background image

English 

English

II

12/05

THANKS!

  For having choosen the QUALITY of the Lincoln Electric products.

 

Please Examine Package and Equipment for Damage.  Claims for material damaged in shipment must be notified
immediately to the dealer.

 

For future reference record in the table below your equipment identification information.  Model Name, Code &
Serial Number can be found on the machine rating plate.

Model Name:

………………...…………………………….…………………………………………………………………………………………..

Code & Serial number:

………………….……………………………………………….. …………………………………………………….……………..

Date & Where Purchased:

…………………………………………………………………... ……………………….…………………………………………..

ENGLISH INDEX

Safety .............................................................................................................................................................................. 1
Installation and Operator Instructions .............................................................................................................................. 2
Electromagnetic Compatibility (EMC) .............................................................................................................................. 5
Technical Specifications .................................................................................................................................................. 6
WEEE .............................................................................................................................................................................. 6
Spare Parts...................................................................................................................................................................... 6
Electrical Schematic ........................................................................................................................................................ 6

Содержание INVERTEC PC 105

Страница 1: ...IM2002 01 2011 Rev 3 INVERTEC PC 65 PC 105 OPERATOR S MANUAL ENGLISH LINCOLN ELECTRIC ITALIA S r l Via Fratelli Canepa 8 16010 Serrà Riccò GE Italia www lincolnelectric eu ...

Страница 2: ...C65 INVERTEC PC105 conforms to the following directives 2006 95 CEE 2004 108 CEE and has been designed in compliance with the following standards EN 60529 EN 60974 1 EN 60974 10 2005 Dario Gatti European Engineering Director Machines LINCOLN ELECTRIC ITALIA S r l Via Fratelli Canepa 8 16010 Serra Riccò GE Italia 12 05 ...

Страница 3: ...mediately to the dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Safety 1 Installation and Operator Instructions 2 Electromagnetic Compatibility EMC 5 Technical Specifications 6 WEEE 6 Spare Parts 6 Electrical Schema...

Страница 4: ...ating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It makes mandatory the adoption of Personal Protective Equipments PPE having filter with a protection degree up to a maximum of 15 as required by EN169 Standard WORK...

Страница 5: ... not cover the machine with paper cloth or rags when switched on Dirt and dust that can be drawn into the machine should be kept to a minimum This machine has a protection rating of IP23 Keep it dry when possible and do not place it on wet ground or in puddles Locate the machine away from radio controlled machinery Normal operation may adversely affect the operation of nearby radio controlled mach...

Страница 6: ...C 105 only This switch enables disables the Remote Control Connector I Remote Control Connector PC 105 only Connect here the remote control unit Refer to the picture below for the functions related to each pin of the connector front view 1 INPUT 0 5Vdc Output Current Adjustment 2 OUTPUT 12Vdc 1A max Auxiliary Power supply 3 GROUND 4 INPUT Start power source active connecting to GROUND 5 GROUND 6 C...

Страница 7: ...rn ON One second after the switching ON a click from the starter relay will be heard the unit is now ready to operate Check through the Gas Test B switch that the primary air N is available The working pressure should be set at 5bar Set the desired current value with the Output Current A knob To start the cutting process just press the torch button making sure you are not aiming the torch air blow...

Страница 8: ...the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic compatibility in those locations due to conducted as well as radiated disturbances This equipment does not comply with IEC 61000 3 12 If it is connected to a public low voltage system it is responsibility of the installer or user of the equipment to ensure by con...

Страница 9: ... electrical equipment together with normal waste In observance of European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE and its implementation in accordance with national law electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get in...

Отзывы: