Troubleshooting

Condition

Possible Cause

Corrective Action

Pump does not run.

Pump is seized or damaged.

Dismantle the pump and repair 
defective or seized component.  
See disassembly and assembly 
procedure.

Incorrect polarity.

Check to ensure red motor lead is 
connected to the positive battery terminal.

Pump speeds up or runs erratically. Low level of grease or reservoir 

Refill reservoir.

is empty.
Follower plate is stuck and separated

Check follower plate and container

from grease.

for damage.

Pump piston or checks are worn.

Disassemble the pump and repair.

Pump runs, but output is low.

Pump speed set too low.

Increase motor speed setting.

Faulty inlet (25, 27) , faulty discharge

Replace faulty components. 

check (18, 19) or damaged O-ring (26).

Weepage from housing cover 30.

Cup seal (15) or O-Ring (13b) wore out. Check the seals and replace if 

necessary.

Pump becomes noisy.

No crank case oil.

Add crank case oil. Remove crankcase 
cover (30) from Pump Housing (67).
Oil level should be at the middle of 
the crankshaft (37).  Check dipstick (30a)
to verify.
If unit is used in cold climates, use 
Mobil Arrow HFA Hydraulic Oil in
crankcase.

Worn wrist pin bushing (12).

Check the bushings and replace if
necessary.

Pump does not build pressure.

Foreign material holding lower 

Dismantle & clear check. Consider 

check open.

installing inlet screen 272180 
before returning pump to service.

Motor runs, but no pump outlet. Gearset or adapter shaft stripped or Dismantle and replace damaged

broken.

part.

Содержание 276041

Страница 1: ...23A Form 403751 JULY 2008 FlowMaster 12 VDC Rotary Driven Electric Pump Series A Model 276041 5 Gal Size Foreign Patent Pending U S Patent Pending This FlowMaster Conforms to the European Directive fo...

Страница 2: ...nd service center nearest you for repair or adjustments other than maintenance specified in this manual Annual inspection by the factory authorized warranty and ser vice center nearest you is recommen...

Страница 3: ...lecting and installing system components Contact your Lincoln Industrial representative for assistance in designing a system to suit your specific needs The pump was tested in light weight oil which w...

Страница 4: ...2 With the pump in a full container of lubricant energize the pump Make sure all air has been expelled from the pump and even lubricant flow is achieved 3 Reattach the pump outlet line Never allow the...

Страница 5: ...Page Number 5 Form 403751 FlowMaster Rotary Driven Electric Pump Illustration 3...

Страница 6: ...Page Number 6 Form 403751 FlowMaster Rotary Driven Electric Pump 57 56b 58 59 42 51 Page 8 30a 30b 28 29 31 30 67 66 65 64 63 62 61 60 37 38 39 40 41 52 53 54 55 35 34 33 32 56a 37a 36 Illustration 4...

Страница 7: ...Page Number 7 Form 403751 FlowMaster Rotary Driven Electric Pump 1 2 3 5 6 4 7 5 3 2 1 8 9 10a 10b 10c 10d 11 12 13a 14 15 16 17 18 13b 20 21 19 26 24 25 27 Illustration 5 10 19a...

Страница 8: ...Page Number 8 Form 403751 FlowMaster Rotary Driven Electric Pump 51 51a 50 47 46 45 44 43 42 47b 47a 48 Illustration 6 First Stage Final Stage...

Страница 9: ...47b 1 Gearset Spacer 272547 14 1 Backup Washer 48 4 Screws 272552 15 1 Cup Seal 50 1 Motor 275979 Polyurethane 51 3 Screw 50051 16 1 Plunger Link Rod 270641 51a 3 Lock Washer 272569 17 1 Spring 52 1 B...

Страница 10: ...set too low Increase motor speed setting Faulty inlet 25 27 faulty discharge Replace faulty components check 18 19 or damaged O ring 26 Weepage from housing cover 30 Cup seal 15 or O Ring 13b wore ou...

Страница 11: ...or Liquid Safety Requirements EN 60204 1 Safety of Machinery Electrical Equipment of Machines Part 1 General Requirements EN 60034 1 Rotating electrical machines Part 1 Rating and performance Declarat...

Страница 12: ...itation or exclusion may not apply to you This warranty gives you specific legal rights You may also have other rights that vary by jurisdiction Customers not located in the Western Hemisphere or East...

Отзывы: