Appropriate use
• The air gun was exclusively designed to
pump and dispense lubricant using
pneumatic power
• The maximum specification rating should
not be exceeded
• Any other use not in accordance with
instruction will result in loss of claim for
warranty or liability
Work area
Keep bystanders, children, and visitors away
while operating Distractions can cause you
to make mistakes
Inspection
Visually inspect for damaged, loose or
missing parts If equipment is worn or
damaged, remove from service Contact an
authorized service center for damage
assessment or repair
Operation
Prime the air grease gun after each refill or
grease cartridge change Prime the gun
before using it to lubricate grease points
For optimum performance and product
life, add a few drops of lubricating oil
(SAE 30 or greater) through the air fitting at
the bottom of the handle if gun begins to
cycle slowly or erratically
To prime, operate the gun slowly, by gently
throttling the trigger (
8
), until grease flows
from the open end of the hose The vent/
filler valve (
18
) should be used to expel air
pockets This is done by loosening the vent/
filler valve a couple of turns, holding the gun
with the discharge hose pointing up, and
allowing the air to escape Close the vent/
filler valve after air is removed If a prime can
not be achieved after the gun has operated
for 10-15 seconds, refer to the section
To expel air pockets
,
page 6
The gun will stall if a bearing or fitting is
blocked, causing the grease pressure to rise
to maximum A blocked bearing or fitting
should be corrected before continuing
lubrication
Removing empty
grease cartridge
1
Pull back on the follower handle until the
follower rod is fully extended and latch the
follower rod groove into the slot on the
tube cap
2
Unscrew the grease tube assembly from
the gun
3
Carefully release the follower handle to the
eject the empty cartridge from container
tube
Installation grease
cartridge
1
Pull back on the follower handle and latch
the follower rod groove into the slot on the
tube cap
2
Remove the plastic cap from the grease
cartridge and insert cartridge into
container tube
3
Remove the pull tab from the grease
cartridge and screw grease tube assembly
into pump assembly
4
Release follower rod from slot Purge air
from pump See air purging instruction
Specifications
Pump ratio (max)
40:1
Output per stroke
0 038 in
3
(0,62 cm
3
)
Pneumatic inlet pressure (minimum)
40 psi
(2,7 bar)
Pneumatic inlet pressure (maximum)
150 psi
(10,3 bar)
Grease output pressure (maximum)
6,000 psi
(414 bar)
Grease reservoir capacity
14 5 oz
(450 cm
3
)
Operating temperature range
0 to 120 °F
(–18 to 50 °C)
Weight (empty)
4 5 lbs
(2,0 kg)
Weight (full)
5 5 lbs
(2,5 kg)
Lubricant
Up to NGLI #2 grease
Pneumatic port inlet
1
/
4
–18 NPSF
Grease port outlet
7
/
16
-28 UNEF
CAUTION
Air pockets in the cartridge lubricant will
cause the gun to lose prime
6