CASE FRONT CONTROLS
(See Figure B.1)
1. (NO OPTIONAL) USER INTERFACE
2. STATUS LED -
(See Troubleshooting Section for
operational functions)
3. THERMAL LED -
Indicates when machine has
thermal fault.
4. POWER SWITCH -
Controls power to the POWER
WAVE® S350CE.
5. WORK STUD
6. ELECTRODE STUD
7. WORK SENSE LEAD
8. ARCLINK RECEPTACLE
B-3
OPERATION
B-3
DESIGN FEATURES
Loaded with Standard Features
• Multiple process DC output range: 5 - 350 Amps
• 200 – 600 VAC, 1/3 phase, 50-60Hz input power
• New and Improved Line Voltage Compensation
holds the output constant over wide input voltage
fluctuations.
• Utilizes next generation microprocessor control,
based on the ArcLink® platform.
• State of the art power electronics technology yields
superior welding capability.
• Electronic over current protection
• Input over voltage protection.
• F.A.N. (fan as needed). Cooling fan only runs
when needed.
• Thermostatically protected for safety and reliability.
• Recessed connection panel for protection against
accidental impact.
• Ethernet connectivity via ODVA compliant RJ-45
connector.
• Panel mounted Status and Thermal LED indicators
facilitate quick and easy troubleshooting.
• Potted PC boards for enhanced ruggedness/relia-
bility.
• Enclosure reinforced with heavy duty aluminum
extrusions for mechanical toughness
• Waveform Control Technology™ for good weld
appearance and low spatter, even when welding
nickel alloys.
• Compatible with stackable STT® and Water Cooled
Modules upgrades.
• Devicenet relay.
POWER WAVE® S350CE
1
2
3
4
6
7
8
5
FIGURE B.1