Lincoln Electric POWER FEED 10S Скачать руководство пользователя страница 4

FOR ELECTRICALLY
powered equipment.

8.a. Turn off input power using the disconnect

switch at the fuse box before working on
the equipment.

8.b. Install equipment in accordance with the U.S. National

Electrical Code, all local codes and the manufacturer’s
recommendations.

8.c. Ground the equipment in accordance with the U.S. National

Electrical Code and the manufacturer’s recommendations.

CYLINDER may explode
if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely

chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

• Away from areas where they may be struck or subjected to

physical damage.

• A safe distance from arc welding or cutting operations and

any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other

electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet

when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand

tight except when the cylinder is in use or connected for
use.

7.g. Read and follow the instructions on compressed gas

cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.

iii

SAFETY

iii

Mar ‘95

WELDING SPARKS can
cause fire or explosion.

6.a. Remove fire hazards from the welding area.

If this is not possible, cover them to prevent

the welding sparks from starting a fire.
Remember that welding sparks and hot

materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site,

special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.

6.c. When not welding, make certain no part of the electrode

circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the

proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even though they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).

6.e. Vent hollow castings or containers before heating, cutting or

welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil

free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.

6.g. Connect the work cable to the work as close to the welding

area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.

6.h. Also see item 1.c.

Содержание POWER FEED 10S

Страница 1: ...nds on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overall safety can be increased by proper installation and thought ful operation on your par...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...cal earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for coo...

Страница 4: ...vent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic...

Страница 5: ...appropri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paiss...

Страница 6: ...below for future reference This information can be found on your machine nameplate Product _________________________________________________________________________________ Model Number ______________...

Страница 7: ...onversion Kits A 6 ________________________________________________________________________________ Accessory Section C Motor Conversion Kit For 142 1 NA Style Wire Drives C 1 ________________________...

Страница 8: ...any axes of rotation for ease of fixturing and locating RECOMMENDED PROCESSES The Power Feed 10S series of wire drives are best suited for submerged arc welding PROCESS LIMITATIONS MIG welding Robotic...

Страница 9: ...ightener 32Vdc permanent magnet high torque motor Conversion kit included to change speed range Voltage sense leads included for precision welding performance LOCATION OF COMPONENTS CENTERLINE OF WIRE...

Страница 10: ...lbs 15 9kg 80 0lbs 36 3kg 10 0lbs 4 5kg Input Amperes 7 Amps max OPERATING TEMPERATURE RANGE 4 F to 104 F 20 C to 40 C STORAGE TEMPERATURE RANGE 40 F to 185 F 40 C to 85 C WELDING PROCESSES Spec Type...

Страница 11: ...e working on the equip ment Do not touch electrically hot parts NON STANDARD SAFETY INFORMATION The PF 10S series of wire drives may be at weld ing voltage potential when the output of the power sourc...

Страница 12: ...oles or the two 0 562 through holes See mounting hole locations Figure A 2 FIGURE A 1 FIGURE A 2 POWER WAVE AC DC 1000 K2344 1 K1543 xx ARCLINK CONTROL CABLE ELECTRODE SENSE LEAD A R C 1 K1785 xx 14 1...

Страница 13: ...lling the quick connect terminals apart 6 Reverse the motor leads and reconnect the quick connect terminals see Wiring Diagram 7 Carefully replace the wire harness back into the Connection Box and pla...

Страница 14: ...le A 1 TABLE A 1 Output Cable Guidelines When using inverter type power sources like the Power Wave use the largest welding electrode and work cables that are practical When pulsing the pulse current...

Страница 15: ...wire feed speed the same for all the arcs When these parameters are identical the pulsing fre quency will be the same helping to stabilize the arcs If the voltage sensing is enabled but the sense lea...

Страница 16: ...the shaft Replace plain washer tighten the hex nut and remove the adapter plate and motor assembly mounting screws from the gear 6 Support the pinion properly and with the proper size punch drive the...

Страница 17: ...Conversion Kit to assemble correctly If both assemblies are not con figured for the same gear ratio this must be done before continuing See Gear Ratio Conversion Kit instructions 4 Cover the teeth of...

Страница 18: ...IFICATION All calibration is factory set on the Power Feed 10S To verify the wire feed speed Press the INCH DOWN switch and adjust the wire feed speed to 100 in min 2 54m min Measure the actual wire f...

Страница 19: ...LE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause generall...

Страница 20: ...on 2 Incorrect drives rolls and or guide tubes or incorrect pres sure setting Ensure drive rolls and or guide tubes are stamped with wire diameter being used Replace if necessary Check for proper pres...

Страница 21: ...L1 F1 6A NOTES N A CAVITY NUMBERING SEQUENCE AS VIEWED FROM COMPONENT SIDE OF PC BOARD N B CAVITY NUMBERING SEQUENCE AS VIEWED FROM LEAD SIDE OF CONNECTOR ELECTRICAL SYMBOLS PER E1537 LEAD COLOR CODIN...

Страница 22: ...6 16 2 43 5 19 3 50 21 2 82 CENTERLINE OF WIRE CENTERLINE OF WIRE 2 60 ISO VIEW REF ONLY 2 50 50 50 O 562 2 HOLES CENTERLINE OF WIRE CENTERLINE OF MOUNTING BRACKET 4 26 6 16 11 29 3 8 16 TAPPED HOLES...

Страница 23: ...NOTES POWER FEED 10S...

Страница 24: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 25: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 26: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: