![Lincoln Electric K14138-1 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/lincoln-electric/k14138-1/k14138-1_operators-manual_1919105040.webp)
English
English
37
UltimArc™
– for pulse welding adjusts the focus or
shape of the arc. In consequence of increasing
UltimArc™ Control value the arc is tight, stiff for high
speed sheet metal welding.
Adjust range: from -10 to +10
Factory default, UltimArc™ is OFF.
M
-10.0
10.0
OFF
OFF
Figure 77
1
2
3
Figure 78
1. UltimArc™ Control "-10.0": Low Frequency, Wide.
2. UltimArc™ Control OFF: Medium Frequency and
Width.
3. UltimArc™ Control "+10.0": High Frequency,
Focused.