Lincoln Electric K14110-1 Скачать руководство пользователя страница 32

English  

English 

29 

 

Roll Kit For Solid Wires 

KP14150-V06/08 

ROLL KIT 0.6/0.8VT FI37 4PCS GREEN/BLUE 

KP14150-V08/10 

ROLL KIT 0.8/1.0VT FI37 4PCS BLUE/RED 

KP14150-V10/12 

ROLL KIT 1.0/1.2VT FI37 4PCS RED/ORANGE 

KP14150-V12/16 

ROLL KIT 1.2/1.6VT FI37 4PCS ORANGE/YELL 

KP14150-V16/24 

ROLL KIT 1.6/2.4VT FI37 4PCS YELL/GREY 

KP14150-V09/11 

ROLL KIT 0.9/1.1VT FI37 4PCS 

KP14150-V14/20 

ROLL KIT 1.4/2.0VT FI37 4PCS 

Roll Kit For Aluminium Wires 

KP14150-U06/08A

 

ROLL KIT 0.6/0.8AT FI37 4PCS GREEN/BLUE 

KP14150-U08/10A

 

ROLL KIT 0.8/1.0AT FI37 4PCS BLUE/RED 

KP14150-U10/12A

 

ROLL KIT 1.0/1.2AT FI37 4PCS RED/ORANGE 

KP14150-U12/16A

 

ROLL KIT 1.2/1.6AT FI37 4PCS ORANGE/YELL 

KP14150-U16/24A

 

ROLL KIT 1.6/2.4AT FI37 4PCS YELL/GREY 

Roll Kit For Cored Wires 

KP14150-V12/16R 

ROLL KIT 1.2/1.6RT FI37 4PCS ORANGE/YELL 

KP14150-V14/20R 

ROLL KIT 1.4/2.0RT FI37 4PCS 

KP14150-V16/24R 

ROLL KIT 1.6/2.4RT FI37 4PCS YELL/GREY 

KP14150-V09/11R 

ROLL KIT 0.9/1.1RT FI37 4PCS 

KP14150-V10/12R 

ROLL KIT 1.0/1.2RT FI37 4PCS -/ORANGE 

Wire Guides 

0744-000-318R 

Wire Guide Set Blue ø0.6-1.6 

0744-000-319R 

Wire Guide Set Red ø1.8-2.8 

R-2013-161-1R 

Euro Wire Guide ø0.6-1.6 

R-2013-167-1R 

Euro Wire Guide ø1.8-2.8 

LINC GUN

TM

 

K10413-36 

Gas cooled gun LG 360 G (335A 60%) 

– 3m, 4m, 5m. 

K10413-42 

Gas cooled gun LG 420 G (380A 60%) 

– 3m, 4m, 5m. 

K10413-410 

Water cooled gun LG 410 W (350A 100%) - 3m, 4m, 5m. 

K10413-500 

Water cooled gun LG 500 W (450A 100%) - 3m, 4m, 5m. 

K10413-36PHD-xM 

Gas cooled gun LGP 360 G (300A@60%) - 3m, 4m, 5m 

K10413-42PHD-xM 

Gas cooled gun LGP 420 G (350A@60%) - 3m, 4m, 5m 

K10413-55PHD-xM 

Water cooled gun LGP 550 W (500A@100%) - 3m, 4m, 5m 

K10413-ALUPHD-4M 

Water cooled gun LGP S2F ALU (500A@100%) 4m 

K10429-36-Xm 

Gas cooled gun LGS 360 G (320A@60%) - 3m, 4m, 5m 

K10429-505-xM 

Water cooled gun LGS 505 W (450A@100%) - 3m, 4m, 5m 

K10413-PPW405-8M 

Water cooled Push-Pull gun LG PPLG405WC (350A@100%) 8m 

K115-1 

Innershield

®

 

gun 450A@60% 82° - 3m 

K115-2 

Innershield

®

 gun 450A@60% 

82° - 4,5m 

K126-1 

Innershield

®

 

gun 350A@60% 62° - 3m 

K126-2 

Innershield

®

 

gun 350A@60% 62° - 4,5m 

K10343 

Innershield

®

 gun adaptor 

Содержание K14110-1

Страница 1: ...IM3046 06 2016 REV01 PF22 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Страница 2: ...ne K14110 1 PF 22 conforms to the following directives 2014 35 EU 2014 30 EU and has been designed in compliance with the following standards EN 60974 5 2013 EN 60974 10 2014 20 04 2016 Piotr Spytek O...

Страница 3: ...t Supply Connection 5 Controls and Operational Features 5 User Panel 6 Welding Process Change 7 The assignment of the weld program to the user memory 8 Welding Parameters 8 Crater 8 Wave Controls 9 Se...

Страница 4: ...g Current Range Peak Open Circuit Voltage 5 500A 113Vdc or Vac peak DIMENSION Weight Height Width Length 14 8 kg 380 mm 220 mm 590 mm WIRE FEED SPEED RANGE WIRE DIAMETER WFS Range Drive Rolls Drive ro...

Страница 5: ...surement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in t...

Страница 6: ...l electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do not place the elect...

Страница 7: ...anufacturer reserves the right to make changes and or improvements in design without upgrade at the same time the operator s manual Introduction PF 22 is digital wire feeder which has been designed to...

Страница 8: ...t This connector allows connection Remote Control See Accessories chapter 5 Output Socket for the Welding Circuit For connecting an electrode holder with lead 6 User Panel see the section dedicated 7...

Страница 9: ...pts Readi Reel type spools onto included spindle adapter 18 Wire Drive 4 Roll wire drive WARNING The wire drive door has to be completely closed during welding WARNING Not use handle to move the machi...

Страница 10: ...lding parameters Crater Wave Controls 28 LED Indicator Indicates that the Settings and Configuration Menu is activated 29 Left Button Enables Checking the program number assigned to active memory To c...

Страница 11: ...ater Procedure controls the WFS value in ampere units and Volts Trim for a specified time at the end of the weld after the trigger is released During the Crater time the machine will ramp up or down f...

Страница 12: ...The Menu cannot be accessed if the system is welding or if there is a fault status LED is not solid green Parameter Selection Mode the Parameter Name on the Left Display 19 blinking Parameter Change V...

Страница 13: ...he Welding Parameters Advanced Level advanced menu configure device menu Note The availability parameters 19 in the Setting and Configuration Menu depend on the selected welding program welding proces...

Страница 14: ...after the welding output turns off Factory default Postflow Time is set at 2 5 seconds Adjust range from 0 seconds to 25 seconds Spot Timer adjusts the time welding will continue even if the trigger i...

Страница 15: ...tomatically TIG Use this setting while TIG welding with a foot or hand current control device Amptrol While TIG welding the upper left Control on the User Interface sets the maximum current obtained w...

Страница 16: ...hange is not possible Display Workpoint as Amps Option determines how workpoint is displayed No factory default the workpoint is displayed in the format defined in the weld set Yes all workpoint value...

Страница 17: ...Test Modes On the Right display is shown LOAD Use the Right Button to confirm the selection On the Right display is shown DONE Note After the device has been restarted the P099 is LOAD View Software V...

Страница 18: ...Mode Select Panel all others Mode Select Panel settings are unlocked Wave Control Options Locked The Wave Control parameters on the Mode Select Panel are locked all others are unlocked Start End Wave...

Страница 19: ...e SMAW welding program 1 2 or 4 Note The list of available programs depends on the power source Set the welding parameters The welding machine is now ready to weld By applying the principle of occupat...

Страница 20: ...piece with the electrode and lifting it by a few millimeters contact ignition and lift ignition By applying the principle of occupational health and safety at welding welding can be begun For 3 progra...

Страница 21: ...be ready to work with the power source Status LED 20 stops blinking and lights steady green light Insert the wire into the welding gun WARNING Keep the gun cable as straight as possible when loading e...

Страница 22: ...the program had to be assigned to the user memory Note The list of available programs depends on the power source If it is needed the welding voltage can be adjusted by the Right Control 24 When the R...

Страница 23: ...d 32 is the main control parameter As the Wire Feed Speed is adjusted the power source adjusts the waveform parameters to maintain good welding characteristics Trim 24 is used as a secondary control t...

Страница 24: ...to 1 50 1 00 is the nominal setting Figure 14 Increasing the Trim value increases the arc length Decreasing the Trim value decreases the arc length Figure 15 When Trim is adjusted the power source aut...

Страница 25: ...parts with poor fit up During STT welding sense lead has to be connected to the workpiece Welding STT in non synergic mode Manually can set Wire Feed Speed WFS 32 Burnback Time Run in WFS Preflow Tim...

Страница 26: ...timArc Control OFF Medium Frequency and Width 3 UltimArc Control 10 0 High Frequency Focused Wire Spool Loading Wire spool type S300 and BS300 can be installed on the wire spool support without adapte...

Страница 27: ...Make sure that the locking nut is tightened Wire Spool Type B300 Loading WARNING Turn the input power OFF at the welding power source before installation or changing a wire spool Figure 23 Turn the in...

Страница 28: ...rew the locking nut of the sleeve Load the spooled wire on the sleeve such that the spool turns clockwise when the wire is fed into the wire feeder Make sure that the spindle brake pin 38 goes into th...

Страница 29: ...the wire comes out of the threaded end Or the Cold Inch Gas Purge Switch 15 can be used keep in Cold Inch position until the wire comes out of the threaded end When trigger or the Cold Inch Gas Purge...

Страница 30: ...Maintenance WARNING For any repair operations modifications or maintenance it is recommended to contact the nearest Technical Service Center or Lincoln Electric Repairs and modifications performed by...

Страница 31: ...then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference Electrical Schematic Refer to the Spare Part manual supplied with the mac...

Страница 32: ...KP14150 V09 11R ROLL KIT 0 9 1 1RT FI37 4PCS KP14150 V10 12R ROLL KIT 1 0 1 2RT FI37 4PCS ORANGE Wire Guides 0744 000 318R Wire Guide Set Blue 0 6 1 6 0744 000 319R Wire Guide Set Red 1 8 2 8 R 2013...

Страница 33: ...English English 30 Connection Diagram K1412 1 2 K1412 1 3 K1412 1 6 K14110 1 PF22 K10348 PGW XXM 9 K10348 PG XXM K1034 PGW XXM K1034 PG XXM 9 K14110 1 PF22 POWER SOURCE...

Страница 34: ...English English 31...

Страница 35: ...English English 32...