Impinger I – 1400 Series Advantage Service Manual - Dom & Int’l 

16 

Flame Sensor 

To check for flame sensor operation, connect a digital 
multimeter (capable of measuring D.C. micro amps) 
between the flame sensor wire and Ignition Control. 
Sensor current from sensor control is 3 micro amps 
minimum. If these readings are not achieved replace 
igniter/sensor assembly. Also check for any type of 
damage to flame sensor wire and connections. 

Flame will not stay on 

Ignition Control 

If there is sufficient flame sensor current, but the 
burner will not remain ignited, check the reset button 
on ignition control. If all above are okay, replace 
ignition control. 

No Pilot 

Pilot Orifice 

If all above are operating properly, but there is no pilot 
flame, check for any obstructions in pilot orifice. 

Flame Sensor 

(There should be a visible pilot flame at this time.) To 
check for flame sensor operation, connect a digital 
multimeter (capable of measuring D.C. micro 
amperes) between the flame sensor wire and  the 
ignition control. NOTE: this is a current measurement 
and the meter must be connected in series. Proper 
current readings should be minimum of 3 micro AMP. 
D.C. If these readings are not achieved, replace 
igniter/sensor assembly. Also check for any type of 
damage to flame sensor wire and connections. 

Power Supply 

If there is sufficient micro-amp current, but the flame 
will not stay lit, check for proper polarity of the input 
power supply. 

Pilot flame, but burner 
will not stay ignited 

Ignition Control 

If there is sufficient flame sensor current, but the 
burner will not remain ignited, check reset button on 
ignition control, if all above are okay, replace ignition 
control. 

Gas Control Relay 

Check for 220 VAC to relay coil. If no voltage is 
present, trace wiring back to ignition control. If voltage 
is present, check to insure contacts are closing. 

Temperature Control 

Check for 120 VAC across L1 and L2 on temperature 
control board. If no voltage is present, retrace wiring 
back to power supply. Turn the temperature 
adjustment knob to the maximum temperature 
position and check for 120 VAC at the load terminal to 
neutral.  If 120 VAC is not present, proceed as 
follows: If 120 VAC is present and unit is not heating, 
see "Solenoid Valve." 

Thermocouple Probe 

Remove thermocouple leads from the temperature 
control board and measure the millivolt output of these 
leads.  Refer to chart in page 25 for proper readings.  
If the thermocouple probe checks good, then the 
problem is usually with the temperature control board. 

Indicator light is on, 
but no main 
flame(Model 1456-
1457) 

Solenoid Valve 

If output voltage is present at temperature control 
board, check for voltage at solenoid valve.  If voltage 
is present, listen for valve to open and close.  Also 
check for opens, shorts in coil. Replace as needed. 

Indicator light is on, 
but no main flame 
(1474-1475-1476) 

Temperature Control 

Check for 120 VAC across L1 and L2 on temperature 
control board. If no voltage is present, retrace wiring 
back to power supply. Turn the temperature 
adjustment knob to the maximum temperature 
position and check for 220 VAC at the   load terminal 
to neutral.  If 220 VAC is not present, proceed as 
follows: If 220 VAC is present, and unit is not heating, 
see "Flame Monitor". Check for 220 VAC at terminal 
"COM" on temperature control board.  If no voltage is 
present, trace wiring back to ignition control. 

Содержание Impinger 1450

Страница 1: ...GER CONVEYOR OVENS MODEL 1400 SERIES ADVANTAGE Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l F...

Страница 2: ...5 220 240 VAC 50 HZ L P GAS 6 MODEL 1476 220 240 VAC 50 HZ TOWN GAS 6 SCHEMATIC 1450 1451 1480 7 SCHEMATIC 1452 1453 8 SCHEMATIC 1454 1455 9 SCHEMATIC 1456 1457 10 SCHEMATIC 1474 1475 1476 11 TROUBLES...

Страница 3: ...n the main gas valve is energized TEMPERATURE CONTROL When the centrifugal switch of the main fan motor closes 120 VAC is applied to the temperature controller The temperature dial is adjusted to the...

Страница 4: ...O COOL DOWN When the temperature in the control box reaches 120 F 3 49 C 1 7 C the cooling fan thermostat will switch power to the cooling fan The thermostat will interrupt power to the cooling fan wh...

Страница 5: ...ure switch through the gas pressure proving switch through the normally closed Hi Limit Thermostat to the ignition control The combustion motor is now energized The normally open combustion air switch...

Страница 6: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 6 SCHEMATIC 1450 1451 1480...

Страница 7: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 7 SCHEMATIC 1452 1453...

Страница 8: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 8 SCHEMATIC 1454 1455...

Страница 9: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 9 SCHEMATIC 1456 1457...

Страница 10: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 10 SCHEMATIC 1474 1475 1476...

Страница 11: ...un replace fan assembly Incoming Power Supply Check breakers Reset if needed Check for incoming power at cooling fan thermostat Cooling Fan Thermostat Check cooling fan thermostat thermostat closes at...

Страница 12: ...oven If no pilot flame is visible check pilot shut off valve Pilot Shut off Valve Check to see that pilot shut off valve is open shut off valve is located between valve assembly and burner Pilot Tube...

Страница 13: ...nsformer Secondary Light 4 in 24 VAC at terminal 6 of Ignition control valve Light 5 in 24 VAC at terminal 3 of Ignition control valve Light 6 in 24 VAC at terminal 1 of Ignition control valve CODE Al...

Страница 14: ...ld be approximately 100 VDC 3 The board output is steady If the board voltage output is unsteady beyond limits 3 then the board is probably bad Always check the speed pot be sure it is okay before cha...

Страница 15: ...ils and wires are okay replace ignition control Burner Blower Motor Check for line voltage to motor WITH POWER OFF turn blower wheel to check for locked rotor or blower wheel slippage If proper line v...

Страница 16: ...eck reset button on ignition control if all above are okay replace ignition control Gas Control Relay Check for 220 VAC to relay coil If no voltage is present trace wiring back to ignition control If...

Страница 17: ...f no voltage is present trace wiring back to relay If voltage is present listen for valve to open and close Check for opens or shorts in coil Replace as needed Main Flame will not stay lit Flame Monit...

Страница 18: ...FF turn fan blade to check for locked rotor Check for power to cooling fan If voltage is present at the fan motor and the fan does not run replace fan assembly Incoming Power Supply Check circuit brea...

Страница 19: ...all readings are not correct replace elements as needed Oven heats with switch off Mercury Contactor s The mercury contactor has probably malfunctioned in the closed position If there is no voltage t...

Страница 20: ...es irregular speed Conveyor speed varying Power Supply Check power supply at the DC control board for the 120 VAC at board terminals L1 and L2 If voltage is not present check main circuit breakers DC...

Страница 21: ...re removal to aid in reassembly 7 Remove the eight 8 hex head bolts from the motor mount and slide the motor assembly out of the oven back 8 Remove motor by taking off motor clamp and removing the fou...

Страница 22: ...ontrol panel top and front cover 3 Remove lead wires and mark for reassembly 4 Remove two 2 screws and remove thermostat 5 Reassemble in reverse order MERCURY CONTACTOR 1 Shut off power at main breake...

Страница 23: ...rol note wire numbers and location for reassembly 3 Remove Two 2 screws from control Shut off power at main breaker and replace 4 Reassemble in reverse order and check system operation BURNER ASSEMBLY...

Страница 24: ...VALVE 1 Shut off power at main breaker 2 Shut off gas supply 3 Remove control panel top and front cover 4 Remove gas control valve See GAS CONTROL VALVE 5 Disconnect wires from solenoid valve 6 Remove...

Страница 25: ...uld be 1 134 When using the following chart the temperature at the terminal connections must be noted This temperature is called the Junction Temperature The following chart lists the thermocouple mil...

Страница 26: ...d front cover 3 Remove two 2 top screws and loosen one 1 bottom screw from control assembly 4 Disconnect wiring Push on connectors from control board note proper location of connectors for reinstallat...

Страница 27: ...ff power at main breaker 2 Remove control panel top and front panel 3 Remove gas valve assy 4 Remove two 2 nuts from burner orifice bracket 5 Disconnect pipe union 6 Remove assembly and replace main o...

Страница 28: ...the unit 3 Remove the four 4 screws from the incoming nipple mounting bracket 4 Remove incoming nipple 5 Disconnect two 2 plugs 1 3 prong and 1 4 prong Note location 6 Disconnect pipe union just above...

Страница 29: ...in reverse order and check system operation SOLENOID VALVE REPLACEMENT 1 Remove control panel top and front cover 2 Disconnect pipe union just above gas valve assembly 3 Disconnect two 2 wires from so...

Страница 30: ...pport Assy R 369057 Support Bracket Pins S 369643 Strike Assy T 1009 Oven Top U 369062 Top Control Panel V 369140 Compression Spring W 369903 Washer Flat X 369141 Conveyor Hold Down Bracket Y 369139 S...

Страница 31: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 31 GENERAL 1450 SERIES BLOW UP...

Страница 32: ...U 369804 Knob Clear Skirt V 369202 Pilot Shield Main W 369144 Pilot Shield Extension X 369263 Gas Valve Body only NAT LP for 1450 1451 370025 Gas Valve for 1480 Y 369334 Pilot Shut off Valve Z 369398...

Страница 33: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 33 CONTROL BOX 1450 1451 1480 BLOW UP...

Страница 34: ...or N 369838 Thermostat Hi Limit O 370112 Box Electric P 353014 Supply Terminal Ground Q 369801 Thermostat Temperature Control R 350224 Lens Yellow S 369154 7 AMP Circuit Breaker T 369125 Terminal Bloc...

Страница 35: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 35 CONTROL BOX 1452 1453 BLOW UP...

Страница 36: ...mer P 369803 Control Conveyor Q 369838 Thermostat Hi Limit R 369801 Thermostat Temperature Control S 350224 Lens Yellow T 369154 7 Amp Circuit Breaker U 369125 Terminal Block V 369523 Relay Motor Powe...

Страница 37: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 37 CONTROL BOX 1454 1455 BLOW UP...

Страница 38: ...ulti Block V 369570 Connector 3 Pole W 369571 Connector 4 Pole X 369398 Solenoid Valve 1456 1457 369889 Solenoid Valve 1474 1475 1476 Y 369702 Main Burner Orifice NAT 369099 Main Burner Orifice LP 370...

Страница 39: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 39 CONTROL BOX 1456 1457 1474 1475 1476 BLOW UP...

Страница 40: ...B 369800 Motor Main Fan 60 Hz 369214 Motor Main Fan 50 Hz C 369033 Motor Clamp D 369215 Motor Support Assy E 369192 Capacitor 7 5 MFD F 369306 Oven Back Assy Gas G 369646 Stand Off H 369647 Inlet Pane...

Страница 41: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 41 OVEN BACK GAS ELECTRIC BLOW UP...

Страница 42: ...yor Belting 370092 Conveyor Belting 1 Foot Section B 369825 Retaining Ring C 369813 Conveyor Bearing Block D 369314 Roll Conveyor Notched E 369812 Conveyor Idler Shaft F 369160 Conveyor Pan Stop G 369...

Страница 43: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 43 CONVEYOR 1450 SERIES BLOW UP...

Страница 44: ...Int l 44 Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Telephone 260 459 8200 U S Facsimile 888 790 8193 Int l Facsimile 260 436 0735 Techn...

Отзывы: