Lincoln Electric MAGNUM 550 Скачать руководство пользователя страница 15

D-1

MAINTENANCE

D-1

MAINTENANCE

Removal, Installation and Trimming Instructions
for MAGNUM® Liners

NOTICE: 

The variation in cable lengths prevents the

interchangeability of liners. Once a liner has been cut
for a particular gun, it should not be installed in anoth-
er gun, unless it can meet the liner cut off length
requirement. Liners are shipped with the jacket of the
liner extended the proper amount.

a.

Remove the gas nozzle and nozzle insulator.
Loosen the set screw located in the side of the
handle or in the diffuser with 5/64” (2.0mm) Allen
wrench (provided with the gun or Connector Kit).

b.

Remove the gas diffuser from gun.

c.

Lay gun and cable out straight on a flat surface.

For K613-1 K613-2, K613-5 and K613-6 connections:

Loosen set screw located in the brass cable con-
nector at the wire feeder end of the cable using
the same 5/64” (2.0mm) Allen wrench. Pull liner
out of cable. (Refer to Figure 1).

OR

For K613-3 and K613-4 connections:

Remove the connector cap. Remove gun tube
and tap on end of liner to expose liner bushing on
wire feeder end of cable. Pull liner out of cable. If
the liner is going to be replaced with a different
size liner, loosen set screw on the connector cap
and remove piece of liner material.

d.

For installation and trimming instructions for MAG-
NUM® liners, see Liner Installation and Trimming
Instructions. 

Gun Tubes and Nozzles

a.

Replace worn contact tips as required.

b.

Remove spatter from inside of gas nozzle and
from tip after each 10 minutes of arc time or as
required.

c.

To remove gun tube from gun, loosen socket-
head clamping screw in handle with 3/16”
(4.8mm) Allen wrench. Remove coarse thread
nozzle and coarse thread insulator assembly.

Pull gun tube out from gun handle. To reinstall,
insert the gun tube, push in as far as possible,
and retighten screw.

GUN CABLES

Cable Cleaning

Clean cable liner after using approximately 300 lbs
(136 kg) of electrode. Remove the cable from the wire
feeder and lay it out straight on the floor. Remove the
contact tip from the gun. Using an air hose and only
partial pressure, gently blow out the cable liner from
the gas diffuser end.

Cable Repair

The MAGNUM® 550 guns feature the use of
repairable cable connectors. If the cable ever gets
severely damaged, it may be cut shorter and repaired
by the user. Repair cables as follows:

Gun Tube End Repair 

(Requires 2 No. S19492-2

Terminals
a.

Remove the cable liner per Removal, Installation
and Trimming Instructions.

b.

Remove the gun tube per section entitled “Gun
Tubes and Nozzles”.

c.

Remove four #6 screws from the gun handle, sep-
arate the two halves, and remove the cable from
the handle along with the trigger assembly.

d.

Remove gun tube connector from cable by
unscrewing connector nut from gun tube connec-
tor. If the cable inner tube is difficult to remove
from the connector assembly, carefully slit it
lengthwise with a knife up to the brass connector.

MAGNUM® 550

ELECTRIC SHOCK

can kill.

• Have a qualified individual install
and service this equipment.

• Turn the input power for the power

source off at the fuse box or disconnect switch
before working on this equipment.

•  Do not touch electrically hot parts such as out-

put terminals or internal wiring.

----------------------------------------------------------------------

WARNING

Excessive pressure at the start may cause the dirt
to form a plug.

Flex the cable over its entire length and again
blow out the cable. Repeat this procedure until no
further dirt comes out.

------------------------------------------------------------------

CAUTION

Содержание MAGNUM 550

Страница 1: ...your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful IM475 A M...

Страница 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Страница 3: ...er for cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both...

Страница 4: ...easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site sp...

Страница 5: ...i s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan t...

Страница 6: ...mportant when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on the...

Страница 7: ...ders A 6 Installation of Optional Gun Hanger A 6 __________________________________________________________________________________________ Operation Section B Electrodes and Equipment B 1 Making a We...

Страница 8: ...1 6mm KP16S 116 625 I D 12 Rec K598 8 25 ft 7 5m 052 1 3mm KP16S 52 KP56S SW KP26CT 62 KP36CT KP45 116 25 KP1951 1 1 16 1 6mm KP16S 116 625 I D 12 Rec K598 9 10 ft 3 0m 5 64 2 0mm KP16S 564 KP56S H KP...

Страница 9: ...ailable as a parts order With the trigger pulled in all the way the trigger can be slid forward into the interlock position To release interlock squeeze trigger and slide back The trigger is made of a...

Страница 10: ...plug and socket are keyed and must be properly oriented d Place one tubing clamp onto each end of the flexi ble tubing provided approximately 2 51mm in from each end Slide one end of the tubing onto...

Страница 11: ...s fitting provided in the kit c Attach the phone plug connector of the gun con trol cable provided to the trigger connector on the front of the Hobart feeder d Place one tubing clamp onto each end of...

Страница 12: ...ect easily to a variety of popular Miller wire feeders a Check that the gun liner connector cap liner drive roll s and guide tubes are appropriate for the electrode size being used For K613 3 and K613...

Страница 13: ...aterial are included in each kit b Fully push the brass connector end of the gun and cable into the connector receptacle on the outgoing side of the feeder wire drive Tighten the hand screw to clamp d...

Страница 14: ...ck Avoiding Wire Feeding Problems Wire feeding problems can be avoided by observing the following gun handling procedures a Do not kink or pull cable around sharp corners b Keep the electrode cable as...

Страница 15: ...16 4 8mm Allen wrench Remove coarse thread nozzle and coarse thread insulator assembly Pull gun tube out from gun handle To reinstall insert the gun tube push in as far as possible and retighten screw...

Страница 16: ...nsert a 250 6 4mm diameter rod through the connector and into core of cable approximately 5 00 127mm when push ing the connector tube into the cable core tube To tighten hold the connector in place wh...

Страница 17: ...ip the connector nut over the copper strands with the threaded end out Assemble incoming connector to cable by forcing the steel tube of the connector into the inside diameter of the cable inner tube...

Страница 18: ...7 X 2 M12 X 1 5 THREAD SIZES FOR K598 1 thru 14 MAGNUM 550 CONSUMABLES USED WITH An KP1951 1 or 2 Gun Tube Tweco NO 6 8 32 5 8 18 7 16 20 5 16 24 THREAD SIZES FOR K598 15 thru 18 MAGNUM 550 CONSUMABLE...

Страница 19: ...contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause If you do not understand or are unable to perform the Recommended C...

Страница 20: ...rent and or duty cycle welding a Keep as straight as possible Inspect cable and replace if necessary b Remove wire from gun and cable feed in new wire Note any obstruc tion Replace liner if necessary...

Страница 21: ...NOTES MAGNUM 550...

Страница 22: ...NOTES MAGNUM 550...

Страница 23: ...parts or electrode with skin or wet clothing G Insulate yourself from work and ground G No toque las partes o los electrodos bajo carga con la piel o ropa moja da G Aislese del trabajo y de la tierra...

Страница 24: ...nd Entl ftung des Arbeitsplatzes G Mantenha seu rosto da fuma a G Use ventila o e exhaust o para remover fumo da zona respirat ria G Turn power off before servicing G Desconectar el cable de ali menta...

Страница 25: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: