E-5
TROUBLESHOOTING
SAE-300
®
HE
E-5
ELECTRONIC IDLER TROUBLESHOOTING GUIDE
Ifforanyreasonyoudonotunderstandthetestproceduresorareunabletoperformthetests/repairssafely,contactyour
Local Lincoln Authorized Field Service Facility
fortechnicaltroubleshootingassistancebeforeyouproceed.
CAUTION
With Idler Control Switch in the AUTO Position, Engine Will Not Pick Up Speed When:
The Arc is Struck
Both
Auxiliary Load
1.Check Idler circuit wiring. Possible
Problems are wires from Current Sensing
Board reversed at idler switch or wires
connected incorrectly at Current Sensor
Molexplug.
2.Checkvoltageacrossidlercontrol
switch.
12V
0V
ReplaceCurrent
ContactKubota
SensingPCB
EngineRepair
Facility.
Checkforlooseordisconnected
wirerunningbetweenweld
selectorswitchandoutputstud.
1.Load too small. Try load
above100Watts.
2.Check for loose or discon-
nected wire running from
black lead out of exciter to
CB2circuitbreaker.