TROUBLESHOOTING & REPAIR
F-15
F-15
PRO-CUT 55
INPUT RECTIFIER TEST
(continued)
TEST PROCEDURE
1. Remove main input power to the machine.
2. Perform the
Input Filter Capacitor
Discharge Procedure
detailed earlier in
this section.
3. Locate the input rectifier (D1) and lead loca-
tions. See Figure F.2.
4. With the phillips head screw driver, remove
leads #207, 207A and #209 from the rectifi-
er.
5. Use the analog ohmmeter to perform the
tests detailed in
Table F.1.
See the Wiring
Diagram.
FIGURE F.2 – INPUT RECTIFIER AND LEADS
#207
#207A
#209 (+)
C
B
A
(-)