MAINTENANCE

X-TRACTOR

®

8A WELDING FUME EXTRACTOR

RETURNING THE TIMER TO THE FACTORY SETTINGS  

Factory settings of each timer: 3sec. ON time, 30min. OFF time,
function ‘A’.  No matter how you change the settings you can always
reset all settings to factory settings following these easy steps: 

1. Disconnect the unit from the power supply. 

2. Press and hold down (off/arrow down) and (TEST) buttons. 

3. Connect the unit to the power supply. 

4. Release the buttons after 'P' appears on the display. 

5. Then 'A' appears on the display - do not press anything. 

6. After a few seconds the unit will resume operation with factory

settings. 

7. Change the presset ON and/or OFF times if required 

OFF-LINE FILTER CLEANING

When the X-TRACTOR 8A is off, the signal to the solenoid valve is
controlled by an additional timer placed inside the cabinet. This timer
keeps the signal on for a certain period of time in order to run two or
three more cleaning cycles after the extraction unit is shut down
(OFF-line cleaning). Inside the filter container, there is a cover that
closes the inlet in order to avoid dust being blown out in the
duct/hose system.

FIGURE 4

The timer is pre-set at the factory to the values in the following table.

Normally it is not necessary to adjust the timer.

13

OFF-LINE CLEANING SPECIFICATIONS

FUNCTION

MULTI-FUNCTION

MOUNTING

DIN-RAIL MOUNTING

DIMENSION

.67” (DIN 43880)

RANGE

0.1 S X - 100 H

SUPPLY

24 - 240 VAC & 24 VDC

CONNECTION

SCREW TERMINAL

I/O SIGNAL

8 A SPDT RELAY

TYPE

SYM. RECYCLER, INTERVAL,

DELAY ON OP./REL.

I/O FUNCTION

7 FUNCTIONS

SETTING OF TIME

SETTING OF TIME RANGE

SETTING OF FUNCTION

TIMER VALUES

FUNCTION

DELAYED OUT

TIME RANGE

60 SEC.

TIME

3 (TOTAL IS 3 X 60 SEC = 3 MIN.)

TIMER SPECIFICATIONS

INTERVAL (OFF) TIME

.01 SEC. - 99 HR.

(note: check response time of your sole-

DISCHARGE (ON) TIME

.01 SEC. - 99 HR.

(note: check response time of your sole-

SUPPLY VOLTAGE

110 – 240V AC/DC 50-60HZ (± 10%) 

48 – 115V AC/DC 50-60HZ (± 10%) 

10-48 V AC/DC 50-60HZ (± 10%)

CURRENT CONSUMPTION

MAX. 7mA 

OPERATING TEMPERATURE

-40ºF TO +140ºF (-40ºC TO +60ºC)

ENVIRONMENTAL PROTECTION

IP65 WHEN INSTALLED

CASE MATERIAL

ABS PLASTIC FR GRADE

CONNECTION

DIN 43650A - ISO 4400

INDICATOR

DIGITAL DISPLAY

TIMER CERTIFICATIONS

CE

YES

cULus

YES

RoHS

YES

IP65

YES

Содержание X-Tractor 8A

Страница 1: ... 10 14 Lincoln Global Inc All Rights Reserved For use with machines having Product Numbers K3967 1 K3967 2 K3967 3 Save for future reference Date Purchased Code ex 10859 Serial ex U1060512345 Operator s Manual WARNINGS GENERAL DESCRIPTIONS TECHNICAl SPECIFICATIONS INSTALLATION RECOMMENDED USES OPERATING INSTRUCTIONS MAINTENANCE ACCESSORIES TROUBLESHOOTING GUIDE ...

Страница 2: ...N A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual symptoms see your supervisor Perhaps the welding atmosphere and ventilation system should be checked WEAR CORRECT EYE EAR BODY PROTECTION PROTECT your eyes and face with welding helmet properly fitted...

Страница 3: ... hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and devices in position and in good repair Keep hands hair clothing and tools away from V belts gears fans and all other moving parts when starting operating or repairing equipment 1 e In some cases it ...

Страница 4: ...rm to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with suitable non flammable screening and or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal FUMES AND GASES CAN BE DANGEROUS 5 a Welding may produce fumes a...

Страница 5: ...ent passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow NFPA 51B Standard for Fire Prevention During Welding Cutting and Other Hot Work available from NFPA 1 Batterymarch Park PO box 9101 Quincy MA 022690 9101 6 j Do not use a welding power source for pipe...

Страница 6: ...l device used to capture welding fume at or near the arc and filter conta minants out of the air The ventilation or exhaust needed for your application depends upon many factors such as Workspace volume Workspace configuration Number of welders Welding process and current Consumables used mild steel hardfacing stainless etc Allowable levels TLV PEL etc Material welded including paint or plating Na...

Страница 7: ...site at http www aws org Supplemental Information Not listed Nuisance value maximum is 10 milligrams per cubic meter PEL value for iron oxide is 10 milligrams per cubic meter TLV value for iron oxide is 5 milligrams per cubic meter As respirable dust Subject to the reporting requirements of Sections 311 312 and 313 of the Emergency Planning and Community Right to Know Act of 1986 and of 40CFR 370 ...

Страница 8: ...Operating Instructions 11 Automatic Filter Cleaning 11 Off Line Filter Cleaning 13 Maintenance Safety Precautions 14 Filter Container 14 Changing Filter Cartridge 14 Draining Of Pneumatic Tank 14 Greasing Of Bearings 14 Belt Tightening 14 Accessories Accessories 15 Troubleshooting Troubleshooting Guide 16 Wiring Diagrams 17 Parts For most current part list visit parts lincolnelectric com ...

Страница 9: ...tside surface of the filter so that it falls into the dustbin This air jet is released from an on board tank of compressed air that is pressurized from an external source through a fitting on the front of the machine Unit includes Filter Cartridge Automatic Filter Cleaning System Automatic Operation Connection TECHNICAL SPECIFICATIONS NOTE Technical specifications are subject to change without pri...

Страница 10: ...ble to external start stop switches If applicable 4 Apply the correct input power Only qualified personnel should perform this function RECOMMENDED USES Read and understand this entire section before operating your X TRACTOR 8A Always operate this equipment with the filters installed and covers in place as these provide maximum protection from moving parts and insure proper vacuum operation and co...

Страница 11: ...l capacity at all times The system consists of a compressed air tank solenoid valve and a timer The tank is filled with compressed air The solenoid valve opens at certain intervals set at the timer and compressed air is blown into the filter Dust stuck on the outside of the filter is blown off and into the dustbin The tank is then again filled with compressed air awaiting the next cycle This cycle...

Страница 12: ...dy for operation CHANGING THE TIMER FUNCTION The D LUX timer is able to perform the following functions Function A start with the ON time and then the OFF time etc Function C start with the OFF time and then the ON time etc Function B single shot starts with the ON time and then switches OFF indefinite Function D single shot starts with the OFF time and then switches ON indefinite Function E start...

Страница 13: ...lter container there is a cover that closes the inlet in order to avoid dust being blown out in the duct hose system FIGURE 4 The timer is pre set at the factory to the values in the following table Normally it is not necessary to adjust the timer 13 OFF LINE CLEANING SPECIFICATIONS FUNCTION MULTI FUNCTION MOUNTING DIN RAIL MOUNTING DIMENSION 67 DIN 43880 RANGE 0 1 S X 100 H SUPPLY 24 240 VAC 24 V...

Страница 14: ...00 running hours The filter should be inspected regularly Damaged filters must be replaced immediately Proceed as follows 1 Disconnect input power 2 Remove four of the screws for the main cover of the unit Tilt the cover forward 3 Disconnect compressed air and drain the compressed air tank in order to empty The drain valve is situated at the lower rear end behind the dust bin 4 Disconnect the coil...

Страница 15: ...luded NKT Nozzle Kit Order K2389 3 The NKT nozzle kit provides extraction capacity to standard welding guns It is designed for mounting the extraction hose on top of the welding gun Hose dimension is 8 ft 2 5 m x 1 in 25 mm O D Includes a 1 3 4 in 45 mm O D hose adapter NKC Nozzle Kit Order K2389 4 The NKC nozzle kit provides extraction capacity to standard welding guns by circular extraction whic...

Страница 16: ...ce hoses Too many nozzles connected simultaneously Use fewer nozzles Motor running in wrong direction Change position of any 2 input phases at connection to machine Leakage in the system Find the leakage and repair MOTOR PROTECTION CUTTING OUT Motor running on two phases Call for an electrician Low voltage on one or several phases Check voltage during operation Extracting too much air Close Outlet...

Страница 17: ...D 2 S1 B F X1 4 S2 X1 S1 Drift 0 1 2 Cleaning Off On 1 X1 T1 7 15 18 14 X1 3 START K1 13 BLAD 2 T2 A1 X1 5 X1 1 T2 18 15 44 F1 NO P F2 43 KT1 68 44 X1 43 8 TV1 67 X1 9 X0 1 2 3 1 2 3 4 1A 2A 3 4 4B 5B Drift Auto Man NOTE This diagram is for reference only It may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of...

Страница 18: ...1 Drift 0 1 2 Cleaning Off On 1 X1 T1 7 15 18 14 X1 3 START K1 13 BLAD 2 T2 A1 X1 5 X1 1 T2 18 15 44 F1 NO P F2 43 KT1 68 44 X1 43 8 TV1 67 X1 9 X0 1 2 3 1 2 3 4 1A 2A 3 4 4B 5B Drift Auto Man Draw no 2 6 7 0 8 26 1 028 99 0 8 08 2 8 8 2 9 028 8 8 99 2 2 76 0 2 0 30 2 2 6 7 26 1 HOLGER S AS 8 5 A8 2 5 A B 7 B C EXTRACTION UNIT AVSUGSENHET 5 0 5 8 5 3 0 028 4 080 8 AS OLGER S A 4 D E 5 F ...

Страница 19: ... A1 A1 K1 A2 A2 KT1 K2 T2 A1 BLAD 2 A1 F4 24 TR1 0 90VA 24VAC 4A BLAD 2 T2 A2 Y1 start A2 T1 MV1 SOLENOID VALVE FILTER CLEANING TIMER CLEANING DELAYED OUT TIMER RENSING FORSINKET UT K2 RELAY FAN 2 KONTAKTOR VIFTE 1 K1 RELAY FAN 1 KONTAKTOR VIFTE 1 MAGNETVENTIL FILTER MV1 24VAC T1 1 5mm2 575VAC 60HZ 1 5mm2 4mm2 F1 F2 5 3 1 1 5mm2 6 4 2 V1 W2 U1 1 5mm2 PE 5 1 5mm2 1 3 6 1 5mm2 PE W2 2 U1 4 V1 K1 K2 ...

Страница 20: ...20 DIAGRAMS X TRACTOR 8A WELDING FUME EXTRACTOR 0 X1 11 MS1 MS2 MS3 AUTO START STOP X1 10 MS4 22 21 MSX 1 2 3 14 2 K1 13 BLAD 1 BLAD 1 T1 A2 24VAC 1 2 5 2 5 1 5 ...

Страница 21: ...STE BOKS TO NEXT BOX SW ITCH MS3 MS4 MICROSW ITCH 3 4 W IRING BETWEEN KABLING MELLOM CONNECTION BOXES KOBLINGSBOKSER 2x0 75mm2 WIRING BETWEEN KABLING MELLOM CONNECTION BOXES KOBLINGSBOKSER TO NEXT MICROSWITCH W IRING TO KOBLING TIL CONROLBOX ON MB 1000 STYRESKAP MB 2x0 75mm2 STYREBOKS PÅ MB CONTROLBOX ON MB UNIT 11 AUTO START STOP 10 KOBLET TIL CONNECTED TO TERMINAL X1 10 and 11 X1 22 21 KABLING T...

Страница 22: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra l Ne laissez ni la peau ni des vête ments mouillés entrer en contact avec des pièces sous tension l Isolez vous du travail et de la terre l Berühren Sie keine stromführenden Teile oder Elektroden mit ...

Страница 23: ... und Entlüftung des Arbeitsplatzes l Mantenha seu rosto da fumaça l Use ventilação e exhaustão para remover fumo da zona respiratória l Turn power off before servicing l Desconectar el cable de ali mentación de poder de la máquina antes de iniciar cualquier servicio l Débranchez le courant avant l entre tien l Strom vor Wartungsarbeiten abschalten Netzstrom völlig öff nen Maschine anhalten l Não o...

Страница 24: ...advice once it has been given nor does the provision of information or advice create expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive manufacturer but the selection and use of specific products sold by Lincoln Electric is solely within the control of and remains the sole responsibility of the customer Many variables beyond the control of Lincol...

Отзывы: