Thermocouple Probe 

Remove thermocouple leads from the temperature 
control board, and measure the millivolt output of 
these leads. Refer to charts on page 25 in the 
adjustment section for proper readings. 

Temperature Control 

Turn temperature control dial to full "on" position. 
NOTE: Thermocouple must be connected. Measure 
for 120 VAC across terminals "N.O." and Com., if 
voltage is not present; replace control. 

Solenoid Valve 

If voltage is present at terminals "N.O." and Com., 
check for voltage at solenoid valve. If voltage is 
present, listen for valve to open and close. Also, 
check for opens and shorts in coil. If solenoid valve is 
defective, replace. 

Intermittent Heating 

AS FOLLOWS 

Both the main fan motor and burner blower motor are 
equipped with thermo-protection and will cease to 
operate when not cooled properly. This can cause 
the units to cycle on and off intermittently. Also, most 
of the problems listed under "oven will not heat" can 
cause intermittent failures. 

 
For continuing intermittent problems, a series of test lights may be made and installed in the ovens. The lights will allow the 
customer to advise the service technician a trouble code when the oven fails 
 
The lights should be connected in the following manner: 
 
Light#1 attached in 120 VAC line after oven fan switch. 
Light #2 attached after 120 VAC contacts of oven motor centrifugal switch 
Light #3 in 24 VAC Burner Transformer Secondary. 
Light #4 in 24 VAC at terminal #6 of Ignition control valve. 
Light #5 in 24 VAC at terminal #3 of Ignition  control valve. 
Light #6 in 24 VAC at terminal #1 of Ignition control valve. 

CODE:

 

All lights off - lights of main power, main fan off, oven fan switch out. 
1 on 2 off 3 off 4 off 5 off 6 off - Oven Motor Centrifugal Switch open 
1 on 2 on 3 on 4 off 5 off 6 off - Burner Motor Centrifugal Switch bad. 
1 on 2 on 3 on 4 on 5 0ff 6 off - Ignition Control bad 
1 on 2 on 3 on 4 on 5 on 6 off - Pilot Shield missing or warped, no flame rectification, Pilot 
 

- Orifice plugged, or Gas Control Valve bad. 

1 on 2 on 3 on 4 on 5 on 6 on - Unit still not working Main Orifice plugged, Gas Valve bad, 
 

- Temperature Control bad. 

-

 

However, Main Orifice would not be intermittent problem. 

 

Voltage Supply 

Check incoming voltage supply at line 1 to neutral.  
There should be a voltage reading of 120 VAC. If not 
present, check breakers. 

3 Amp Fuse 

This control fuse is located on the front panel. 
Replace if defective. 

Fuseholder 

Check and/or replace. 

Fan Switch 

See procedure for checking on page 11. 

Conveyor will not run 

Speed Adjustment 
Potentiometer 

This is a 0 to 10 K ohm, 1 turn potentiometer. With 
power off, remove the black and white pot leads from 
the motor control board at terminals P1, P2. Place the 
meter leads on the black lead (P2) and on the white 
lead (P1). Rotating the pot., slowly, from low to high, 
the meter reading should show an even transition 
from 0 to 10K ohms ± 5%. There should be no dead or 
open spots through out the 1 turn of the pot. Check 
both leads to ground. There should be no continuity to 
ground. If any of the above checks fail, replace the 
pot. 

Содержание Impinger 1450

Страница 1: ...GER CONVEYOR OVENS MODEL 1400 SERIES ADVANTAGE Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l F...

Страница 2: ...5 220 240 VAC 50 HZ L P GAS 6 MODEL 1476 220 240 VAC 50 HZ TOWN GAS 6 SCHEMATIC 1450 1451 1480 7 SCHEMATIC 1452 1453 8 SCHEMATIC 1454 1455 9 SCHEMATIC 1456 1457 10 SCHEMATIC 1474 1475 1476 11 TROUBLES...

Страница 3: ...n the main gas valve is energized TEMPERATURE CONTROL When the centrifugal switch of the main fan motor closes 120 VAC is applied to the temperature controller The temperature dial is adjusted to the...

Страница 4: ...O COOL DOWN When the temperature in the control box reaches 120 F 3 49 C 1 7 C the cooling fan thermostat will switch power to the cooling fan The thermostat will interrupt power to the cooling fan wh...

Страница 5: ...ure switch through the gas pressure proving switch through the normally closed Hi Limit Thermostat to the ignition control The combustion motor is now energized The normally open combustion air switch...

Страница 6: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 6 SCHEMATIC 1450 1451 1480...

Страница 7: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 7 SCHEMATIC 1452 1453...

Страница 8: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 8 SCHEMATIC 1454 1455...

Страница 9: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 9 SCHEMATIC 1456 1457...

Страница 10: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 10 SCHEMATIC 1474 1475 1476...

Страница 11: ...un replace fan assembly Incoming Power Supply Check breakers Reset if needed Check for incoming power at cooling fan thermostat Cooling Fan Thermostat Check cooling fan thermostat thermostat closes at...

Страница 12: ...oven If no pilot flame is visible check pilot shut off valve Pilot Shut off Valve Check to see that pilot shut off valve is open shut off valve is located between valve assembly and burner Pilot Tube...

Страница 13: ...nsformer Secondary Light 4 in 24 VAC at terminal 6 of Ignition control valve Light 5 in 24 VAC at terminal 3 of Ignition control valve Light 6 in 24 VAC at terminal 1 of Ignition control valve CODE Al...

Страница 14: ...ld be approximately 100 VDC 3 The board output is steady If the board voltage output is unsteady beyond limits 3 then the board is probably bad Always check the speed pot be sure it is okay before cha...

Страница 15: ...ils and wires are okay replace ignition control Burner Blower Motor Check for line voltage to motor WITH POWER OFF turn blower wheel to check for locked rotor or blower wheel slippage If proper line v...

Страница 16: ...eck reset button on ignition control if all above are okay replace ignition control Gas Control Relay Check for 220 VAC to relay coil If no voltage is present trace wiring back to ignition control If...

Страница 17: ...f no voltage is present trace wiring back to relay If voltage is present listen for valve to open and close Check for opens or shorts in coil Replace as needed Main Flame will not stay lit Flame Monit...

Страница 18: ...FF turn fan blade to check for locked rotor Check for power to cooling fan If voltage is present at the fan motor and the fan does not run replace fan assembly Incoming Power Supply Check circuit brea...

Страница 19: ...all readings are not correct replace elements as needed Oven heats with switch off Mercury Contactor s The mercury contactor has probably malfunctioned in the closed position If there is no voltage t...

Страница 20: ...es irregular speed Conveyor speed varying Power Supply Check power supply at the DC control board for the 120 VAC at board terminals L1 and L2 If voltage is not present check main circuit breakers DC...

Страница 21: ...re removal to aid in reassembly 7 Remove the eight 8 hex head bolts from the motor mount and slide the motor assembly out of the oven back 8 Remove motor by taking off motor clamp and removing the fou...

Страница 22: ...ontrol panel top and front cover 3 Remove lead wires and mark for reassembly 4 Remove two 2 screws and remove thermostat 5 Reassemble in reverse order MERCURY CONTACTOR 1 Shut off power at main breake...

Страница 23: ...rol note wire numbers and location for reassembly 3 Remove Two 2 screws from control Shut off power at main breaker and replace 4 Reassemble in reverse order and check system operation BURNER ASSEMBLY...

Страница 24: ...VALVE 1 Shut off power at main breaker 2 Shut off gas supply 3 Remove control panel top and front cover 4 Remove gas control valve See GAS CONTROL VALVE 5 Disconnect wires from solenoid valve 6 Remove...

Страница 25: ...uld be 1 134 When using the following chart the temperature at the terminal connections must be noted This temperature is called the Junction Temperature The following chart lists the thermocouple mil...

Страница 26: ...d front cover 3 Remove two 2 top screws and loosen one 1 bottom screw from control assembly 4 Disconnect wiring Push on connectors from control board note proper location of connectors for reinstallat...

Страница 27: ...ff power at main breaker 2 Remove control panel top and front panel 3 Remove gas valve assy 4 Remove two 2 nuts from burner orifice bracket 5 Disconnect pipe union 6 Remove assembly and replace main o...

Страница 28: ...the unit 3 Remove the four 4 screws from the incoming nipple mounting bracket 4 Remove incoming nipple 5 Disconnect two 2 plugs 1 3 prong and 1 4 prong Note location 6 Disconnect pipe union just above...

Страница 29: ...in reverse order and check system operation SOLENOID VALVE REPLACEMENT 1 Remove control panel top and front cover 2 Disconnect pipe union just above gas valve assembly 3 Disconnect two 2 wires from so...

Страница 30: ...pport Assy R 369057 Support Bracket Pins S 369643 Strike Assy T 1009 Oven Top U 369062 Top Control Panel V 369140 Compression Spring W 369903 Washer Flat X 369141 Conveyor Hold Down Bracket Y 369139 S...

Страница 31: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 31 GENERAL 1450 SERIES BLOW UP...

Страница 32: ...U 369804 Knob Clear Skirt V 369202 Pilot Shield Main W 369144 Pilot Shield Extension X 369263 Gas Valve Body only NAT LP for 1450 1451 370025 Gas Valve for 1480 Y 369334 Pilot Shut off Valve Z 369398...

Страница 33: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 33 CONTROL BOX 1450 1451 1480 BLOW UP...

Страница 34: ...or N 369838 Thermostat Hi Limit O 370112 Box Electric P 353014 Supply Terminal Ground Q 369801 Thermostat Temperature Control R 350224 Lens Yellow S 369154 7 AMP Circuit Breaker T 369125 Terminal Bloc...

Страница 35: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 35 CONTROL BOX 1452 1453 BLOW UP...

Страница 36: ...mer P 369803 Control Conveyor Q 369838 Thermostat Hi Limit R 369801 Thermostat Temperature Control S 350224 Lens Yellow T 369154 7 Amp Circuit Breaker U 369125 Terminal Block V 369523 Relay Motor Powe...

Страница 37: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 37 CONTROL BOX 1454 1455 BLOW UP...

Страница 38: ...ulti Block V 369570 Connector 3 Pole W 369571 Connector 4 Pole X 369398 Solenoid Valve 1456 1457 369889 Solenoid Valve 1474 1475 1476 Y 369702 Main Burner Orifice NAT 369099 Main Burner Orifice LP 370...

Страница 39: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 39 CONTROL BOX 1456 1457 1474 1475 1476 BLOW UP...

Страница 40: ...B 369800 Motor Main Fan 60 Hz 369214 Motor Main Fan 50 Hz C 369033 Motor Clamp D 369215 Motor Support Assy E 369192 Capacitor 7 5 MFD F 369306 Oven Back Assy Gas G 369646 Stand Off H 369647 Inlet Pane...

Страница 41: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 41 OVEN BACK GAS ELECTRIC BLOW UP...

Страница 42: ...yor Belting 370092 Conveyor Belting 1 Foot Section B 369825 Retaining Ring C 369813 Conveyor Bearing Block D 369314 Roll Conveyor Notched E 369812 Conveyor Idler Shaft F 369160 Conveyor Pan Stop G 369...

Страница 43: ...Impinger I 1400 Series Advantage Service Manual Dom Int l 43 CONVEYOR 1450 SERIES BLOW UP...

Страница 44: ...Int l 44 Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Telephone 260 459 8200 U S Facsimile 888 790 8193 Int l Facsimile 260 436 0735 Techn...

Отзывы: