A: Fault: The pump motor does not run

 

Cause: 

Remedy: 

Voltage supply interrupted 

Check the voltage supply to the pump. If necessary, eliminate 
the cause of the fault. 

 

 

Voltage supply to the printed-circuit board is 
interrupted 

Check the line leading from the pump plug to the printed circuit 
board. 

 If the voltage is applied, the left-hand LED is lit. 
 

 

Printed circuit board defective 

Replace the printed circuit board. 

 

 

B: Fault: The pump motor runs continuously for duration of the monitoring time (30 
minutes)

 

Cause: 

Remedy: 

 

 

Proximity Switch defective. 

Disconnect the main line leading to the monitored metering 
device 

 Unscrew the proximity switch and test it by insert a metallic pin 

into the borehole of the detector and hold it there for over 2 
seconds and then remove it. If the pump is not switched off 
afterwards, check the cable connections to the pump. If 
necessary, replace the proximity switch along with the 
connector 

 

 

Cable connection of the proximity switch to 
the pump interrupted 

Check the cable connections to the pump. If necessary, replace 
the proximity switch with the connector. 

 

 

Printed circuit board defective 

Replace the printed circuit board 

 

 

Grease line blocked 

Clear the blockage (See section below on locating blockages) 

 

 

Reservoir Empty 

Refill the reservoir 

 

 

Air in the system 

Purge the air from the system. Note: always pre-fill lines and 
divider valves prior to installation 

 

 

Broken supply line to divider valve with 
Proximity switch 

Repair the supply line  

 

 

 

 

 

 

 

 

 