.  
It has been manufactured under the scope of RoHS compliance. 
 

 
CE Konformitätserklärung 

Dieses  Produkt  entspricht  den  einschlägigen  EMV  Richtlinien  der  EU  für  IT-Equipment  und  darf  nur 
zusammen mit abgeschirmten Kabeln verwendet werden. 
Diese Geräte wurden unter Berücksichtigung der RoHS Vorgaben hergestellt. 
Die formelle Konformitätserklärung können wir Ihnen auf Anforderung zur Verfügung stellen 
 
 

FCC Certification 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference  when  the  equipment  is  operated  in a  commercial  environment.  This  equipment  generates, 
uses,  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the 
instruction manual, may cause harmful interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which case the user will be required to correct 
the interference at his own expense.  

You  are  cautioned  that  changes  or  modification  not  expressly  approved  by  the  party  responsible  for 
compliance could void your authority to operate the equipment. 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

1. This device may not cause harmful interference, and 

2. This device must accept any interference received, including interference that may cause undesired 

operation. 

 

 

LINDY Herstellergarantie 

– Hinweis für Kunden in Deutschland 

LINDY gewährt für dieses Produkt über die gesetzliche Regelung in Deutschland hinaus eine zweijährige Hersteller-
garantie ab Kaufdatum. Die detaillierten Bedingungen dieser Garantie finden Sie auf der LINDY Website aufgelistet 
bei den AGBs.   

 

Hersteller / Manufacturer (EU):

Manufacturer (UK):

 

LINDY-Elektronik GmbH 

LINDY Electronics Ltd 

Markircher Str. 20 

Sadler Forster Way 

68229 Mannheim 

Stockton-on-Tees, TS17 9JY 

Germany 

England 

Email: [email protected] , T: +49 (0)621 470050 

[email protected] , T: +44 (0)1642 754000 

 

 

Содержание 32657

Страница 1: ...ber 2020 IPower Switch Classic 8 IPower Switch Classic 16 User Manual English Benutzerhandbuch Deutsch Manuel Utilisateur Fran ais Manuale Italiano No 32657 32658 lindy com Tested to comply with FCC s...

Страница 2: ......

Страница 3: ...tion of the power strip Power consumption charts for daily monthly or a user defined period Build in true RMS current meter Easy setup the display shows the current IP address of the unit directly LED...

Страница 4: ...ere is no DHCP server present the IP address will be set to 192 168 0 216 Software Installation To manage a group of outlets we recommend downloading the software from the Lindy website Single outlets...

Страница 5: ...g the button and releasing it after to beeps will show up the unit s IP address c Pressing the button and releasing it after 4 beeps changes the IP address mode from fixed to DHCP and vice versa d Pre...

Страница 6: ...e warning and overload value setting Information System This tab provides all necessary information regarding system and SNMP Control Outlet This tab provides an overview of the outlet status Select t...

Страница 7: ...gle outlet or group outlets Configuration Threshold This tab is to configurate thresholds Configuration User Change the ID and password The default ID is snmp and the default password is 1234 The user...

Страница 8: ...rk If there is no DHCP server present the IP address will be set to 192 168 0 216 Configuration Mail This tab is to configure messages to pre defined accounts when different evens are occurring The me...

Страница 9: ...6 Firefox and Google Chrome are not supported Software Please start the software always via Right Click Run as administrator When using the software for the first time the database type must be selec...

Страница 10: ...nitored PDUs Device Add device The system administrator can add a PDU manually if the IP address of the PDU has been setup before Device Group Select the PDUs which belong to a group Community Set the...

Страница 11: ...ation for the PDU Network Settings Re define the IP address of the PDU Total Current Threshold Settings This function is only available when there is more than one PDU available under this IP address...

Страница 12: ...y Add device group Create a new group Edit Group Rename the group Remove device group Delete an existing group All PDUs listed under this group must be removed first Data Management Export kW hr Accou...

Страница 13: ...et or scan the specific subnet 2 Press the Scan button to search for all PDU devices under this subnet 3 Check the box of Add for those you want to add to PDU utility 4 Select one of the groups in the...

Страница 14: ...or can add delete and manage all user privilege in this tab User can only change the password for the admin account Add Edit user User can be assigned to the authority of Read only or Read Write The p...

Страница 15: ...g In this tab the database settings can be modified Service Control Please note If the service cannot start it could be that the SNMP port had been used by another program of Windows OS Please close t...

Страница 16: ...the PDU exceeds the threshold of warning o Overload The power consumption of the PDU exceeds the threshold of overload Update Time Indicates when the PDU information has been updated the last time De...

Страница 17: ...ication status with PDU utility o Normal The PDU utility communicates with the PDU normally o Querying The PDU utility is requesting data from the PDU o Communication Lost The PDU utility cannot get d...

Страница 18: ...rts outlet control you can click on the hyperlink and enter to the PDU web page to control the outlet The Power Consumption Chart provides the chart for the PDU power consumption record The administra...

Страница 19: ...User Manual English Events This tab provides events log Report This tab provides data analysis 1 Accumulated Power 2 Average Current 3 Average Temperature 4 Average Humidity...

Страница 20: ...ference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own...

Страница 21: ...bernehmen die Ger tehersteller LINDY bietet deutschen Endverbrauchern ein kostenloses R cknahmesystem an beachten Sie bitte dass Batterien und Akkus den Produkten vor der R ckgabe an das R cknahmesys...

Отзывы: