English
English
17
Sense From Studs -
Use this option for diagnostic purposes
only. When power is cycled, this option is automatically reset
to False.
"No" = Voltage sensing is automatically determined by the
selected weld mode and other machine settings.
"Yes" = Voltage sensing is forced to "studs" of the power
source.
Note:
This option may not be available on all machines. The
power source must support this functionality, or this option will
not appear in the menu.
Brightness Control
- enables the brightness level.
Adjust range: from 1 to +10, where 5 is default.
Restore Factory Settings
– to restore Factory Settings:
Use the right button to confirm the selection.
Use the right control to select "YES".
Use the right button to confirm the selection.
Note:
After the device has been restarted the P097 is "NO".
Show Test Modes
– uses for calibration and tests. To use the
Test Modes:
On the right display is shown "LOAD".
Use the right button to confirm the selection.
On the right display is shown "DONE"
Note:
After the device has been restarted the P099 is "LOAD".
View Software Version Info
– used for viewing the software
versions for user interface.
To read the software version:
In Advanced Menu select P103.
Confirm the selection, push the right button.
The displays will show the software version.
Note:
P103 is a diagnostic parameter, to read only.