Lincoln Electric Wire Feed Module 12207 Скачать руководство пользователя страница 3

SECTION A:

WARNINGS

  

CALIFORNIA PROPOSITION 65 WARNINGS

WARNING: 

Breathing diesel engine exhaust

exposes you to chemicals known to the State
of California to cause cancer and birth defects,

or other reproductive harm.

• Always start and operate the engine in a 

well-ventilated area.

• If in an exposed area, vent the exhaust to the outside.
• Do not modify or tamper with the exhaust system. 
• Do not idle the engine except as necessary.

For more information go to 

www.P65 warnings.ca.gov/diesel

WARNING: This product, when used for welding or
cutting, produces fumes or gases which contain
chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California
Health & Safety Code § 25249.5 

et seq.)

WARNING: Cancer and Reproductive Harm
www.P65warnings.ca.gov

ARC WELDING CAN BE HAZARDOUS. PROTECT
YOURSELF AND OTHERS FROM POSSIBLE SERIOUS
INJURY OR DEATH. KEEP CHILDREN AWAY. 
PACEMAKER WEARERS SHOULD CONSULT WITH
THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For
additional safety information, it is strongly recommended 
that you purchase a copy of “Safety in Welding & Cutting - 
ANSI Standard Z49.1” from the American Welding Society, 
P.O. Box 351040, Miami, Florida 33135 or CSA Standard 
W117.2-1974. A Free copy of “Arc Welding Safety” booklet 
E205 is available from the Lincoln Electric Company, 
22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION,
MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE POWERED

EQUIPMENT.

   1.a. Turn the engine off before troubleshooting

and maintenance work unless the
maintenance work requires it to be running.

   1.b. Operate engines in open, well-ventilated areas or vent the engine

exhaust fumes outdoors.

   1.c. Do not add the fuel near an open flame welding

arc or when the engine is running. Stop the
engine and allow it to cool before refueling to
prevent spilled fuel from vaporizing on contact

with hot engine parts and igniting. Do not spill fuel when filling
tank. If fuel is spilled, wipe it up and do not start engine until
fumes have been eliminated.

   1.d.  Keep all equipment safety guards, covers 

and devices in position and in good repair.
Keep hands, hair, clothing and tools away 
from V-belts, gears, fans and all other 
moving parts when starting, operating or
repairing equipment.

   1.e. In some cases it may be necessary to remove safety guards to

perform required maintenance. Remove guards only when
necessary and replace them when the maintenance requiring
their removal is complete. Always use the greatest care when
working near moving parts.

   1.f.  Do not put your hands near the engine fan. Do not attempt to

override the governor or idler by pushing on the throttle control
rods while the engine is running.

   1.g. To prevent accidentally starting gasoline engines while turning

the engine or welding generator during maintenance work,
disconnect the spark plug wires, distributor cap or  magneto wire
as appropriate.

   1.h. To avoid scalding, do not remove the radiator

pressure cap when the engine is 

hot.

ELECTRIC AND

MAGNETIC FIELDS MAY

BE DANGEROUS

   2.a. Electric current flowing through any conductor

causes localized Electric and Magnetic Fields (EMF). 
Welding current creates EMF fields around welding cables 
and welding machines

   2.b. EMF fields may interfere with some pacemakers, and 

welders having a pacemaker should consult their physician
before welding.

   2.c. Exposure to EMF fields in welding may have other health effects

which are now not known.

   2.d. All welders should use the following procedures in order to

minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure

them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work

cables. If the electrode cable is on your right side, the
work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as pos-

sible to the area being welded.

2.d.5. Do not work next to welding power source.

SAFETY

Safety 02 of 04 - 5/16/2018

Содержание Wire Feed Module 12207

Страница 1: ...achines having Code Numbers 12207 Need Help Call 1 888 935 3877 to talk to a Service Representative Hours of Operation 8 00 AM to 6 00 PM ET Mon thru Fri After hours Use Ask the Experts at lincolnelec...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and...

Страница 4: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with s...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...ri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan...

Страница 7: ...nection of Lincoln Electric Wire Feeders A 8 OPERATION Section B Design Features B 1 Recommended Wire Feeders and Accessories B 1 Additional Safety Precautions B 1 Wire Feed Module Operation B 1 MAINT...

Страница 8: ...ectrode welding and other open arc processes With the module installed the welder can be easily set to operate in either the constant voltage or the stan dard constant current modes The constant volta...

Страница 9: ...top engine before servicing Keep away from moving parts Only qualified personnel should install use or service this equipment MACHINE GROUNDING Because a portable engine driven welder or generator cre...

Страница 10: ...all Flat Head Screwdriver Pliers 3 32 Allen Wrench 3 8 Drive Ratchet with Small Extension 1 2 Socket 9 16 Deep Well Socket 3 4 Socket 5 16 Nut Driver and Socket 1 2 Open End Wrench 9 16 Open End Wrenc...

Страница 11: ...all wires connected to it mounting tab down INSTALLATION SEQUENCE SAE 300 HE See Exploded View the following Page 1 Remove the bottom 3 mounting screws from the upper control nameplate Keep the screw...

Страница 12: ...ENTIOMETER SPACER AMPHENOL RECEPTACLE MOUNT WITH KEY LOCATED IN THE BOTTOM POSITION POTENTIOMETER SHAFT SEAL CONTROL KNOB CENTER SHAFT SEAL AND SPACER UNDER KNOB AND WITH PRESSURE ON THE KNOB AGAINST...

Страница 13: ...eed power cable assembly through the rectangu lar window on the bottom of the generator 8 Connect power cable thermostat assembly and the existing cables to the negative brushholder using the 75 long...

Страница 14: ...right side of the machine and save hardware 12 Position control box into place Four plastic fuel tank mounting bolts require loosening to slide the tank towards the engine The control box must be mane...

Страница 15: ...e guard from the left side of the welder Using two screws from the mounting hardware package fasten the out put terminal also from the mounting hardware package to the guard Connect the WFM control bo...

Страница 16: ...t processes CONNECTION OF THE LN 7 LN 7 GMA TO THE WIRE FEED MODULE Requires K584 L input cable K864 adapter and optionally the K857 for remote control See the connection diagram in the Diagrams secti...

Страница 17: ...standard output terminal is not used for CV welding of either polarity Refer to diagrams section to determine the correct con nection to the remote control receptacle When the WFM is in the CV mode th...

Страница 18: ...tle linkage will cause an increase in the A C auxiliary voltage If this voltage goes above 140 volts the control circuits of the WFM and wire feeders will be damaged The engine governor setting is pre...

Страница 19: ...do not understand or are unable to perform the Recommended Course of Action safely contact your local Authorized Field Service Facility TROUBLESHOOTING CHART Have qualified personnel do the maintenanc...

Страница 20: ...ion 2 Refer to quick check procedure for generator only 3 Refer to procedure for Checking the Cold Tip Contactor CR4 4 Turn engine off Remove short circuit 5 Broken or loose connections from WFM to co...

Страница 21: ...Capacitors in power source output cir cuit failed A failure is indicated if the small vent plug on the top of a capaci tor is raised or blown out 5 Opening in feedback circuit 6 Faulty P C Board 1 Ch...

Страница 22: ...ion contamination or looseness b Check leads in the plug harness for loose or inter mittent connection 2 If P C Board is visibly damaged electrically before possibly subjecting the new P C Board to th...

Страница 23: ...voltage is present at leads 630 631 measure the voltage between L2 terminal and ter minal opposite L2 If the voltage is equal to the output voltage across the positive and negative output terminals r...

Страница 24: ...the problem exists in the Wire Feed Module Refer to Troubleshooting chart 2 If there is no generator output in step 1 proceed with the following a If jumper plug P10 is available a quick check can be...

Страница 25: ...may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure pan els If the diagram is illegible write to...

Страница 26: ...GATIVE CV OUTPUT TERMINAL PANEL CONNECT TO NEG BRUSH HOLDER 250 AMP THERMOSTAT ASSEMBLY WIRE FEED MODULE ON MACHINE REMOVE PLUG P10 FROM CONNECTOR J5 CONNECT P5 ON W F M TO CONNECTOR J5 ON MACHINE CON...

Страница 27: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra...

Страница 28: ...d Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de ali mentac...

Страница 29: ...tomer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such information or...

Отзывы: