![Lincoln Electric K14138-1 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/lincoln-electric/k14138-1/k14138-1_operators-manual_1919105018.webp)
English
English
15
1.5s
min
m
10.00
v
31.6
t1
t2
Figure 26
A/B procedure (PF46 only)
enables quick
weld procedure change. The sequence
changes may occur between:
Two different welding programs.
Different settings for the same program.
User Memory (PF46 only)
enables:
Store the welding programs to one of the
nine user memory.
Recall the stored programs from the user
memory
To store the Welding Program to the User Memory:
Add the User Memory icon to the Welding
Parameters Bar [27].
Use the Set Control [11] to highlight the User
Memory icon.
125
A
22.5
V
1.2
Steel
ArCO2
21
M
M
v
28.6
min
m
5.51
Figure 27
Press the Set Control [11] – the User Memory Menu
is shown on the display.
Use the Set Control [11] to highlight the Save to the
Memory icon.
M
M
Figure 29
Press the Set Control [11].
Use the Set Control [11] to highlight the Memory
Number where the program would be stored.
Confirm the select – press the Right Button [12].
To recall the Welding Program from The User Memory:
Note:
Before using, the Welding Program had to be
assigned to the user memory
Add the User Memory icon to the Welding
Parameters Bar [27].
Use the Set Control [11] to highlight the User
Memory icon.
Press the Set Control [11] – the User Memory Menu
is shown on the display.
Use the Set Control [11] to highlight the Recall to the
Memory icon.
M
M
Figure 29
Press the Set Control [11].
Use the Set Control [11] to highlight the Memory
Number which from the Welding Program will be
recall.
Confirm the select – press the Right Button [12].
Note:
If the parameters saved in the program memory
are highlighted on red (figure 30) it means that the unit of
the workpoint and/or trim in Setup Menu is not the same
as the unit of these parameters saved in the program
memory. In that case, after the welding program is
recalled, the parameters marked on red will be changed.
To restore the units compliances, enter to Setup Menu
and set the parameters P028 and/or P020 accordingly.