Lincoln Electric MAGNUM 550 Скачать руководство пользователя страница 2

FOR ENGINE
powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance

work unless the maintenance work requires it to be running.

____________________________________________________

1.b.Operate engines in open, well-ventilated

areas or vent the engine exhaust fumes
outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame

welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporiz-
ing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers

and devices in position and in good
repair.Keep hands, hair, clothing and tools
away from V-belts, gears, fans and all other
moving parts when starting, operating or
repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety

guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt

to override the governor or idler by pushing on the throttle
control rods while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while

turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.

i

SAFETY

i

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

WARNING

Mar ʻ95

ELECTRIC AND
MAGNETIC FIELDS
may be dangerous

2.a. Electric current flowing through any conductor causes

localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines

2.b. EMF fields may interfere with some pacemakers, and

welders having a pacemaker should consult their physician
before welding.

2.c. Exposure to EMF fields in welding may have other health

effects which are now not known.

2.d. All welders should use the following procedures in order to

minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure

them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and

work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as

possible to the area being welded.

2.d.5. Do not work next to welding power source.

1.h. To avoid scalding, do not remove the

radiator pressure cap when the engine is
hot.

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.

The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.

The Above For Diesel Engines

The Above For Gasoline Engines

Содержание MAGNUM 550

Страница 1: ...your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful IM475 A M...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...er for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both...

Страница 4: ...easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site sp...

Страница 5: ...i s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan t...

Страница 6: ...mportant when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on the...

Страница 7: ...ders A 6 Installation of Optional Gun Hanger A 6 __________________________________________________________________________________________ Operation Section B Electrodes and Equipment B 1 Making a We...

Страница 8: ...1 6mm KP16S 116 625 I D 12 Rec K598 8 25 ft 7 5m 052 1 3mm KP16S 52 KP56S SW KP26CT 62 KP36CT KP45 116 25 KP1951 1 1 16 1 6mm KP16S 116 625 I D 12 Rec K598 9 10 ft 3 0m 5 64 2 0mm KP16S 564 KP56S H KP...

Страница 9: ...ailable as a parts order With the trigger pulled in all the way the trigger can be slid forward into the interlock position To release interlock squeeze trigger and slide back The trigger is made of a...

Страница 10: ...plug and socket are keyed and must be properly oriented d Place one tubing clamp onto each end of the flexi ble tubing provided approximately 2 51mm in from each end Slide one end of the tubing onto...

Страница 11: ...s fitting provided in the kit c Attach the phone plug connector of the gun con trol cable provided to the trigger connector on the front of the Hobart feeder d Place one tubing clamp onto each end of...

Страница 12: ...ect easily to a variety of popular Miller wire feeders a Check that the gun liner connector cap liner drive roll s and guide tubes are appropriate for the electrode size being used For K613 3 and K613...

Страница 13: ...aterial are included in each kit b Fully push the brass connector end of the gun and cable into the connector receptacle on the outgoing side of the feeder wire drive Tighten the hand screw to clamp d...

Страница 14: ...ck Avoiding Wire Feeding Problems Wire feeding problems can be avoided by observing the following gun handling procedures a Do not kink or pull cable around sharp corners b Keep the electrode cable as...

Страница 15: ...16 4 8mm Allen wrench Remove coarse thread nozzle and coarse thread insulator assembly Pull gun tube out from gun handle To reinstall insert the gun tube push in as far as possible and retighten screw...

Страница 16: ...nsert a 250 6 4mm diameter rod through the connector and into core of cable approximately 5 00 127mm when push ing the connector tube into the cable core tube To tighten hold the connector in place wh...

Страница 17: ...ip the connector nut over the copper strands with the threaded end out Assemble incoming connector to cable by forcing the steel tube of the connector into the inside diameter of the cable inner tube...

Страница 18: ...7 X 2 M12 X 1 5 THREAD SIZES FOR K598 1 thru 14 MAGNUM 550 CONSUMABLES USED WITH An KP1951 1 or 2 Gun Tube Tweco NO 6 8 32 5 8 18 7 16 20 5 16 24 THREAD SIZES FOR K598 15 thru 18 MAGNUM 550 CONSUMABLE...

Страница 19: ...contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause If you do not understand or are unable to perform the Recommended C...

Страница 20: ...rent and or duty cycle welding a Keep as straight as possible Inspect cable and replace if necessary b Remove wire from gun and cable feed in new wire Note any obstruc tion Replace liner if necessary...

Страница 21: ...NOTES MAGNUM 550...

Страница 22: ...NOTES MAGNUM 550...

Страница 23: ...parts or electrode with skin or wet clothing G Insulate yourself from work and ground G No toque las partes o los electrodos bajo carga con la piel o ropa moja da G Aislese del trabajo y de la tierra...

Страница 24: ...nd Entl ftung des Arbeitsplatzes G Mantenha seu rosto da fuma a G Use ventila o e exhaust o para remover fumo da zona respirat ria G Turn power off before servicing G Desconectar el cable de ali menta...

Страница 25: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: