SAFETY MARK:  This equipment is suitable for supplying power for welding operations carried out in 
an environment with increased hazard of electric shock. 

 

EQUIPMENT WEIGHT OVER 30kg:  Move this equipment with care and with the help of another 
person.  Lifting may be dangerous for your physical health. 

 

CYLINDER MAY EXPLODE IF DAMAGED:  Use only compressed gas cylinders containing the 
correct shielding gas for the process used and properly operating regulators designed for the gas and 
pressure used.  Always keep cylinders in an upright position securely chained to a fixed support.  Do 
not move or transport gas cylinders with the protection cap removed.  Do not allow the electrode, 
electrode holder, work clamp or any other electrically live part to touch a gas cylinder.  Gas cylinders 
must be located away from areas where they may be subjected to physical damage or the welding 
process including sparks and heat sources. 

HF 

CAUTION:  The high frequency used for contact-free ignition with TIG (GTAW) welding, can interfere 
with the operation of insufficiently shielded computer equipment, EDP centers and industrial robots, 
even causing complete system breakdown.  TIG (GTAW) welding may interfere with electronic 
telephone networks and with radio and TV reception. 

 

Installation and Operator Instructions 

 
Read this entire section before installation or operation 
of the machine. 
 

Location and Environment 

This machine can operate in harsh environments.  
However, it is important that simple preventative 
measures are followed to assure long life and reliable 
operation: 
 

 

Do not place or operate this machine on a surface 
with an incline greater than 15° from horizontal. 

 

Do not use this machine for pipe thawing. 

 

This machine must be located where there is free 
circulation of clean air without restrictions for air 
movement to and from the air vents.  Do not cover 
the machine with paper, cloth or rags when 
switched on. 

 

Dirt and dust that can be drawn into the machine 
should be kept to a minimum. 

 

This machine has a protection rating of: 

 270SX: 

IP23 

 400SX: 

IP23 

Keep it dry when possible and do not place it on wet 
ground or in puddles. 

 

Locate the machine away from radio controlled 
machinery.  Normal operation may adversely affect 
the operation of nearby radio controlled machinery, 
which may result in injury or equipment damage.  
Read the section on electromagnetic compatibility in 
this manual. 

 

Do not operate in areas with an ambient 
temperature greater than 40°C. 

 

Input Supply Connection 

Check the input voltage, phase, and frequency supplied 
to this machine before turning it on.  The allowable input 
voltage is indicated in the technical specification section 
of this manual and on the rating plate of the machine.  
Be sure that the machine is grounded. 
 
Make sure the power available at the input connection is 
adequate for normal operation of the machine.  The fuse 
rating and cable sizes are both indicated in the technical 
specification section of this manual. 

 

Input Supply From Engine Driven Generators 

The machines are designed to operate on engine driven 
generators as long as the auxiliary can supply adequate 
voltage, frequency and power as indicated in the 
"Technical Specification" section of this manual.  The 
auxiliary supply of the generator must also meet the 
following conditions: 

 

Vac peak voltage: below 670V. 

 

Vac frequency: in the range of 50 and 60Hz. 

 

RMS voltage of the AC waveform: 400Vac ± 15%. 

It is important to check these conditions because many 
engine driven generators produce high voltage spikes.  
Operation of this machine with engine driven generators 
not conforming to these conditions is not recommended 
and may damage the machine. 
 

Output Connections 

A quick disconnect system using Twist-Mate

TM

 cable 

plugs is used for the welding cable connections.  Refer 
to the following sections for more information on 
connecting the machine for operation of stick welding 
(MMA) or TIG welding. 

 

(+) Positive Quick Disconnect:  Positive output 
connector for the welding circuit. 

 

(-) Negative Quick Disconnect:  Negative output 
connector for the welding circuit. 

 

Stick Welding (MMA) 

First determine the proper electrode polarity for the 
electrode to be used.  Consult the electrode data for this 
information.  Then connect the output cables to the 
output terminals of the machine for the selected polarity.  
Shown here is the connection method for DC(+) welding. 
 

 

 

Содержание INVERTEC 270SX

Страница 1: ...IM2025 04 2016 REV03 INVERTEC 270SX 400SX OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu ...

Страница 2: ...ERTEC 270SX INVERTEC 400SX conforms to the following directives 2014 35 EU 2014 30 EU and has been designed in compliance with the following standards EN 60974 1 2012 EN 60974 10 2014 20 04 2016 Piotr Spytek Operations Director Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland 12 05 ...

Страница 3: ...ly to the dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Safety 1 Installation and Operator Instructions 2 Electromagnetic Compatibility EMC 5 Technical Specifications 6 WEEE 6 Spare Parts 6 Electrical Schematic 6 A...

Страница 4: ...MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in...

Страница 5: ...ry when possible and do not place it on wet ground or in puddles Locate the machine away from radio controlled machinery Normal operation may adversely affect the operation of nearby radio controlled machinery which may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Input Su...

Страница 6: ...unction Auto Adaptive Arc Force that increases temporary the output current used to clear intermittent connections between the electrode and the weld puddle that occur during stick welding This is an active control feature that guarantees the best arrangement between the arc stability and spatter presence The feature Auto Adaptive Arc Force has instead of a fixed or manual regulation an automatic ...

Страница 7: ...essing the TIG torch electrode on the work piece in order to create a low current short circuit Then the electrode is lifted from the work piece to start the TIG arc Meter The meter displays the preset welding current before welding and the actual welding current during welding Through the Pushbutton on the Display right side the Display alternatively shown the output Current A or Voltage V The LE...

Страница 8: ...io and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible ...

Страница 9: ...t WEEE and its implementation in accordance with national law electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get information on approved collection systems from our local representative By applying this European Directive you will protect the environment...

Отзывы: