Lincoln Electric POWERTEC i350S Скачать руководство пользователя страница 3

English  

English 

Technical Specifications 

 

NAME 

INDEX 

POWERTEC

®

 i350S 

K14183-1 

POWERTEC

®

 i420S 

K14184-1 

POWERTEC

®

 i500S 

K14185-1 

INPUT 

 

Input Voltage U

1

 EMC 

Class 

Frequency 

i350S 

400V ± 15% 3-phase 

50/60Hz 

i420S 
i500S 

 

 

Input Power at Rated Cycle Input 

Amperes 

I

1max

 PF 

i350S 

15 kVA @ 50% Duty Cycle 

(40°C) 

21A 0,90 

i420S 

19 kVA @ 100% Duty Cycle 

(40°C) 

27A 0,92 

i500S 

23 kVA @ 60% Duty Cycle 

(40°C) 

34A 0,94 

 

 

Efficiency Idle 

Power 

 

i350S 

85% 35W 

i420S 

85% 35W 

i500S 

85% 35W 

RATED OUTPUT 

 

Open Circuit 

Voltage 

 

Duty Cycle 40°C 

(based on a 10 min. 

period) 

Output Current 

Output Voltage 

i350S 

U

0peak 

= 54Vdc 

 
U

0rms 

= 54Vdc 

 

GMAW 

50% 350A 

31,5Vdc 

60% 340A 

31,0Vdc 

100% 250A 26,5Vdc 

FCAW 

50% 350A 

31,5Vdc 

60% 340A 

31,0Vdc 

100% 250A 26,5Vdc 

SMAW 

30% 350A 

34,0Vdc 

60% 320A 

32,8Vdc 

100% 250A 30,0Vdc 

i420S 

U

0peak 

= 60Vdc 

 
U

0rms 

= 54Vdc 

 

GMAW 100% 

420A 

35,0Vdc 

FCAW 100% 

420A 

35,0Vdc 

SMAW 100% 

420A 

36,8Vdc 

i500S 

U

0peak 

= 60Vdc 

 
U

0rms 

= 54Vdc 

 

GMAW 

60% 500A 

39,0Vdc 

100% 420A 35,0Vdc 

FCAW 

60% 500A 

39,0Vdc 

100% 420A 35,0Vdc 

SMAW 

60% 480A 

39,2Vdc 

100% 420A 36,8Vdc 

WELDING CURRENT RANGE 

 GMAW 

FCAW 

SMAW 

i350S 

20A÷350A 20A÷350A  10A÷350A 

i420S 

20A÷420A 20A÷420A  10A÷420A 

i500S 

20A÷500A 20A÷500A  10A÷480A 

Содержание POWERTEC i350S

Страница 1: ...IM3103 11 2019 REV00 POWERTEC i350S i420S i500S OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu ...

Страница 2: ...table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 1 Electromagnetic Compatibility EMC 3 Safety 4 Intoduction 6 Installation and Operator Instructions 6 WEEE 10 Spare Parts 10 REACh 10 Authorized Service Shops Location 10 Electrical Sch...

Страница 3: ...Open Circuit Voltage Duty Cycle 40 C based on a 10 min period Output Current Output Voltage i350S U0peak 54Vdc U0rms 54Vdc GMAW 50 350A 31 5Vdc 60 340A 31 0Vdc 100 250A 26 5Vdc FCAW 50 350A 31 5Vdc 60 340A 31 0Vdc 100 250A 26 5Vdc SMAW 30 350A 34 0Vdc 60 320A 32 8Vdc 100 250A 30 0Vdc i420S U0peak 60Vdc U0rms 54Vdc GMAW 100 420A 35 0Vdc FCAW 100 420A 35 0Vdc SMAW 100 420A 36 8Vdc i500S U0peak 60Vdc...

Страница 4: ...se Type Time Delay or Circuit Breaker Type D Power Lead 400V i350S 25A 4 Conductor 2 5mm2 i420S 32A 4 Conductor 4 0 mm2 i500S 32A 4 Conductor 4 0 mm2 DIMENSION Weight Height Width Length i350S 68kg 932 mm 560 mm 925 mm i420S 78kg i500S 79kg Protection Rating Operating Humidity t 20 C Operating Temperature Storage Temperature IP23 90 from 10 ºC to 40 ºC from 25 ºC to 55 ºC ...

Страница 5: ...ing Input and output cables control cables and telephone cables that are in or adjacent to the work area and the machine Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immun...

Страница 6: ...MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in...

Страница 7: ...removed Do not allow the electrode electrode holder work clamp or any other electrically live part to touch a gas cylinder Gas cylinders must be located away from areas where they may be subjected to physical damage or the welding process including sparks and heat sources SAFETY MARK This equipment is suitable for supplying power for welding operations carried out in an environment with increased ...

Страница 8: ...ntrolled machinery which may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature higher than 40 C Duty cycle and Overheating The duty cycle of a welding machine is the percentage of time in a 10 minute cycle at which the welder can operate the machine at rated welding current Example 60 duty cycle...

Страница 9: ...Coupling Coolant outlet supplies cool coolant to the torch gun Figure 2 8 Supply Plug for gas heater kit see Accessories Suggested chapter 9 Power Lead 5m Connect the supply plug to the existing input cable that is rated for the machine as indicated in this manual and conforms to all applicable standards This connection shall be performed by a qualified person only 10 Gas Connector For connection ...

Страница 10: ...rce The COOL ARC 26 is supplied by welding power source using 10 PIN socket Figure 4 Machine and Circuit Protection Power Source is protected against overheating overload and accidental short circuits If the machine is overheated the thermal protection circuit will decrease the output current to 0 This information will be shown by wire feeder user interface Please refer to wire feeder user manual ...

Страница 11: ...cted from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purchasers may ask Linc...

Страница 12: ...ting First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communication in accordance with Article 33 1 of Regulation EC No 1907 2006 REACh Some parts inside this product contain Bisphenol A BPA EC 201 245 8 CAS 80 05 7 Cadmium EC 231 152 8 CAS 7440 43 9 Lead EC ...

Страница 13: ... PG CABLE PACK 5PIN G 70MM2 1 M K14198 PG 5M CABLE PACK 5PIN G 70MM2 5M K14198 PG 10M CABLE PACK 5PIN G 70MM2 10M K14198 PG 15M CABLE PACK 5PIN G 95MM2 15M K14198 PG 20M CABLE PACK 5PIN G 95MM2 20M K14198 PG 25M CABLE PACK 5PIN G 95MM2 25M K14198 PG 30M CABLE PACK 5PIN G 95MM2 30M K14199 PGW CABLE PACK 5PIN W 95MM2 1 M K14199 PGW 5M CABLE PACK 5PIN W 95MM2 5M K14199 PGW 10M CABLE PACK 5PIN W 95MM2...

Страница 14: ...English English 12 Connection configuration Figure 6 ...