A-2
INSTALLATION
SAE-300
®
HE
A-2
GENERAL DESCRIPTION
TheSAE-300
®
HEisaheavyduty,enginedriven,DC
arc welding power source, capable of providing con-
stantcurrentoutputforstickweldingorDCTIGweld-
ing. This welder is wound with all copper coils, rated
at 300 amps/32 Volts, and provides other Classic
®
featuressuchasimproveddoorlatchesandstainless
hinges.WiththeadditionoftheoptionalK3964-1Wire
Feed Module™, the SAE-300
®
HE will provide con-
stant voltage output for running the LN-7, LN-23P, or
LN-25wirefeeders.(TheWireFeedModuleisfactory
installed on the K3201-2). The optional K924-5
Remote Control Kit, provides a remote control rheo-
stat for remote fine current and open circuit voltage
adjustment.SeeSectionCfordescription.
The SAE-300
®
HE has an Electronic Engine
Protection System. In the event of sudden low oil
pressure or high coolant temperature, the engine
immediately shuts down. The SAE-300
®
HE has a
current range of 40-350 DC amps with output ratings
asfollows:
These units are also capable of providing 3 KVA of
120/240voltsof60cycleACauxiliarypower.
TheSAE-300
®
HEusestheKubotaD1503-Mindustri-
alwater-cooleddieselengine.
DESIGN FEATURES
Control Panel
The welder controls consist of a Reactor and a “Fine
Current Adjustment” rheostat located on the upper
control panel at the exciter end of the machine. The
lower control panel welder is equipped with a “Start”
button, an “Ignition” switch, an “Idler” control switch,
anda“GlowPlug”buttonforeasiercoldweatherstart-
ing.
Thelowercontrolpanelalsocontainsanenginetem-
perature gauge, a battery charging fault indicator, an
oil pressure gauge, a fuel / hour / LED indicator
gauge, temperature gauge, for auxiliary power con-
sistsofone20amp,120VAC(5-20R)duplexrecepta-
clewithGFCIprotectionandone15amp,240VAC(6-
15R)receptacle,protectedby2pole,15Ampbreak-
er.
All Copper Windings
-Forlonglifeanddependable
operation.
Engine Idler
-TheSAE-300
®
HEisequippedwithan
electronic automatic engine idler. It automatically
increasesanddecreasesenginespeedwhenstarting
andstoppingweldingorusingauxiliarypower.
A built-in time delay permits changing electrodes
beforetheengineslowstoitslowidlespeed.
The “Idler” control switch on the panel locks the idler
inhighidlepositionwhendesired.
Auxiliary Power
- 3.0 KVA of nominal 120/240V,
60Hz,AC.Outputvoltageismaintainedwithin±10%
at all loads up to rated capacity. (See Optional
FeaturesSectionCforPowerPlugKit.)
GFCI -
Protectsthe20amp,120Vduplexreceptacle.
See the
Maintenance Section
for detailed informa-
tionontestingandresettingoftheGFCI.
120 V DUPLEx RECEPTACLE AND GFCI
AGFCIprotectsthe120Vauxiliarypower
receptacle.
A GFCI (Ground Fault Circuit Interrupter) is a device to
protectagainstelectricshockshouldapieceofdefective
equipmentconnectedtoitdevelopagroundfault.Ifthis
situation should occur, the GFCI will trip, removing volt-
agefromtheoutputofthereceptacle.IfaGFCIistripped
see the MAINTENANCE section for detailed information
on testing and resetting it. A GFCI should be properly
testedatleastonceeverymonth.
The 120 V auxiliary power receptacle should only be
used with three wire grounded type plugs or approved
double insulated tools with two wire plugs. The current
ratingofanyplugusedwiththesystemmustbeatleast
equal to the current capacity of the associated recepta-
cle.
250A@30V
300A@32V
100%
60%
RATED OUTPUT
DUTY CYCLE