background image

 

Page 26 

Installation and Use 

LINDY CPU Switch USB

 

 

3.9 Querying the LINDY CPU Switch USB’s firmware version 

 

For technical support reasons it may sometimes be desirable to know the firmware 

version of your LINDY CPU Switch USB. If the front panel key is held down whilst 

the LINDY CPU Switch USB is powered on then the firmware version will be 

displayed as a sequence of numbers and characters. The three digits of the 

firmware version are shown in sequence on the 7-segment display, one at a time, 

alternating with the letter F. When the firmware version has been displayed the 

LINDY CPU Switch USB will display and equals sign and resume normal operation. 

For example the following sequence would indicate firmware version 1.23. 

 

))) 

 

3.10 PC and Macintosh keyboard equivalent key mappings 

 

If you are connecting a mixture of IBM compatible PCs and Macintosh computers to 

the LINDY CPU Switch USB then you have several possible keyboard configuration 

options. You may decide to connect both a Macintosh and PC style keyboard to the 

LINDY CPU Switch USB and use the appropriate keyboard for the appropriate 

system. Alternatively you may wish to use the same keyboard to control both 

systems. In this case we recommend that you use a PC 104/105-key keyboard. This 

has more keys than the Macintosh keyboard and so is more suited to universal use. 

 

The equivalent key mappings on the IBM PC 104/105 –key keyboard and the Apple 

keyboard are shown in the following table: 

 

  IBM 

104/105-key 

  Apple 

keyboard 

 

 

keyboard 

 

 

 

 

  Left 

Ctrl 

   Left 

Control 

 

 

Left Win Start (

  Left 

Command 

( )  

  Left 

Alt    Left 

Option 

(alt) 

 

 

 

Right Alt or Alt Graph 

 

Right Option (alt) 

 

 

Right Win Start (

  Right 

Command 

( )  

  Right 

Ctrl 

   Right 

Control 

  Windows 

Application 

(

)  

No equivalent 

  No 

equivalent    On 

off 

key 

 

 
 
 

Содержание 32 341 and use

Страница 1: ...witch USB Installation and Use First edition January 2000 2000 LINDY Electronics Ltd LINDY CPU Switch USB Installation and Use Part Model 32 341 LINDY CPU Switch USB PC Part Model 32 342 LINDY CPU Swi...

Страница 2: ...oor environments only w Warning live parts contained within power adapter w No user serviceable parts within power adapter do not dismantle w Plug the power adapter into a socket outlet close to the L...

Страница 3: ...the terms of this warranty shall in all circumstances be limited to the replacement value of this product If any difficulty is experienced in the installation or use of this product that you are unab...

Страница 4: ......

Страница 5: ...he receiver is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency ener...

Страница 6: ...witch USB 11 2 3 Connecting your devices 11 2 4 Configuring the LINDY CPU Switch USB 14 2 4 1 Setting the USB enumeration guard time 15 2 4 2 Setting the autoscan dwell time 15 2 4 3 Setting the LINDY...

Страница 7: ...3 5 Keyboard hotkey control 20 3 6 Mouse control 22 3 7 Autoscan mode 22 3 8 The optional remote controller 22 3 9 Querying the LINDY CPU Switch USB s firmware version 23 3 10 PC and Macintosh keyboa...

Страница 8: ...quality video resolutions up to 1600 x 1280 pixels and screen refresh rates up to 100 Hz Each computer may be connected using just one standard USB cable and one standard video cable Robust metal cha...

Страница 9: ...traditional style PC keyboard and mouse to be connected to the LINDY CPU Switch USB LINDY CPU Switch USB s channel can be changed using keyboard hotkeys or a 3 button mouse Traditional style PS 2 key...

Страница 10: ...Page 10 Installation and Use LINDY CPU Switch USB 1 4 Product information Fig 1 LINDY CPU Switch USB model 32 341...

Страница 11: ...LINDY CPU Switch USB Installation and Use Page 11 Fig 2 Remote control pad display optional accessory Part 32 255 Fig 3 LINDY CPU Switch USB model 32 342...

Страница 12: ...vers for all the USB peripherals that you wish to connect to the LINDY CPU Switch USB Common drivers such as those for keyboards and mice are usually included with the operating system If you are conn...

Страница 13: ...t these devices connected If you wish to use the PS 2 style mouse to switch the LINDY CPU Switch USB s channel then you will need a three button mouse or a LINDY mouse 2 2 Mounting the LINDY CPU Switc...

Страница 14: ...onitor connections Lower quality data cables will function correctly but will generally give relatively poor video pictures and are only suitable for screen resolutions of 640 x 480 Any unused compute...

Страница 15: ...LINDY CPU Switch USB Installation and Use Page 15 Figure 4 a typical LINDY CPU Switch USB installation whereby a range of peripherals are shared between four computers...

Страница 16: ...follows Reserved set OFF ON OFF 1 2 3 4 5 6 7 8 Scan all ports Scan active ports only default Autoscan dwell time 5 seconds Autoscan dwell time 2 seconds default Enumeration guard time 16 seconds Enab...

Страница 17: ...ch USB has locked on to a channel it will remain connected to that channel for at least the enumeration guard time This ensures that the enumeration process is complete before further channel changes...

Страница 18: ...USB interface cable The LINDY CPU Switch USB is not able to detect an active computer if a USB cable from that computer is not connected to the LINDY CPU Switch USB 2 4 4 Setting the keyboard hotkey...

Страница 19: ...keyboard or mouse until a suitable driver has been loaded It may only be possible to load these drivers if you have keyboard and mouse control and so consequently you may need to connect a traditional...

Страница 20: ...Page 20 Installation and Use LINDY CPU Switch USB has been disconnected and triggers the automatic recovery system Plug in the LINDY PS 2 mouse and the LINDY CPU Switch USB will re initialise it...

Страница 21: ...pressing the front panel key will either select the next active computer channel or the next computer channel in numerical sequence 1 2 3 4 1 2 3 etc Using the front panel key you may cycle through th...

Страница 22: ...ou should avoid switching computers whilst a computer is reading or writing data to a USB data storage device such as a ZIP drive Where practical it is advisable to eject removable disks on USB drives...

Страница 23: ...mbinations on the keyboard attached to the PS 2 style keyboard port see figure 4 All of the hotkey control commands are invoked by holding down the two hotkeys and then pressing a command key By defau...

Страница 24: ...The next channel may be the next active channel or the next channel in numerical sequence depending upon the position of option switch 8 see section 2 4 3 HOTKEYs and A selects autoscan mode where eac...

Страница 25: ...on of option switch 8 the LINDY CPU Switch USB will lock on to all the computer ports or just the active computer ports Many modern monitors are fitted with automatic power save relays and will switch...

Страница 26: ...valent key mappings If you are connecting a mixture of IBM compatible PCs and Macintosh computers to the LINDY CPU Switch USB then you have several possible keyboard configuration options You may deci...

Страница 27: ...Video cables You will require a video cable for each computer that you wish to connect The LINDY CPU Switch USB uses standard video cables that are terminated at each end with a standard 15 way high...

Страница 28: ...on cables Extension cables should be terminated with 6 pin mini DIN PS 2 style connectors with a male connector on one end and a female connector on the other end All pins on the extension cable shoul...

Страница 29: ...g between computers during the enumeration process Problem Video is fuzzy or smudged Action Ensure that you are using high quality tri coax video cables These can be easily identified as they are roug...

Отзывы: