English
English
10
Mode Pushbutton:
This pushbutton changes the welding modes of the
machine:
Stick
(SMAW)
Lift
TIG
(GTAW)
HF
TIG
(GTAW)
Spot TIG
(GTAW)
The Spot TIG feature is selectable only if the “option
10” is previously enabled in the Setup Menu. See
“Setup menu” section for options enabling /
disabling.
Each welding mode is is detailed in the Operating
instruction section.
Trigger Mode Pushbutton:
This pushbutton changes the trigger sequence in TIG
welding mode:
2-step / 4-step with restart This option is not
selectable by the Trigger Pushbutton and, if
enabled, operates with 2 or 4 step mode:
This indicator will turn on if the restart option is
enabled for the current TIG trigger mode. Restart
can be enabled separately for 2-step and 4-step
modes from the Setup Menu. More information
about restart is available in the Operating instruction
section.
2-step
4-step
Bi-Level
Each trigger mode is detailed in the Operating instruction
section.
SEL Pushbutton:
The SELect pusbutton is used to scroll the TIG welding
parameters. At each pressure the relevant led is
switched on and the displays show the current value of
the parameter. If a parameter is disabled for the current
mode of working it will be skipped. The user can then
modify this value turning the Output Current knob. If no
change is made after a timeout (4s), the displays and
LEDs will revert to the default state, where the Output
Current knob sets the output current.
Memory Pushbutton:
This pusbutton allows to store (
M) or recall (M
) TIG
welding programs. 10 memory records (P01 to P10) are
available for the user.
To store or recall a record: Push until the Store (
M) or
Recall (M
) LED is ON according to the desired
operation
Into the follow display
will appear, turning the knob, from P01 to P10, all the
possible programs.
Then keep pushed for 4s
The Memory pushbutton is disabled during welding.
See “List of parameters and Factory stored programs”
section below for a complete list of factory stored
programs.
Pulsing Mode Pushbutton:
In the TIG welding modes, this pusbutton turns the
pulsing function ON. When active, the LED next to the
pusbutton is turned ON. In Stick welding mode, this
command is disabled.
When Pulse is active is possible to set Duty cycle (%),
Frequency (Hz) and Background (%) parameters.
During TIG welding is not possible switch ON or OFF the
Pulse command: if ON, during welding is possible
operates on the values of Duty, Frequency and
Background current.
Output Current Knob:
It is used to set the Output Current used during welding.
This knob is also a multi-purpose command: see the
“Operating Instruction” section for a description of how to
use this command for parameters selection.