CYLINDER MAY EXPLODE IF DAMAGED:  Use only compressed gas cylinders containing the 
correct shielding gas for the process used and properly operating regulators designed for the gas and 
pressure used.  Always keep cylinders in an upright position securely chained to a fixed support.  Do 
not move or transport gas cylinders with the protection cap removed.  Do not allow the electrode, 
electrode holder, work clamp or any other electrically live part to touch a gas cylinder.  Gas cylinders 
must be located away from areas where they may be subjected to physical damage or the welding 
process including sparks and heat sources. 

 

Installation and Operator Instructions 

Read this entire section before installation or operation 
of the machine. 
 

Location and Environment 

This machine will operate in harsh environments.  
However, it is important that simple preventative 
measures are followed to assure long life and reliable 
operation. 
 

 

Do not place or operate this machine on a surface 
with an incline greater than 15° from horizontal. 

 

Do not use this machine for pipe thawing. 

 

This machine must be located where there is free 
circulation of clean air without restrictions for air 
movement to and from the air vents.  Do not cover 
the machine with paper, cloth or rags when 
switched on. 

 

Dirt and dust that can be drawn into the machine 
should be kept to a minimum. 

 

This machine has a protection rating of IP23.  Keep 
it dry when possible and do not place it on wet 
ground or in puddles. 

 

Locate the machine away from radio controlled 
machinery.  Normal operation may adversely affect 
the operation of nearby radio controlled machinery, 
which may result in injury or equipment damage.  
Read the section on electromagnetic compatibility 
in this manual. 

 

Do not operate in areas with an ambient 
temperature greater than 40°C. 

 

Duty cycle 

The duty cycle of a welding machine is the percentage 
of time in a 10 minute cycle at which the welder can 
operate the machine at rated welding current. 
 
Example: 60% duty cycle: 

 

Welding for 6 minutes. 

Break for 4 minutes. 

 
Refer to the Technical Specification section for more 
information about the machine rated duty cycles. 
 

Input Supply Connection 

Check the input voltage, phase, and frequency of the 
power source that will be connected to this wire feeder. 
The allowable input voltage of the power source is 
indicated on the rating plate of the wire feeder.  Verify 
the connection of grounding wires from the power 
source to the input source. 
 

Gas Connection 

A gas cylinder must to be installed with a proper flow 

regulator.  Once a gas cylinder with a flow regulator has 
been securely installed, connect the gas hose from the 
regulator to the machine gas inlet connector.  Refer to 
point 8 of the images below.  The wire feeder supports 
all suitable shielding gases including carbon dioxide, 
argon and helium at a maximum pressure of 5,0 bar. 
 
The Linc Feed also includes an internal gas flow 
regulator, showed at point 11 of the images below. 
 

Output Connections 

Refer to item 3 of the images below. 
 

Controls and Operational Features 

 

 

 
1.  Water Connectors:  Connections for water cooled 

torches. 

 

Warm water from torch. 

 

 

Cool water to torch. 

 

 
2.  Remote Control Receptacle:  If a remote 

control is used, it will be connected to the 
remote receptacle. 

 
3.  Euroconnector:  Connect welding torches. 
 
4.  Digital Display Interface:  Control of welding 

parameters including Wire Feed Speed, Voltage, 
and Memory Recall.  See sections A-G for further 
details. 

 

English  

English 

Содержание LINC FEED 37

Страница 1: ...IM1094 09 2016 REV08 LINC FEED 37 38 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Страница 2: ...LINC FEED 38 conforms to the following directives 2014 35 EU 2014 30 EU and has been designed in compliance with the following standards EN 60974 5 2013 EN 60974 10 2014 20 04 2016 Piotr Spytek Operat...

Страница 3: ...ture reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purch...

Страница 4: ...clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may...

Страница 5: ...may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Duty cycle The duty cyc...

Страница 6: ...or Lincoln Electric Maintenance or repairs performed by unauthorized service centers or personnel will null and void the manufacturer s warranty The frequency of the maintenance operations may vary i...

Страница 7: ...Mode LF 38 While pressing the Prog button rotate the left knob until NON SYNERGIC appears on the display Before Welding Pre Set Pre Set Wire Feed Speed Meters Minute Adjust with left knob Pre Set Weld...

Страница 8: ...select the appropriate wire diameter Steel 80 20 0 8 1 0 1 2 mm Stainless 98 2 0 8 1 0 1 2 mm Metal Cored 98 2 1 2 1 6 mm Flux Cored 80 20 1 2 1 6 mm Flux Cored CO2 1 2 1 6 mm AlMg 100 Arg 1 2 1 6 mm...

Страница 9: ...hape at the end of the weld NO YES 4 Strokes 4 Strokes Crater WFS Welding WFS m min Crater Voltage Welding Voltage Volts Hot Soft Start WFS Allows to set higher or lower welding parameters to improve...

Страница 10: ...arameters into the selected memory WRITE into memory The status of the memory becomes Used READ You can read the welding parameters allready saved into the selected memory ERASE memory If you confirm...

Страница 11: ...ns Only the memory locations that have been used will be available Once selected begin welding Welding While welding in Memory Mode the Non Synergic Voltage or the Synergic Trim values can be varied a...

Страница 12: ...ton Enter Lock Or Unlock NO Confirm NO to Exit this menu YES Confirm YES to Enter the menu Lock Or Unlock Select 1 st Digit of your code Confirm 1st Digit Select 2 nd Digit of your code Confirm 2 nd D...

Страница 13: ...dard value 2 Value used to determine the acceleration of the wire between the Cold inch WFS and the Welding WFS PRODUCT TYPE Not used Shows Product Type LF 37 or LF 38 SN Not used Shows Product Serial...

Страница 14: ...mote position Reduce the parameters or use an higher rating generator Wire Feed Jam Motor is at maximum power and is not able to maintain the pre set WFS value Verify wire can move freely in cable Ver...

Страница 15: ...be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction of the area and other...

Страница 16: ...e Use only the parts marked X in the column under the heading number called for in the assembly page indicate a change in this printing First read the Part List reading instructions above then refer t...