![Lincoln Electric POWER-ARC 4000 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/lincoln-electric/power-arc-4000/power-arc-4000_service-manual_1918469083.webp)
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
F-35
TROUBLESHOOTING & REPAIR
F-35
POWER-ARC 4000
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics.
OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
No Load RPM
Load RPM
Maximum Speed
3725
3650
Minimum Speed
3675
3400
WELDER/GENERATOR OUTPUT
1
Ou
t
put Control
Field Volts
Field Amps
Open Circuit
Load Volts
Load Amps
Volts
Maximum
43 - 49
4.8 - 5.8
60 - 63
12 - 25
120 - 125
Minimum
–
–
55 - 60
14 - 27
75 - 85
AUXILIARY POWER RECEPTACLE OUTPUT
1
230 Volt Receptacle
115 Volt Receptacle
2
Output
Open Circuit
Load Volts
Load Amps
Open Circuit
Load Volts
Load Amps
Control
Volts
Volts
Maximum
255 - 267
215 - 230
18 - 20
127 - 133
112 - 120
18 - 20
1
Current Control Dial set at MAXIMUM or GENERATOR.
2
Output values of each receptacle can vary within the range shown