B-4
OPERATION
B-4
7A. ADVANCED PROCESS PANEL
(See Figure 2)
To program Welding modes. Select knob is used to
Scroll through all Welding modes. The Memory button
is used to store and access Welding modes into loca-
tions M1 thru M8.
Modes:
In addition to the 5 welding modes described in
SEC-
TION 7,
the Advance Process Panel allows you to
select the Following additional modes.
•
Constant Power mode
In the Power Mode;
The work point will be in the Volts window. The
Amp window will have
CP
displayed indicating
Constant Power. Once current starts flowing and
during the 5 second “Hold” feature the displays will
show Volts and Amps respectively.
•
Gouge
Air Carbon Arc Cutting (CAC-A) is a physical means
of removing base metal or weld metal by using a
carbon electrode, an electric arc and compressed
air.
INVERTEC® V350-PRO
•
Pulsed Modes
In Pulse Modes;
The work point will be in the Amps window and
should be set close to the wire feed speed of the
wire feeder in inches per minute. The Volts window
will have
SPd
displayed indicating Wire Feed
Speed. Once current starts flowing and during the 5
second “Hold” feature the displays will show amps
and volts.
Pulse Mode features that are displayed while
selecting a Welding pulse mode are listed below;
Steel - .030, .035, .045, .052 – Argon Blends
Stainless Steel - .030, .035, .045 – Argon Blends &
Helium/Argon Blends
Aluminum - .035, 3/64, 1/16 – 4043 & 5356
Metal Core - .045, .052 – Argon Blends
Nickel - .035, .045 – Argon/Helium blends
MEMORY
MEMORY
MEMORY BUTTON
MEMORY BUTTON
(M1 THRU M8)
(M1 THRU M8)
OUTPUT KNOB
OUTPUT KNOB
SELECT BUTTON
SELECT BUTTON
(HOT START OR ARC CONTROL)
(HOT START OR ARC CONTROL)
ADJUST KNOB
ADJUST KNOB
(0 THRU 10-HOT START)
(0 THRU 10-HOT START)
(-10 THRU 0 AND
(-10 THRU 0 AND
0 THRU +10-ARC CONTROL)
0 THRU +10-ARC CONTROL)
SELECT KNOB
SELECT KNOB
(SCOLLS WELDING PROCESSES)
(SCOLLS WELDING PROCESSES)
SELECT
SELECT
ADJUST
ADJUST
SELECT
SELECT
7A
ADVANCE PROCESS PANEL VERSION
REMOTE
REMOTE
ON
ON
REMOTE
REMOTE
LOCAL
LOCAL
WELD TERMINALS
WELD TERMINALS
OUTPUT
OUTPUT
CONTROL
CONTROL
SELECT
SELECT
SELECT
SELECT
MPS
MPS
A
A
OLTS
OLTS
V
V
FIGURE 2