6. OIL PRESSURE GAUGE 

The gauge displays the engine oil pressure when the engine is
running.

7. ENGINE PROTECTION

The yellow engine protection light remains off with proper oil
pressure and under normal operating temperatures. If the light
turns on, the engine protection system will stop the engine. Check
for proper oil level and add oil if necessary. Check for loose or
disconnected leads at the oil pressure sender located on the
engine. The light will remain on when the engine has been shut
down due to low oil pressure or over-temperature condition.

8. BATTERY CHARGING LIGHT

The yellow engine alternator light is off when battery charging
system is functioning normally. If light turns on, the engine
protection system will shut down the engine. Check the Engine
cooling blower belt. Also the alternator or the voltage regulator
may not be operating correctly. The light may also come on due
to a faulty flashing circuit. The light will remain on when the
engine is stopped and the run/stop switch is in the run position.

WELDING CONTROLS (Items 9 through 17)

9. OUTPUT CONTROL: 

The OUTPUT dial is used to preset the

output voltage or current as displayed on the digital meters for the
four welding modes. When in the CC-STICK, DOWNHILL PIPE or
CV-WIRE modes and when a remote control is connected to the
6-Pin or 14-Pin Connector, the auto-sensing circuit automatically
switches the OUTPUT CONTROL from control at the welder to
the remote control. In the CV-WIRE mode, when the wire feeder
control cable is connected to the 14-pin connector the auto-
sensing circuit automatically makes OUTPUT CONTROL inactive
and the wire feeder voltage control active.

When in the TOUCH START TIG mode and when a Amptrol is
connected to the 6-pin Connector, the OUTPUT dial is used to set
the maximum current range of the CURRENT CONTROL of the
Amptrol.

10. DIGITAL OUTPUT METERS: 

The digital meters allow the output voltage (CV-WIRE mode) or
current (CC-STICK, DOWNHILL PIPE and TIG modes) to be set
prior to welding using the OUTPUT control knob. During welding,
the meters display the actual output voltage (VOLTS) and current
(AMPS). A memory feature holds the display of both meters on
the seven seconds after welding is stopped. This allows the
operator to read the actual current and voltage just prior to when
welding was ceased. While the display is being held the left-most
decimal point in each display will be flashing. The accuracy of the
meters is ± 3%.

11. WELD MODE SELECTOR SWITCH:

(Provides four selectable welding modes)

CV-WIRE

DOWNHILL PIPE

CC-STICK

TOUCH START TIG

12. ARC CONTROL:

The ARC CONTROL WIRE/STICK knob is active in the WIRE
and STICK modes, and has different functions in these modes.
This control is not active in the TIG mode.

CC-STICK mode: In this mode, the ARC CONTROL knob sets the
short circuit current (arc-force) during stick welding. Increasing
the number from -10(Soft) to +10 (Crisp) increases the short
circuit current and prevents sticking of the electrode to the plate
while welding. This can also increase spatter. It is recommended
that the ARC CONTROL be set to the minimum number without
electrode sticking. Start with a setting at 0.

DOWNHILL PIPE mode: In this mode, the ARC CONTROL knob
sets the short circuit current (arc-force) during stick welding to
adjust for a soft or a more forceful digging arc (Crisp). Increasing
the number from -10 (Soft) to +10 (Crisp) increases the short
circuit current which results in a more forceful digging arc.
Typically a forceful digging arc is preferred for root and hot
passes. A softer arc is preferred for fill and cap passes where
weld puddle control and deposition (“stacking” of iron) are key to
fast travel speeds. It is recommended that the ARC CONTROL
be set initially at 0.

CV-WIRE mode: In this mode, turning the ARC CONTROL knob
from -10(soft) to +10(crisp) changes the arc from soft and
washed-in to crisp and narrow. It acts as an inductance/pinch
control. The proper setting depends on the procedure and
operator preference. Start with a setting of 0.

13. WELDING TERMINALS SWITCH

In the WELD TERMINALS ON position, the output is electrically
hot all the time. In the REMOTELY CONTROLLED position, the
output is controlled by a wire feeder or amptrol device, and is
electrically off until a remote switch is depressed.

B-3

OPERATION

B-3

Vantage 500 DEUTZ

Содержание Vantage 500 DEUTZ

Страница 1: ...MENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT Most importantly think before you act and be careful OPERATOR S MANUAL Copyright 2004 Lincoln Global Inc World s Leader in Welding and Cutting Products Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 USA Tel 216 481 8100 Fax 216 486 1751 Web Site www lincolnelectric com IM80...

Страница 2: ...tting ANSI Standard Z49 1 from the American Welding Society PO Box 351040 Miami Florida 33135 or CSA Standard W117 2 1974 or WTIA Welding Technology Institute of Australia PO Box 6165 Silverwater NSW 2128 A free copy of Arc Welding Safety booklet E205 is available from the Lincoln Electrical Company 22801 St Clair Avenue Cleveland Ohio 44117 1199 BE SURE THAT ALL INSTALLATION OPERATION MAINTENANCE...

Страница 3: ...e dangerous 5 a Welding may produce fumes and gases hazardous to health Avoid breathing these fumes and gases When welding keep your head out of the fume Use enough ventilation and or exhaust at the arc to keep fumes and gases away from the breathing zone When welding with electrodes which require special ventilation such as stainless or hard facing see instructions on container or MSDS or on lead...

Страница 4: ...explode 6 f Sparks and spatter are thrown from the welding arc Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap over your hair Wear ear plugs when welding out of position or in confined places Always wear safety glasses with side shields when in a welding area 6 g Connect the work cable to the work as close to the welding area as possible ...

Страница 5: ...s et non inflammables 4 Des gouttes de laitier en fusion sont émises de l arc de soudage Se protéger avec des vêtements de protection libres de l huile tels que les gants en cuir chemise épaisse pantalons sans revers et chaussures montantes 5 Toujours porter des lunettes de sécurité dans la zone de soudage Utiliser des lunettes avec écrans lateraux dans les zones où l on pique le laitier 6 Eloigne...

Страница 6: ...nformation below for future reference This information can be found on your machine nameplate Product _______________________________________________________________________________ Model Number _________________________________________________________________________ Code Number or Date Code_______________________________________________________________ Serial Number______________________________...

Страница 7: ...Lincoln Electric Wire Feeders A 8 A 9 Operation Section B Safety Instructions B 1 General Description B 1 Recommended Applications B 1 Controls and Settings B 2 Engine Controls B 2 Welder Controls B 3 Auxiliary Power Controls B 4 Engine Operation B 4 Starting The Engine B 4 Stopping the Engine B 4 Typical Fuel Consumption B 5 Welding Operation B 5 Duty Cycle B 5 Stick Welding Mode B 5 CC Stick Mod...

Страница 8: ...ter Separator Assembly D 2 Water Separator D 2 Secondary Fuel Filter D 2 Cooling System D 3 Cooling Blower Belt D 3 Battery Handling D 3 Charging the Battery D 4 Nameplate Warning Decal Maintenance D 4 Welder Generator Maintenance D 4 Engine Maintenance Components D 4 Troubleshooting Section E Wiring Connection Diagrams and Dimension Print Section F Parts Lists P 472 Series vii vii Vantage 500 DEU...

Страница 9: ...0 Volts 60 550 Amps DC multi purpose 36 volts 50 575 Amps DC multi purpose 35 volts PHYSICAL DIMENSIONS Height 2 Width Depth Weight 42 0 in 31 5 in 63 1 in 1615 lbs 1066 8 mm 800 1mm 1603mm 733kg Approx 1 Output rating in watts is equivalent to volt amperes at unity power factor Output voltage is within 10 at all loads up to rated capacity When welding available auxiliary power will be reduced 2 T...

Страница 10: ...bustible surface directly under stationary or fixed electrical equipment that surface should be covered with a steel plate at least 06 1 6mm thick which should extend not less than 5 90 150mm beyond the equipment on all sides STORING 1 Store the machine in a cool dry place when it is not in use Protect it from dust and dirt Keep it where it can t be accidentally damaged from construction activitie...

Страница 11: ... welder voltage rating 2 volts for every 10 C 21 F above 40 C 104 F TOWING The recommended trailer for use with this equipment for road in plant and yard towing by a vehicle 1 is Lincoln s K953 1 If the user adapts a non Lincoln trailer he must assume responsibility that the method of attachment and usage does not result in a safety hazard nor damage the welding equipment Some of the factors to be...

Страница 12: ...st diesel powered equipment needs only to be run at a reasonably heavy load within the rating of the welder for some period of time during the engine s early life However if the welder is subjected to extensive light loading occasional moderate to heavy loading of the engine may sometimes be necessary Caution must be observed in correctly loading a diesel generator unit 1 Connect the welder output...

Страница 13: ... be checked periodically and tightened if necessary Listed in Table A 1 are copper cable sizes recommended for the rated current and duty cycle Lengths stipulated are the distance from the welder to work and back to the welder again Cable sizes are increased for greater lengths primarily for the purpose of minimizing cable voltage drop Table A 1 Combined Length of Electrode and Work Cables MACHINE...

Страница 14: ...ible current of 50 A per output to two separate 120 VAC branch circuits The output voltage is within 10 at all loads up to rated capacity The Vantage has two 20 Amp 120VAC 5 20R GFCI duplex receptacles and one 50 Amp 120 240 VAC 14 50R receptacle The 120 240 VAC receptacle can be split for single phase 120 VAC operation The auxiliary power receptacles should only be used with three wire grounded t...

Страница 15: ...or cable of the desired length The 50 amp 120 240 VAC plug is available in the optional K802R plug kit 4 Plug this cable into the 50 Amp 120 240 Volt receptacle on the Vantage case front Figure A 2 Connection of the Vantage to Premises Wiring 240 Volt 60 Hz 3 Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION...

Страница 16: ...inal of the welder and work cable to the terminal of the welder Across The Arc Model Attach the single lead from the front of the LN 15 to work using the spring clip at the end of the lead This is a control lead to supply current to the wire feeder motor it does not carry welding current Control Cable Model Connect Control Cable between Engine Welder and Feeder Set the MODE switch to the CV WIRE p...

Страница 17: ...f you are using an LN 25 with an internal contactor the electrode is not energized until the gun trigger is closed If you are using an LN 25 without an internal contactor the electrode will be energized when the Vantage is started When the gun trigger is closed the current sensing circuit will cause the wire to begin to feed and the welding process is started CONNECTION OF AN NA 3 AUTOMATIC WELDIN...

Страница 18: ...ONAL SAFETY PRECAUTIONS Always operate the welder with the hinged door closed and the side panels in place as these provide maximum protection from moving parts and insure proper cooling air flow GENERAL DESCRIPTION The Vantage is a diesel engine driven welding power source The machine uses a brush type alternating current generator for DC multi purpose welding and for 120 240 VAC auxiliary standb...

Страница 19: ...use damage to the ring gear and or starter motor 3 HOUR METER The hour meter displays the total time that the engine has been running This meter is a useful indicator for scheduling preventive maintenance 4 FUEL LEVEL GAUGE Displays the level of diesel fuel in the fuel tank The operator must watch the fuel level closely to prevent running out of fuel and possibly having to bleed the system 5 ENGIN...

Страница 20: ...e meters display the actual output voltage VOLTS and current AMPS A memory feature holds the display of both meters on the seven seconds after welding is stopped This allows the operator to read the actual current and voltage just prior to when welding was ceased While the display is being held the left most decimal point in each display will be flashing The accuracy of the meters is 3 11 WELD MOD...

Страница 21: ...d and the reason for tripping the GFCI should be determined If the device is found to be damaged or defective it should be repaired or replaced before any further use The GFCI should be checked for proper operation prior to each use by pressing the test button The GFCI can be reset by pushing the reset button Refer to the AUXILIARY POWER RECEPTACLES section in the installation chapter for further ...

Страница 22: ...START TIG MODE The Vantage can be used in a wide variety of DC TIG welding applications The TOUCH START TIG setting of the MODE switch is for DC TIG Tungsten Inert Gas welding To initiate a weld the OUTPUT CONTROL knob is first set to the desired current and the tungsten is touched to the work During the time the tungsten is touching the work there is very little voltage or current and in general ...

Страница 23: ... 1 When used with argon gas The current ranges shown must be reduced when using argon helium or pure helium shielding gases 2 Tungsten electrodes are classified as follows by the American Welding Society AWS Pure EWP 1 Thoriated EWTh 1 2 Thoriated EWTh 2 Though not yet recognized by the AWS Ceriated Tungsten is now widely accepted as a substitute for 2 Thoriated Tungsten in AC and DC applications ...

Страница 24: ...ontrol switch to the desired operating mode Full power is available regardless of the welding control settings if no welding current is being drawn The auxiliary power of the Vantage consists of two 20 Amp 120VAC 5 20R GFCI duplex receptacles and one 50 Amp 120 240 VAC 14 50R receptacle The 120 240VAC receptacle can be split for single phase 120 VAC operation The auxiliary power capacity is 12 000...

Страница 25: ...50 250 300 250 200 91 183 69 137 76 91 76 61 Maximum Allowable Cord Length in ft m for Conductor Size Conductor size is based on maximum 2 0 voltage drop 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG TABLE B 4 Vantage Simultaneous Welding and Power Loads Welding Output Permissible Power Watts Permissible Auxiliary at NEMA Voltage Unity Power Factor Current in Amperes V 04I 20 120VAC 10 240 VAC 10 0 250A ...

Страница 26: ...th optional fender and light package For highway use consult applicable federal state and local laws regarding possible additional requirements There is a choice of 2 hitches a fender a light package Order K953 1 Trailer K958 1 Ball Hitch K958 2 Lunette Eye Hitch K959 1 Fender Light Kit K965 1 Cable Rack K887 1 ETHER START KIT Provides maximum cold weather starting assistance for frequent starting...

Страница 27: ...tion of the Engine Operator s Manual for the recommended maintenance schedule of the following a Engine Oil and Filter b Air Cleaner c Fuel Filter and Delivery System d Cooling Blower Belt e Battery f Cooling System Refer to Table D 1 at the end of this section for various engine maintenance components AIR FILTER EXCESSIVE AIR FILTER RESTRICTION WILL RESULT IN REDUCED ENGINE LIFE The air filter el...

Страница 28: ...r of the upper cavity 7 Re insert the large white volume plug into the upper cavity 8 Place the O ring onto the angled seal surface of the filter header and re install the plastic cap Make sure its flange rests on the O ring 9 Screw on the cap ring and tighten hand tight 10 Remember to open the fuel shutoff valve Lever in line with the hose before starting the engine WATER SEPARATOR ELEMENT The wa...

Страница 29: ...SION when INSTALLING A NEW BATTERY disconnect negative cable from old battery first and connect to new battery last CONNECTING A BATTERY CHARGER Remove battery from welder by disconnecting negative cable first then positive cable and battery clamp When reinstalling connect negative cable last Keep well ventilated USING A BOOSTER connect positive lead to battery first then connect negative lead to ...

Страница 30: ... legibility Replace those which are no longer clear Refer to the parts list for the replacement item number WELDER GENERATOR MAINTENANCE STORAGE Store the Vantage in clean dry protected areas CLEANING Blow out the generator and controls periodically with low pressure air do this at least once a week in particularly dirty areas BRUSH REMOVAL AND REPLACEMENT It is normal for the brushes and slip rin...

Страница 31: ... understand or are unable to perform the Recommended Course of Action safely contact your local Lincoln Authorized Field Service Facility HOW TO USE TROUBLESHOOTING GUIDE Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your facto...

Страница 32: ...ngine protection light lit 1 Low oil pressure engine protection light lit Check oil level Consult engine service dealer 2 High oil temperature engine protection light lit 3 Faulty oil pressure switch 4 Faulty oil temperature switch Contact authorized local Engine Service Shop 5 Low output of battery charging alternator battery charging light lit 1 High oil temperature 1 Dirty fuel or air filters m...

Страница 33: ...INALS switch in wrong position be sure to place switch in WELDING TERMINALS ALWAYS ON position 2 Faulty Weld Control PCB Pull Coil Battery PCB or Chopper PCB 1 Open breakers 2 Faulty receptacle 3 Faulty auxiliary circuit wiring 4 GFCI tripped RECOMMENDED COURSE OF ACTION If all recommended possible areas of misadjustment have been checked and the problem persists Contact your local Lincoln Authori...

Страница 34: ... SIDE CHOPPER PCB5 NEG POS NEG POS LEFT SIDE CHOPPER PCB6 B6 B5 B4 B1 B2 B3 13 14 B6 B5 B4 B1 B2 B3 1 8 9 1 6 J7 J3 1 9 16 8 1 6 7 12 1 16 9 8 6 10 J4 J5 6 10 CONTROL MODE SEL CHOPPER POWER PWM THERMAL 25A 23A 13 14 77 76 75 2 4 75A 76A 77A 271 200 500 239 CV CC TIG PIPE 405B R4 232B 232C 206C 208C B8 B7 B8 B7 INSULATED NEUTRAL STUD ON BOTTOM RIGHT OF CONTROL BOX GROUND STUD ON OUTPUT PANEL GND J ...

Страница 35: ...Vantage 500 DEUTZ F 2 DIAGRAMS F 2 CONNECTION DIAGRAM ...

Страница 36: ...UTION ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLTS WIRE FEEDER CONTROL CIRCUITS MAY BE THE ENGINE WELDER OPERATING MANUAL N A WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPILICATIONS SEE OPERA...

Страница 37: ...F 4 DIAGRAMS F 4 Vantage 500 DEUTZ CONNECTION DIAGRAM ...

Страница 38: ...Vantage 500 DEUTZ F 5 DIAGRAMS F 5 CONNECTION DIAGRAM ...

Страница 39: ... INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE IF THIS VOLTAGE GOES OVER 140 VOLTS WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED THE ENGINE GOVERNOR SETTING IS PRE SET AT THE FACTORY DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN N B USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POL...

Страница 40: ...Vantage 500 DEUTZ F 7 DIAGRAMS F 7 CONNECTION DIAGRAM ...

Страница 41: ...Vantage 500 DEUTZ F 8 DIAGRAMS F 8 CONNECTION DIAGRAM ...

Страница 42: ...T CAUTION ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE AC WIRE FEEDER VOLTAGE WHICH CAN DAMAGE THE CONTROL CIRCUIT THE ENGINE GOVERNOR SETTING IS PRE SET AT THE FACTORY DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN THE ENGINE WELDER OPERATING MANUAL N A WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE...

Страница 43: ...Vantage 500 DEUTZ F 10 DIAGRAMS F 10 CONNECTION DIAGRAM ...

Страница 44: ...Vantage 500 DEUTZ F 11 DIAGRAMS F 11 CONNECTION DIAGRAM ...

Страница 45: ...Vantage 500 DEUTZ F 12 DIAGRAMS F 12 CONNECTION DIAGRAM ...

Страница 46: ...Vantage 500 DEUTZ F 13 DIAGRAMS F 13 CONNECTION DIAGRAM ...

Страница 47: ...31 50 45 67 10 22 BOTTOM VIEW OF WELDER BA CENTER OF GRAVITY WITH OIL IN ENGINE AND FULL FUEL TANK NOTE This diagram is for reference only It may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to the Service Department for a replacement Give the equipmen...

Страница 48: ...NOTES VANTAGE 500 DEUTZ ...

Страница 49: ... not touch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa mojada Aislese del trabajo y de la tierra Ne laissez ni la peau ni des vêtements mouillés entrer en contact avec des pièces sous tension Isolez vous du travail et de la terre Berühren Sie keine stromführenden Teile oder ...

Страница 50: ...n Sie für gute Be und Entlüftung des Arbeitsplatzes Mantenha seu rosto da fumaça Use ventilação e exhaustão para remover fumo da zona respiratória Turn power off before servicing Desconectar el cable de alimentación de poder de la máquina antes de iniciar cualquier servicio Débranchez le courant avant l entretien Strom vor Wartungsarbeiten abschalten Netzstrom völlig öffnen Maschine anhalten Não o...

Страница 51: ...d s Leader in Welding and Cutting Products Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 USA Tel 216 481 8100 Fax 216 486 1751 Web Site www lincolnelectric com ...

Отзывы: