B-8
OPERATION
MAX
SA™
10 CONTROLLER
The Setup Menu provides access for configuring user preferences, which are generally only set at installation. The user preferences
are grouped as shown in the following table.
SETUP MENU FEATURES
ACCESSING THE SETUP MENU
1. ACCESS
To access the Setup Menu, Press the Left Button and Right Button
simultaneously. The Setup Menu Indicator will light and the lower
display will read as shown below.
Note: The Setup Menu cannot be accessed during welding, or if a
fault is displayed. To resume welding, exit the Setup Menu.
2. PREFERENCE SELECTION
Scroll through the Preference list by rotating the Control Knob.
Press the Right Button to edit the selected preference.
3. PREFERENCE CHANGE
Scroll through the preference options by rotating the Control
Knob. Change the preference setting by pressing the Right Button.
To cancel, press the Left Button.
4. EXIT
To exit the Setup Menu, press both buttons simultaneously or
select P.0 and press the Left Button. Sixty seconds of inactivity
will automatically exit the Setup Menu.
Note:
If a product is missing any of the preference options listed
below, a software update may be needed from
www.powerwavesoftware.com.
FIGURE B.7 - SETUP MENU
P
.
0
Exit
User
Prefs
Setup Menu
Indicator
Mode Select
Panel (MSP)
Left Button
Control Knob
Right Button
PARAMETER
P.1
through
P.99
P.101
through
P.199
P.501
through
P.599
DEFINITION
Unsecured Parameters (always adjustable)
Diagnostic Parameters (always read only)
Secured Parameters (only accessible with Weld Manager)