Operation
Crankcase oil service interval
• Check oil level after every 750 hours of
machine operation, or monthly.
• Change oil after every 2 000 hours of
machine operation, or every year.
• Use SAE 10W30 motor oil in all units used
in an ambient temperature of
–40 to 150 °F
(–40 to 65 °C)
.
For ambient temperatures of
–70 to 50 °F
(–56 to 10 °C)
, use Mobil
Aero HFA low temperature oil.
• Oil level should be at indicating dot on
dipstick (middle of crankshaft).
• Use 10W30 motor oil 15 oz
(0,44 l)
.
Prime pump
1
Remove pump outlet line from
outlet port (
55
).
2
With pump in full container of
lubricant, energize pump.
3
Purge air from pump.
4
Verify lubricant is flowing evenly
from pump.
5
Stop pump.
6
Attach pump outlet line to outlet
port (
55
).
Set pump speed
1
Refer to
Fig. 5
and remove speed
adjustment hex socket head (3 mm)
cover screw.
2
Adjust screw counter-clockwise to reduce
pump speed.
3
Install speed adjustment hex socket head
(3 mm) cover screw.
DANGER
Do not exceed maximum rated outlet
pressure. Pumps are not equipped with high
pressure shut off valve.
Failure to comply will result in death or
serious personal injury.
NOTE
Never allow pump to run dry of lubricant.
Dry pump quickly speeds up, creating
friction heat that can damage seals.
Monitor supply lubricant level and refill
when necessary.
Failure to comply may result in damage to
equipment.
NOTE
Motor used in 24 V
FlowMaster II pump
is equipped with a built in speed control.
Pump speed is factory set to maximum
setting, but easily changed in field.
Speed adjustment screw is located
under cover screw, 120° away from
power cord.
NOTE
Do not reduce pump speed below 20 r/min.
Speed adjustment screw has no stop and has
total of 30 turns.
Refer to
Table 2
,
page 3,
for speed
recommendations.
NOTE
Do not change pump settings until after start
up procedure. All pumps are set to run at full
speed.
Failure to comply may result in damage
to pump.
WARNING
Always install relief valve in pump outlet to
ensure pump pressure remains below
5 000 psi
(345 bar)
. Use only high pressure
components.
Failure to comply may result in serious
personal injury.
Fig. 5