2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]
8
|
P a g e
LB-1000-RR
User Manual
5.0 LB-1000-RR SETTINGS
Once the LB-1000-RR module is successfully connected, powered up and operating normally,
you will be able to see the corresponding slot populated with the module on the screen and on
the web interface of the LB-1000-CM system management module.
5.1
LB-1000-RR settings: Using touch screen
On the home screen of the LB-1000-CM touch screen, tap/touch the corresponding application
module slot (01-18) where the LB-1000-RR is plugged in. The selected application module will be
highlighted and the screen will show settings for the LB-1000-RR return receiver.
Figure 4: LB-1000-RR settings - Page 1
If a parameter indicates an alarm it will be displayed in
red font
. No alarm, the parameter will be
displayed in
green font
.
PARAMETERS
DESCRIPTION
LB-1000-RR
A / B / C / D Optical Power
Displays the Input Optical power for each of the channels
RF Output ON / OFF
Turn the unused RF Output channel ON/OFF
RF ATT
RF Output control using electronic attenuation. Min value under AGC: 0dB;
Max value under AGC: 31dB; Min value under MGC: 0dB; Max value under
MGC: 62dB