Lincoln Electric Magnum PRO 250 LX Скачать руководство пользователя страница 3

SECTION A:

WARNINGS

  

CALIFORNIA PROPOSITION 65 WARNINGS

WARNING: 

Breathing diesel engine exhaust

exposes you to chemicals known to the State
of California to cause cancer and birth defects,

or other reproductive harm.

• Always start and operate the engine in a 

well-ventilated area.

• If in an exposed area, vent the exhaust to the outside.
• Do not modify or tamper with the exhaust system. 
• Do not idle the engine except as necessary.

For more information go to 

www.P65 warnings.ca.gov/diesel

WARNING: This product, when used for welding or
cutting, produces fumes or gases which contain
chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California
Health & Safety Code § 25249.5 

et seq.)

WARNING: Cancer and Reproductive Harm
www.P65warnings.ca.gov

ARC WELDING CAN BE HAZARDOUS. PROTECT
YOURSELF AND OTHERS FROM POSSIBLE SERIOUS
INJURY OR DEATH. KEEP CHILDREN AWAY. 
PACEMAKER WEARERS SHOULD CONSULT WITH
THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For
additional safety information, it is strongly recommended 
that you purchase a copy of “Safety in Welding & Cutting - 
ANSI Standard Z49.1” from the American Welding Society, 
P.O. Box 351040, Miami, Florida 33135 or CSA Standard 
W117.2-1974. A Free copy of “Arc Welding Safety” booklet 
E205 is available from the Lincoln Electric Company, 
22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION,
MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE POWERED

EQUIPMENT.

   1.a. Turn the engine off before troubleshooting

and maintenance work unless the
maintenance work requires it to be running.

   1.b. Operate engines in open, well-ventilated areas or vent the engine

exhaust fumes outdoors.

   1.c. Do not add the fuel near an open flame welding

arc or when the engine is running. Stop the
engine and allow it to cool before refueling to
prevent spilled fuel from vaporizing on contact

with hot engine parts and igniting. Do not spill fuel when filling
tank. If fuel is spilled, wipe it up and do not start engine until
fumes have been eliminated.

   1.d.  Keep all equipment safety guards, covers 

and devices in position and in good repair.
Keep hands, hair, clothing and tools away 
from V-belts, gears, fans and all other 
moving parts when starting, operating or
repairing equipment.

   1.e. In some cases it may be necessary to remove safety guards to

perform required maintenance. Remove guards only when
necessary and replace them when the maintenance requiring
their removal is complete. Always use the greatest care when
working near moving parts.

   1.f.  Do not put your hands near the engine fan. Do not attempt to

override the governor or idler by pushing on the throttle control
rods while the engine is running.

   1.g. To prevent accidentally starting gasoline engines while turning

the engine or welding generator during maintenance work,
disconnect the spark plug wires, distributor cap or  magneto wire
as appropriate.

   1.h. To avoid scalding, do not remove the radiator

pressure cap when the engine is 

hot.

ELECTRIC AND

MAGNETIC FIELDS MAY

BE DANGEROUS

   2.a. Electric current flowing through any conductor

causes localized Electric and Magnetic Fields (EMF). 
Welding current creates EMF fields around welding cables 
and welding machines

   2.b. EMF fields may interfere with some pacemakers, and 

welders having a pacemaker should consult their physician
before welding.

   2.c. Exposure to EMF fields in welding may have other health effects

which are now not known.

   2.d. All welders should use the following procedures in order to

minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure

them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work

cables. If the electrode cable is on your right side, the
work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as pos-

sible to the area being welded.

2.d.5. Do not work next to welding power source.

SAFETY

Safety 02 of 04 - 5/16/2018

Содержание Magnum PRO 250 LX

Страница 1: ...gister Authorized Service and Distributor Locator www lincolnelectric com locator IM10484 Issue Date Nov 16 18 Lincoln Global Inc All Rights Reserved K Number K3569 2 Magnum PRO 250 LX GT K3570 2 Magn...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...hot engine parts and igniting Do not spill fuel when filling tank If fuel is spilled wipe it up and do not start engine until fumes have been eliminated 1 d Keep all equipment safety guards covers and...

Страница 4: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with s...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...CTION 6 MAKING A WELD 7 MACHINE OPERATION SECTION 7 PROCEDURE SETTINGS 8 SETTING GAS FLOW RATE 9 OPTIONAL KITS AND ACCESSORIES 10 MAINTENANCE 10 ROUTINE MAINTENANCE 10 TROUBLESHOOTING 11 HOW TO USE TR...

Страница 7: ...aded to withstand the harsh conditions of being used in rugged environments NOTE Please turn off gas when not in use SPECIFICATIONS SUPPLIED wITH KP2745 364AT 3 64 Contact Tip KP2747 1A Aluminum Diffu...

Страница 8: ...l of the parts listed KP2745 364AT Contact Tip 3 64 1 2mm Included KP2747 1A Aluminum Gas Diffuser Installed KP2743 1 62RA Aluminum Gas Nozzle Installed 1 8 Recess 625 ID KP2518 2 U Groove Drive Roll...

Страница 9: ...l be in the 3 64 operating position Reverse roller for 030 or 035 inch 0 9 mm diameter wire 5 Gas nozzle directs gas flow around arc Pull off gas nozzle to see contact tip and gas diffuser Spool gun i...

Страница 10: ...e available and the best choice depends on the type of base metals and the desired characteristics of the weldment such as ductility and strength corrosion resistance sustained service temperature and...

Страница 11: ...between drive roll pressure idler roll 8 Push wire until wire end extends approximately 6 150 mm past end of gas diffuser Re engage idle roll pressure by pushing release lever down as shown above the...

Страница 12: ...rive Roll Orientation B Changing Drive Roll Orientation Note The drive roll and motor shaft are left hand thread 1 Flip lid open then move release lever to the up position 2 Take wrench 10mm and loose...

Страница 13: ...just gas flow per Setting Gas Flow Rate 7 Re engage wire drive by pushing release lever to down position to feed wire 8 Momentarily squeeze trigger and verify that wire feeds properly Trim wire to app...

Страница 14: ...8 9 Wire Size Metal Thickness Arc Volts Wire Speed Amps DC in mm ga in mm ipm mpm 030 0 8 22 030 0 8 13 14 1 200 5 1 40 20 036 1 0 13 14 1 240 6 1 40 18 048 1 2 14 15 1 290 7 4 50 16 060 1 6 15 16 1 3...

Страница 15: ...25 Thread on 550A Nozzle Tip Recessed Order KP2743 1 62RA Insulator For 550 Amp front end expendables Order KP2773 1 Contact Tips Both standard duty and heavy duty contact tips are available in a vari...

Страница 16: ...1 LOCATE PROBLEM SYMPTOM Look under the column labeled PROBLEM SYMPTOMS This column describes possible symptoms that the machine may exhibit Find the listing that best describes the symptom that the...

Страница 17: ...ler 1 Change position of wire drive roller 2 Wire drive release open 2 Close wire drive release 3 Wire welded to tip 3 Peel wire off tip or use new tip 4 Wire spool empty 4 Insert new spool 5 Tip too...

Страница 18: ...should vary from 5K 0 ohms TESTINg THE TRIggER SwITCH Using the torch Control Cable Connector check for continuity across pins E and F when the trigger is pressed 12 Observe all Safety Guidelines det...

Страница 19: ...ed 12 Test weld before adding blue loctite into the set screw hole at the trigger top red part FIGURE F 1 MECHANICAL vALvE REPLACEMENT 1 Remove the following items a Gun tube barrel b Plastic screw co...

Страница 20: ...This page intentionally left blank...

Страница 21: ...This page intentionally left blank...

Страница 22: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra...

Страница 23: ...d Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de ali mentac...

Страница 24: ...tomer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such information or...

Отзывы: