A-8
INSTALLATION
CROSS COUNTRY 300
CONNECTION OF THE LN-25 PIPE TO THE
CROSS COUNTRY 300
Shut off welder before making any electrical connections.
The LN-25 Pipe may be used with the CROSS COUNTRY 300. See
the appropriate connection diagram in Section F.
NOTE
: The LN-25 (K431) Remote Control Module and (K432)
Remote Cable are not recommended for use with the CROSS
COUNTRY 300.
1. Shut the welder off.
2. For electrode Positive, connect the electrode cable from the
LN-25 Pipe to the "+" terminal of the welder and work cable
to the "CV –" terminal of the welder. For electrode Negative,
connect the electrode cable from the LN-25 Pipe to the "CV –"
terminal of the welder and work cable to the "+" terminal of
the welder.
3. Attach the single lead from the front of the LN-25 Pipe to work
using the spring clip at the end of the lead. This is a control
lead to supply current to the wire feeder motor; it does not
carry welding current.
4. Set the MODE switch to the "CV-WIRE " position.
5. Set the "IDLE" switch to the "AUTO" position. When not weld-
ing, the CROSS COUNTRY 300 engine will be at the low idle
speed.
6. When the gun trigger is closed, the current sensing circuit will
cause the CROSS COUNTRY 300 engine to go to the high idle
speed, the wire will begin to feed and the welding process
started. When welding is stopped, the engine will revert to low
idle speed after approximately 12 seconds unless
welding is resumed.
WARNING