F-1

DIAGRAMS

F-1

Vantage 575

NOTE:

This diagram is for reference only

. It may not be accurate for all machines covered by this manual. 

The specific dia- gram for 

your particular machine is pasted inside the machine on one of

the enclosure panels.

200

200

B

5H

201

200A

201

A

BR

U

S

H

42B

41A

ROT

OR

232L

232K

6

BR

U

S

H

1

5

VOLT METE

R

15

AMMETE

R

PER

IP

H

ERAL B

D

.

W

E

LD

 BOAR

D

270

403

405

208A

+

3 TURNS

THRU

TOROID

PCB3

PCB1

404

G4176

A.

04

METE

R

S

 O

PTION

AL

I

AM

PHE

NOL 2

201

CB

4

CB3

CB

2

5D

5F

5E

B

E

C

6

A

A

U

X

ILIAR

Y G

R

OU

N

D

 STU

D, 

BOTTOM

C

E

NTER  

OF 

C

O

NTR

OL B

O

X

GROUND

 S

T

U

D

 O

N

CON

T

RO

L

 PANE

L

STATO

R LEADS 

"D"& 

"E" ARE 

TAPED AN

TIED I

N

TO

 HARNESS

AU

X

ILIA

R

Y

 PO

W

E

LEAD

S A, B, & C TO PA

SS TH

R

O

U

G

H

TOR

OI

D F

O

U

R

 TIMES 

IN

 DI

R

E

CTI

ON S

H

OWN

.

LEAD 

"3" TO PASS TH

R

O

U

G

H TO

R

O

ID

 TW

O TI

MES IN 

DI

R

E

CTIO

SH

O

W

N

.

260

261

7

9

11

1

8

9

16

J7

J3

6

10

J4

J5

6

10

C

O

NTR

OL, MO

D

E

 SE

L.

C

H

O

P

P

E

R,

PO

W

E

R,

P

W

M,

THERM

AL

 

 

 

271

200

R4

232B

232C

208C

IN

SU

LATE

D N

E

UTR

AL

STU

D O

N

 BOTTOM

RI

GHT OF C

O

NTR

OL 

B

O

X

GN

D

-J

3 TU

R

N

S

THR

U

TOR

OI

D

12 V

OLT GR

O

U

N

D

STU

D O

N

 LEFT 

SI

D

E

BA

C

K

 O

F

 C

O

NTR

OL B

O

X

5N

5S

5L

5M

5T

5G

GN

D

-A

GND

-B

5H

GN

D

-J

L1

  CHOKE

5J

5K

5A

5B

5

5

3

5C

L1

L2

12

L3

GN

D

-L

GN

D

-C

GND

-D

GN

D

-E

VANTAGE 575 WIRING DIAGRAM  (K2170-1 50HZ)

208

B

GN

D

-F

15A

15A

15A

N

A

E

N

A

E

N

A

E

E

N

L1

L2

L3

-+

+

-

3200M

F

C

300V

P

O

SITIVE BR

U

SH 

C

O

N

N

E

C

TE

D

TO SLIP RI

N

G

 N

E

A

R

EST

TO THE LAMIN

ATION

PUL

L

C

OIL

HO

LD

C

OIL

J54

P54

RED

WH

T

BLK

1

2

3

4

232M

SH

UTD

OW

N

SO

LENOID

265

262

226

227

IDLER

SO

LEN

O

ID

232L

4

3

2

1

BLK

WH

T

RE

D

P54

J54

HO

L

D

C

OIL

PU

LL

C

OIL

SH

OWN

 IN

"HI

GH

" PO

SITIO

N

ID

LER

CONT

ROL

262

262A

-

AUT

O

HI

G

H

257

256

232R

+

HO

UR

 ME

T

E

R

232E

2A

4A

4

2

279

10K

277

VIEW

E

D

 F

R

OM 

BA

C

K

77

BA

C

K

FRO

M

VIEW

E

D

76

R1

278

P

INC

H P

O

T

75

CC

W

OUTP

UT CONT

ROL

W

E

LD

IN

G TERM

INAL

CONT

R

O

L S

W

ITCH

SH

OWN

 IN "A

LW

AYS 

O

N

" PO

SITIO

N

PIPE

TIG

CC

CV

41A

ST

ATOR 42V 

W

IN

D

ING

4

A

220

3

2

1

218

S5

214

M

O

DE SELE

CT

OR

SW

ITC

H

222

41

42

10A

CB

6

NEG

NEG

STATO

R

WE

L

D

W

IND

INGS

W1

 &

 W6

W2

 &

 W3

W4

 &

 W5

W6

W6

W1

W1

W4

W5

W4

W5

W3

W3

W2

W2

R

E

CTIFIE

R

BR

ID

GE

NE

G

NE

G

PO

S

PO

S

PO

S

PO

S

B8

B7

B7

B8

B3

B2

B1

B4

B5

B6

LEFT SI

D

E

CH

OPPER

PC

B6

PO

S

NE

G

PO

S

NE

G

W8

W7

25

23

B8

B7

14A

13A

B7

B8

14

13

B3

B2

B1

B4

B5

B6

RIGHT S

ID

E

C

H

OPPE

R

PCB5

NEG

NEG

PO

S

PO

S

25A

23A

W1

0

W9

-

50MV

=

400AMPS

+

204

S

206S

206C

BY

PASS

FI

L

T

E

R

ASSEM

BLY

208B

208A

208

206A

206B

GROUN

D

 S

T

UD

ON

 OU

T

P

U

T

 PA

N

E

L

GND

-K

S

W

ITCH S

H

O

W

N

 IN

P

O

SITIVE POLA

RITY

P

O

SITIO

N

+

POLAR

IT

Y

SW

ITCH

-

206A

21

115VAC

C

O

NTA

CT

OR

W

ORK

42VAC

GROUND

R

EMOTE

C

O

NTR

O

L

J

A

D

C

H

B

K

E

F

G

I

31

32

4B

77B

21

2B

75B

GN

D

-A

41A

42A

76B

AMPHEN

O

L 1

AM

PH

EN

OL 2

R

EMOTE

CO

N

T

RO

L

C

O

NTA

CT

OR

GROUN

D

A

B

C

D

E

F

2B

4B

GN

D

-B

76B

75B

2A

4A

75A

76A

77A

77B

A

MME

T

E

R

M1

M2

M3

M4

M5

M6

M9

M10

VO

L

T

M

ET

ER

M1

M2

M3

M4

M5

M6

M9

M10

M1

M2

M3

M4

M5

M6

M9

M10

220

278 
279

277

214

77

76

75

M1

M2

M3

M4

M5

M6

M9

M10

25

23

208B

256

260

1

9

16

8

 

25A

23A

13

14

257

261

6

12

J2

E

N

GIN

E,PE

RI

P

H

E

R

A

L

232D

226

404

5G

1

16

9

8

2

4

75A

76A

77A

500

J1

AMP

H

E

N

OL,I.

D.

2

1

204

S

206S

J6

SH

U

N

T

ALT

405A

247

243

405

B

405B

GO

LD

SILV

ER

ENG

PROT

9

16

1

8

J31

403

5T

270

262A

405

232F

405A

1

6

7

J32

234

271

247

405B

12

PR

O

G

R

AMMIN

G

3

4

1

J30

6

232M

232N

232

A

232

R

12VD

C

IN

SU

LATED

STU

D

232C

OIL

PR

ESSU

R

E

241

228

5L

229

232B

5M

COOLANT

TEM

PER

A

TUR

E

232K

5K

4

14

1

4

1

J53

J52

J51

FU

EL

4

5

1

8

J43

PU

LL COIL 

B

D

B1

B2

B3

B4

PC

B8

5S

265

232N

227

R

U

N

/STOP

SW

ITCH

S

H

OW

N  

IN "RUN" POS

IT

IO

N

238

B

236A

CB

5

20A

232

232D

232F

236B

232A

232H

STOP

RU

N

ST

ART BUTTO

N

238A

231

COOLANT TE

MPERATURE

SEN

SOR

 & SW

ITC

H

OIL P

R

ESS

U

R

E

SEN

SOR

 & SW

ITCH

SW

ITC

H

SW

ITC

H

235

G

241

228

229

5J

234

235

WK

FU

EL LVL.

SEN

SOR

SEN

SOR

SENSOR

5N

EN

GIN

E

SU

PPO

RT

LEFT SI

D

E

EN

GIN

E BL

O

C

K

+

-

STA

RTIN

G

MOTO

R

ST

ARTER

SOLEN

OID

ALT

ER

N

ATOR

L
P

IG

B

243

231

238A

12V BAT

T

E

R

Y

232

238

2B

2B

2C

2C

2A

2A

L3

L2

L1

8

5C

5B

RC

DI

30mA

A

B

C

1C

1B

1A

20A

CB

1

10

1

7

222

218

31

32

CB

7

10A

3

32A

32A

42A

42B

42V /

 115V S

W

ITCH

250

250

D

3

3

Содержание VANTAGE 575 CUMMINS

Страница 1: ...tantly think before you act and be careful OPERATOR S MANUAL Copyright 2003 Lincoln Global Inc World s Leader in Welding and Cutting Products Sales and Service through Subsidiaries and Distributors Wo...

Страница 2: ...ing ANSI Standard Z49 1 from the American Welding Society PO Box 351040 Miami Florida 33135 or CSA Standard W117 2 1974 or WTIA Welding Technology Institute of Australia PO Box 6165 Silverwater NSW 21...

Страница 3: ...dangerous 5 a Welding may produce fumes and gases hazardous to health Avoid breathing these fumes and gases When welding keep your head out of the fume Use enough ventilation and or exhaust at the arc...

Страница 4: ...xplode 6 f Sparks and spatter are thrown from the welding arc Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap over your hair Wear ear plugs...

Страница 5: ...i s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse panta...

Страница 6: ...terfere with a pacemakers function Generally the interference does not permanently damage the pacemaker Once the wearer leaves the arc welding environment or stops welding the pacemaker returns to nor...

Страница 7: ...e environment is compatible This may require additional protection measures h The time of the day that welding or other activities are to be carried out The size of the surrounding area to be consider...

Страница 8: ...______________________________________________ Code Serial Number _____________________________________________________________ Date of Purchase _______________________________________________________...

Страница 9: ...ions A 6 Connection of Lincoln Electric Wire Feeders A 7 A 8 Operation Section B Safety Instructions B 1 General Description B 1 Recommended Applications B 1 Controls and Settings B 2 Engine Controls...

Страница 10: ...Engine Maintenance D 1 Air Filter D 1 Fuel Filters D 2 Cooling System D 2 Battery Handling D 2 Nameplate Warning Decal Maintenance D 3 Welder Generator Maintenance D 3 Engine Maintenance Components D...

Страница 11: ...0 500 Amps DC multi purpose 40 volts PHYSICAL DIMENSIONS Height 2 Width Depth Weight 1067mm 800mm 1603mm 737kg 42 0 in 31 5in 63 1in 1625lbs Approx CTE Centre Tapped Earth 1 Output rating in watts is...

Страница 12: ...S Where there is a combustible surface directly under stationary or fixed electrical equipment that surface should be covered with a steel plate at least 1 6mm thick which should extend not less than...

Страница 13: ...presentative for any engine adjustments that may be required HIGH TEMPERATURE OPERATION At temperatures above 40 C 104 F output voltage derating may be necessary For maximum output current ratings der...

Страница 14: ...f fuel may require bleeding the fuel injection pump NOTE Before starting the engine open the fuel shutoff valve pointer to be in line with hose FUEL CAP Remove the plastic cap covering from the Fuel T...

Страница 15: ...hru the strain relief bracket provided on the front of the base and connect to the terminals provided These connections should be checked periodically and tightened if necessary Listed in Table A 1 ar...

Страница 16: ...hase outlets are from different phases and cannot be paralleled The auxiliary power receptacles should only be used with three or four wire earthed type plugs or approved double insulated tools The cu...

Страница 17: ...ol lead to supply current to the wire feeder motor it does not carry welding current Control Cable Model Connect Control Cable between Engine Welder and Feeder Set the MODE switch to the CV WIRE posit...

Страница 18: ...or the electrode is not energized until the gun trigger is closed If you are using an LN 25 without an internal contactor the electrode will be energized when the Vantage is started When the gun trigg...

Страница 19: ...nt ADDITIONAL SAFETY PRECAUTIONS Always operate the welder with the hinged door closed and the side panels in place as these provide maximum protection from moving parts and insure proper cooling air...

Страница 20: ...mage to the ring gear and or starter motor 3 HOUR METER The hour meter displays the total time that the engine has been running This meter is a useful indicator for scheduling preventive maintenance 4...

Страница 21: ...to or after starting the engine the engine will operate at full speed for approximately 12 seconds and then go to low idle speed b When the electrode touches the work or power is drawn for lights or t...

Страница 22: ...ircuit current which results in a more forceful digging arc Typically a forceful digging arc is preferred for root and hot passes A softer arc is preferred for fill and cap passes where weld puddle co...

Страница 23: ...l and coolant level Close engine compartment door 3 Remove all plugs connected to the AC power receptacles 4 Set IDLER switch to AUTO 5 Set the RUN STOP switch to RUN Observe that the engine protectio...

Страница 24: ...sition stacking of iron are key to fast travel speeds It is recommended that the ARC CONTROL be set initially at 0 TOUCH START TIG MODE The Vantage can be used in a wide variety of DC TIG welding appl...

Страница 25: ...27 1 When used with argon gas The current ranges shown must be reduced when using argon helium or pure helium shielding gases 2 Tungsten electrodes are classified as follows by the American Welding S...

Страница 26: ...CC STICK position Operation in other modes may produce erratic outputs and large output imbalances between the units AUXILIARY POWER OPERATION Start the engine and set the IDLER control switch to the...

Страница 27: ...G 4 02 mm 12AWG 6 02 mm 10AWG 10 02 mm 8AWG 16 02 mm 6AWG 25 02 mm 4AWG 15 230 3600 18 60 23 75 46 150 69 225 107 350 183 600 20 230 4800 18 60 30 100 53 175 84 275 1373 450 Conductor size is based on...

Страница 28: ...ll Hitch K958 2 Lunette Eye Hitch K965 1 Cable Rack K887 1 ETHER START KIT Provides maximum cold weather starting assistance for frequent starting below 4 C 25 F Required Ether tank is not provided wi...

Страница 29: ...eriodic Checks section of the Engine Operator s Manual for the recommended maintenance schedule of the following a Engine Oil and Filter b Air Cleaner c Fuel Filter and Delivery System d Alternator Be...

Страница 30: ...e engine BATTERY HANDLING GASES FROM BATTERY can explode Keep sparks flame and cigarettes away from battery To prevent EXPLOSION when INSTALLING A NEW BATTERY disconnect negative cable from old batter...

Страница 31: ...ted areas CLEANING Blow out the generator and controls periodically with low pressure air do this at least once a week in particularly dirty areas BRUSH REMOVAL AND REPLACEMENT It is normal for the br...

Страница 32: ...not understand or are unable to perform the Recommended Course of Action safely contact your local Lincoln Authorized Field Service Facility HOW TO USE TROUBLESHOOTING GUIDE Service and Repair should...

Страница 33: ...arter Contact authorized local Engine Service Shop 1 Out of fuel 2 Fuel shut off valve is in the off position make sure the valve lever is in a vertical direction Engine shut down solenoid not pulling...

Страница 34: ...circuit 4 Loose fan belt may need tightening 1 Idler switch in HIGH idle position make sure switch is set to AUTO 2 External load on welder or auxiliary power 3 Mechanical problem in idler solenoid li...

Страница 35: ...position be sure switch is in WELDING TERMINALS ALWAYS ON position 2 Faulty Weld Control PCB Pull Coil Battery PCB or Chopper PCB 1 Open circuit breakers 2 Faulty connections to auxiliary receptacles...

Страница 36: ...1 218 S5 214 MODE SELECTOR SWITCH 222 41 42 10A CB6 NEG NEG STATOR WELD WINDINGS W1 W6 W2 W3 W4 W5 W6 W6 W1 W1 W4 W5 W4 W5 W3 W3 W2 W2 RECTIFIER BRIDGE NEG NEG POS POS POS POS B8 B7 B7 B8 B3 B2 B1 B4...

Страница 37: ...Vantage 575 F 2 DIAGRAMS F 2 CONNECTION DIAGRAM...

Страница 38: ...N ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLT...

Страница 39: ...F 4 DIAGRAMS F 4 Vantage 575 CONNECTION DIAGRAM...

Страница 40: ...Vantage 575 F 5 DIAGRAMS F 5 CONNECTION DIAGRAM...

Страница 41: ...REASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLTS WIRE FE...

Страница 42: ...Vantage 575 F 7 DIAGRAMS F 7 CONNECTION DIAGRAM...

Страница 43: ...Vantage 575 F 8 DIAGRAMS F 8 CONNECTION DIAGRAM...

Страница 44: ...UTION ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE AC WIRE FEEDER VOLTAGE WHICH CAN DAMAGE THE CONTROL CIR...

Страница 45: ...Vantage 575 F 10 DIAGRAMS F 10 CONNECTION DIAGRAM...

Страница 46: ...Vantage 575 F 11 DIAGRAMS F 11 CONNECTION DIAGRAM...

Страница 47: ...Vantage 575 F 12 DIAGRAMS F 12 CONNECTION DIAGRAM...

Страница 48: ...Vantage 575 F 13 DIAGRAMS F 13 CONNECTION DIAGRAM...

Страница 49: ...24 56 9 50 15 1273 8 5 86 148 8 46 35 1177 3 BOTTOM VIEW OF WELDER BASE N A CENTER OF GRAVITY WITH OIL IN ENGINE EMPTY FUEL TANK AND COOLANT IN RADIATOR N A M18962 3 A 0 3 6 53 165 9 24 97 634 2 NOTE...

Страница 50: ...NOTES Vantage 575...

Страница 51: ...NOTES Vantage 575...

Страница 52: ...ot touch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa mojada Aislese del tra...

Страница 53: ...f r gute Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de alim...

Страница 54: ...s Leader in Welding and Cutting Products Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 USA Tel 216 481 8100 Fax 216 486 1751 Web Site www lincolnelectric...